Datalogic PowerScan PD830 Handleiding

Datalogic Barcode lezer   PowerScan PD830

Lees hieronder de 📖 handleiding in het Nederlandse voor Datalogic PowerScan PD830 (2 pagina's) in de categorie Barcode lezer  . Deze handleiding was nuttig voor 40 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
Datalogic Scanning, Inc.
959 Terry Street
Eugene, Oregon 97402
USA
Telephone: (541) 683-5700
Fax: (541) 345-7140
An Unpublished Work - All rights reserved. No part of the contents of this documentation or the
procedures described therein may be reproduced or transmitted in any form or by any means without
prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" o
r
“Datalogic Scanning”). Owners of Datalogic products are hereby granted a non-exclusive, revocable
license to reproduce and transmit this documentation for the purchaser's own internal business purposes.
Purchaser shall not remove or alter any proprietary notices, including copyright notices, contained in this
documentation and shall ensure that all notices appear on any reproductions of the documentation.
Should future revisions of this manual be published, you can acquire printed versions by contacting you
r
Datalogic representative. Electronic versions may either be downloadable from the Datalogic website
(www.scanning.datalogic.com) or provided on appropriate media. If you visit our website and would like to
make comments or suggestions about this or other Datalogic publications, please let us know via the
"Contact Datalogic" page.
DISCLAIMER
Datalogic has taken reasonable measures to provide information in this manual that is complete and
accurate, however, Datalogic reserves the right to change any specification at any time without prio
r
notice. Datalogic is a registered trademark of Datalogic S.p.A. in many countries and the Datalogic logo is
a trademark of Datalogic S.p.A. all licensed to Datalogic Scanning, Inc. All other trademarks and trade
names referred to herein are property of their respective owners.
SERVICE AND SUPPORT
Datalogic provides several services as well as technical support through its website. Log on to
www.scanning.datalogic.com and click on the links indicated for further information including:
PRODUCTS
Search through the links to arrive at your product page where you can download specific Manuals
and Software & Utilities including:
- Datalogic Aladdin™, a multi-platform utility program that allows device configuration using a
PC. It provides RS-232 interface configuration as well as configuration barcode printing.
SERVICE & SUPPORT
- Technical Support - Product documentation and programming guides and Technical Support
Department in the world
- Service Programs - Warranty Extensions and Maintenance Agreements
- Repair Services - Flat Rate Repairs and Return Material Authorization (RMA) Repairs.
- Downloads – Manuals & Documentation, Data Sheets, Product Catalogues, etc.
CONTACT US
Information Request Form and Sales & Service Network
WARRANTY
Datalogic warranties this product against defects in workmanship and materials, for a period of 3 years
from the date of shipment, provided that the product is operated under normal and proper conditions.
Datalogic has the faculty to repair or replace the product; these provisions do not prolong the original
warranty term.
The warranty does not apply to any product that has been subject to misuse, accidental damage,
unauthorized repair or tampering.
Datalogic Scanning, Inc.
959 Terry Street
Eugene, OR 97402
USA 07
dichiara che
declares that the
clare que le
bescheinigt, daß das Gerät
declare que el
POWERSCAN Dxxx
e tutti i suoi modelli
and all its models
et tous ses modèles
und seine Modelle
y todos sus modelos
sono conformi alle Direttive del Consiglio Europeo sottoelencate:
are in conformity with the requirements of the European Council Directives listed below:
sont conformes aux spécifications des Directives de l'Union Euroenne ci-dessous:
den nachstehenden angeführten Direktiven des Europäischen Rats:
cumple con los requisitos de las Directivas del Consejo Europeo, según la lista siguiente:
89/336/EEC EMC Directive e 92/31/EEC, 93/68/EEC emendamenti successivi
and further amendments
et ses successifs amendements
und späteren Abänderungen
y succesivas enmiendas
