Datalogic DS8100A Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Datalogic DS8100A (141 pagina's) in de categorie Barcode lezer  . Deze handleiding was nuttig voor 67 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/141
DS8100A
Reference Manual
Datalogic Automation Srl
Via Lavino, 265
40050 - Monte S. Pietro
Bologna