Basate sulle legislazioni degli Stati membri in relazione alla compatibilità elettromagnetica ed alla sicurezza dei
prodotti.
On the approximation of the laws of Member States relating to electromagnetic compatibility and product safety.
Basée sur la législation des Etats membres relative à la compatibilité électromagnétique et à la sécuri des
produits.
Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Verträglichkeit und
Produktsicherheit entsprechen.
Basado en la aproximación de las leyes de los Países Miembros respecto a la compatibilidad electromagnética y
las Medidas de seguridad relativas al producto.
Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti:
This declaration is based upon compliance of the products to the following standards:
Cette déclaration repose sur la conformité des produits aux normes suivantes:
Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht:
Esta declaración se basa en el cumplimiento de los productos con las siguientes normas:
EN 55022 (C
LASS
A ITE), August 1994:
AMENDMENT A1 (CLASS A ITE), October 2000:
LIMITS AND METHODS OF MEASUREMENTS OF RADIO
DISTURBANCE CHARACTERISTICS OF INFORMATION
TECHNOLOGY EQUIPMENT
EN 61000-6-2, October 2001: ELECTROMAGNETIC COMPATIBILITY (EMC).
PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL
ENVIRONMENTS.
March 1st, 2007
PowerScan® D8330
READERS
QUICK REFERENCE GUIDE
820001940 (Rev. D) 02/08
UPDATES AND LANGUAGE AVAILABILITY
UK/US
The latest drivers and documentation updates for this product are available on
Internet.
Log on to: www.scanning.datalogic.com
I
Su Internet sono disponibili le versioni aggiornate di driver e documentazione di
questo prodotto. Questo manuale è disponibile anche nella versione italiana.
Collegarsi a: www.scanning.datalogic.com
F
Les versions mises à jour de drivers et documentation de ce produit sont
disponibles sur Internet. Ce manuel est aussi disponible en version française.
Cliquez sur : www.scanning.datalogic.com
D
Im Internet finden Sie die aktuellsten Versionen der Treiber und Dokumentation für
dieses Produkt. Die deutschsprachige Version dieses Handbuches ist auch
verfügbar.
Adresse : www.scanning.datalogic.com
E
En Internet están disponibles las versiones actualizadas de los drivers y
documentación de este producto. También está disponible la versión en español
de este manual.
Dirección Internet : www.scanning.datalogic.com
CONNECTIONS
CONNECTING THE CABLE
A. Rubber gasket
B. Plastic boot
C. Cable spacer
D. Cover
E. Strain relief
c
c
c
cc Slip the cover over the
cable.
d
d
d
dd Push the plastic boot into
the rubber gasket. Take
care that the tab on the
plastic boot is aligned with
the notch in the rubber
gasket.
e
e
e
ee Push the plastic boot and
gasket into the handle.
Ensure that the “Front”
marking on the plastic boot
is facing out, with the
arrow .pointing towards
the front of the scanner.
f
f
f
ff Insert the cable into the
socket of the plastic boot.
g
g
g
gg Insert the cable spacer
into the cable wire and
slide it towards the handle.
h
h
h
hh Push the cover along the
cable towards the reader,
and hook it over the yellow
“tooth”.
i
i
i
ii Insert the strain relief into
the cover and tighten the
screw to fix the whole
assembly to the reader
handle.
COMPLIANCE
LASER SAFETY COMPLIANCE
The laser scanner conforms to the applicable requirements of both CDRH 21 CFR 1040 and
EN60825-1 at the date of manufacture.
The laser light is visible to the human eye and is emitted
from the output window c.
Laser warning and classification label d.
CAUTION:
Use of controls or adjustments or performance o
f
procedures other than those specified herein may result in
exposure to hazardous visible laser light.
The laser scanner utilizes a low-power laser diode. Although staring directly at the laser beam
momentarily causes no known biological damage, avoid staring at the beam as one would with
any very strong light source, such as the sun. Avoid that the laser beam hits the eye of an
observer, even through reflective surfaces such as mirrors, etc.
The following information is shown on the laser scanner device class label:
LASER LIGHT - DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT
MAX. OUTPUT RADIATION 1.4 mW
EMITTED WAVELENGTH 630~680 nm
EN60825-1: 2001
CAUTION - CLASS 2 LASER
LIGHT WHEN OPEN
AVOID EXPOSURE – LASER LIGHT
IS EMITTED FROM THIS APERTURE
DO NOT STARE INTO BEAM
This product complies with
21 CFR Subchapter J
ITALIANO LUCE LASER
NON FISSARE IL RAGGIO
APPARECCHIO LASER DI CLASSE 2
FRANÇAIS RAYON LASER
EVITER DE REGARDER LE RAYON
APPAREIL LASER DE CLASSE 2
DEUTSCH LASERSTRAHLUNG
NICHT IN DEN STRAHL BLICKEN
PRODUKT DER LASERKLASSE 2
ESPAÑOL RAYO LÁSER
NO MIRAR FIJO EL RAYO
APARATO LÁSERDE CLASE 2
LED CLASS
Class 1 LED product.
This product conforms to EN60825-1:2001.
USB
WEDGE
RS-232
PEN
CE COMPLIANCE
Warning:
This is a Class A product. In a domestic environment this product may cause radio interference
in which case the user may be required to take adequate measures.
FCC COMPLIANCE
Modifications or changes to this equipment without the expressed written approval of Datalogic
could void the authority to use the equipment.
This device complies with PART 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accep
t
any interference received, including interference which may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, i
f
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely
to cause harmful interference in which case the user will be required to correct the interference
at his own expense.
POWER SUPPLY
This device is intended to be connected to a UL Listed/CSA Certified computer which supplies
power directly to the reader or else be supplied by a UL Listed/CSA Certified Power Unit marked
“Class 2” or LPS power source rated 4 - 30 V, minimum 420 mA, which supplies power directly to
the reader via the power connector of the cable.
WEEE COMPLIANCE
For information about the disposal of Waste Electrical and Electronic
Equipment (WEEE), please refer to the website at
www.scanning.datalogic.com.
PATENTS
This product is covered by one or more of the following patents:
Design Pat. AU 310201; AU 310202; CN 693980; HK 0602013.5M001; HK 0602013.5M002; JP
1305693; KR 30-0460940.
US Pat. 5,992,740; 6,305,606 B1; 6,808,114 B1; 6,997,385 B2; 5,103,080; 5,262,627;
5,367,151; 5,449,893; 5,545,889; 5,917,173; 5,923,025; 5,945,659; 6,098,877; 6,220,514 B1;
6,607,132 B1; 6,817,529 B2; 6,834,805 B2.
European Pat. 789,315 B1; 895,175 B1; 1,128,315 B1.
Additional patents pending.
Notch
Align 3
4
5
6
7
Tab
Arrow
1
2
DEFAULT VALUES
USB-KBD DEFAULT SETTINGS
USA keyboard, FIFO enabled, inter-character and inter-code delays disabled,
USB keyboard speed normal.
DATA FORMAT: code identifier disabled, no field adjustment, code length not
transmitted, no header, terminator = ENTER, character replacement disabled.
RS-232 Standard DEFAULT SETTINGS
9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking, delay disabled, rx
timeout 5 sec., ack/nack disabled, FIFO enabled, inter-character delay disabled,
serial trigger lock disabled.
DATA FORMAT: code identifier disabled, no field adjustment, code length not
transmitted, no header, terminator = CR-LF, character replacement disabled.
WEDGE DEFAULT SETTINGS
USA keyboard, caps lock off, caps lock auto-recognition enabled, num lock
unchanged, inter-character and inter-code delays disabled, control character
emulation = ctrl+shift+key.
DATA FORMAT: code identifier disabled, no field adjustment, code length not
transmitted, no header, terminator = ENTER, character replacement disable.
PEN DEFAULT SETTINGS
interpret operating mode, conversion to code 39 disabled, output level normal,
idle level normal, minimum output pulse 600 µs, overflow medium, inter-block
delay disabled.
CODE SELECTION
Enabled codes
EAN 8/EAN 13 / UPC A/UPC E without ADD ON
check digit transmitted, no conversions
Interleaved 2/5
check digit control and transmission, variable length code; 4-99 characters
Standard Code 39
no check digit control, variable length code; 1-99 characters
Code 128
variable length code; 1-99 characters
Disabled codes
EAN 128, ISBT128, Code 93, Codabar, pharmaceutical codes, MSI,
Code 11, Code 16K, Code 49, GS1 DataBar™ Codes
TECHNICAL FEATURES
PowerScan® D8330/ D8330 AR
Electrical Features PowerScan® D8330 PowerScan®
D8330 AR
Power Supply 4 to 30 VDC
Max. Consumption: 0.076 mm (3 mils) 0.25 mm (10 mils)
@ 4V
@5V
@30V
Sleep mode
420 mA
310 mA
62 mA
4 mA
500 mA
370 mA
70 mA
4 mA
Scan Rat 35 ± 5 scans/sec
Reading Indicators Good Read LED (green)
Good Read Spot (green), Beeper
Optical Features
Reading Field
(Typical performance at 20ºC /
68ºF on high quality barcodes)
110 cm (43.3 in)
@ 55 mils
1090 cm (429.13 in)
@ 100 mils reflective
Max. Resolution 0.076 mm (3 mils) 0.178 (7,5 mils)
PCS (Datalogic Test Chart) 15% 25%
Laser Features
Power (max) 0.9 mW 1.3 mW
Scan Angle 42° 13.5° ± 0.7
Laser Safety Class Class 2 EN 60825-1/CDRH
Environmental Features
Working Temperature -30 °C to + 50 °C / -22° to +122 °F
Storage Temperature -30 °C to + 70 °C / -22° to +158 °F
Humidity 90% non condensing
Drop Resistance IEC 68-2-32 Test ED 2 m
Protection Class IP65
Mechanical Features
Weight (without cable) about 295 g (10.4 oz)
Cable Length 2 m (6 ft 6 in)
RESTORE DEFAULT
RESTORE DEFAULT
Ì$+$*oÎ
To change the defaults refer to the PowerScan® D8330/M8330 Reference
Manual, or to the Datalogic Aladdin Configuration program, both downloadable
from the website.
INTERFACE SELECTION
Select one of the interface codes according to your application.
USB INTERFACE SELECTION
USB-KBD
Ì$+UA03$-:Î
USB-KBD-ALT-MODE
Ì$+UA04$-@Î
USB-COM*
Ì$+UA02$-4Î
USB-IBM-Hand Held
Ì$+UA01$-.Î
USB-IBM Table top
Ì$+UA00$-(Î
USB KBD-APPLE
Ì$+UA05$-FÎ
* When configuring USB-COM, the relevant files and drivers must be installed
from the USB Device Installation software, which can be downloaded from the
web site http://www.scanning.datalogic.com.
PEN EMULATION INTERFACE SELECTION
PEN
Ì$+CP6$
-
RS-232 INTERFACE SELECTION
RS-232 Standard
Ì$+CP0$-$Î
Nixdorf Mode A
Ì$+CM2EC0$->Î
Fujitsu
Ì$+CM1$-ÈÎ
ICL Mode
Ì$+CM0$-ÃÎ
WEDGE INTERFACE SELECTION
Wedge IBM AT or PS/2 PCs
Ì$+CP500$-
PC Notebook
Ì$+CP505$-ÈÎ
PC Notebook - ALT mode
Ì$+CP508$-
IBM AT - ALT mode
Ì$+CP507$-
Interface for IBM XT and IBM Terminals 3151, 347X and 348X can be selected
from the PowerScan D8330/M8300 Reference Manual available online at
http://www.scanning.datalogic.com.
KEYBOARD NATIONALITY
USB-KBD and Wedge users should select one of the following wedge keyboard
nationality codes according to the keyboard.
Belge
Ì$+FJ7$-8Î
Deutsch
Ì$+FJ3$-$Î
English
Ì$+FJ4$-)Î
Español
Ì$+FJ6$-3Î
Français
Ì$+FJ2$-ÊÎ
Italiano
Ì$+FJ1$Î
Svenskt
Ì$+FJ5$-.Î
USA (Default)
Ì$+FJ0$-|Î
The following Keyboard Nationality selections are only valid for IBM AT compatible
PCs:
Japanese
Ì$+FJ8$-=Î
Russian (Latin)
Ì$+FJ9$-BÎ
Russian (Cyrillic)
Ì$+FJA$-jÎ
Hungarian
Ì$+FJB$-oÎ
Slovenian, Croatian, Serbian (Latin)
Ì$+FJC$-tÎ
Romanian
Ì$+FJD$-yÎ
Czech Republic
Ì$+FJE$-~Î
USING POWERSCAN® D8330/D8330 AR READERS
PowerScan® D8330 readers automatically scan barcodes at a distance. Simply
aim and pull the trigger. Code scanning is performed along the scan line emitted
from the reading window. This line must cross the entire code. The best reading
angles are indicated in the figure below.
AIMING SYSTEM
PowerScan® D8330 and PowerScan® D8330 AR provides an aiming system. I
f
enabled, a partial trigger press produces a red spot, which should be aimed ove
r
the code center to get the best reading performance (see figure above, c). B
y
completely pressing the trigger the scan line appears to start code scanning d.
After setting up the reader, you can enable or disable the aiming system by
reading the codes below:
Disable Aiming System (Default)
Ì$+Bj0$-"Î
Enable Aiming System
Ì$+Bj1$-'Î
DATA FORMAT TERMINATORS
For your convenience, some common Terminators are given below. For other
Header/Terminator selections, Data Format and Advanced Data Format
parameters, see the PowerScan® D8330/M8330 Reference Manual.
CR-LF
Ì$+EA120D0A$-ÃÎ
Enter
Ì$+EA1183$-0Î
Tab
Ì$+EA1184$-8Î
None
Ì$+EA10$-dÎ
OPERATING TEST
Read the TEST code below.
Code 128
t e s t


Product specificaties

Merk: Datalogic
Categorie: Barcode lezer  
Model: PowerScan PD830
Kleur van het product: Geel
Gewicht: 295 g
Snoerlengte: 2.4 m
Ingangsspanning: 4 - 30 V
Temperatuur bij opslag: -30 - 50 °C
Stroomverbruik: 420 mA
Veiligheid: CDRH 21 CFR 1040, EN60825-1, EU RoHS
Standaard interfaces: RS-232,USB,Keyboard wedge
Afmetingen (B x D x H): 207 x 69 x 114 mm
Bedrijfstemperatuur (T-T): -30 - 50 °C
Bereik kantelhoek: 5 - 55 °
Lichtbron: 630 - 680
Scansnelheid: 35 sec/pagina
Werkafstand: 21 mm
Decoding standaarden: 1D/GS1 DataBar\n16K\n49\nGS1 DataBar Expanded/Stacked/Stacked Omnidirectional

Heb je hulp nodig?

Als je hulp nodig hebt met Datalogic PowerScan PD830 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Barcode lezer   Datalogic

Handleiding Barcode lezer  

Nieuwste handleidingen voor Barcode lezer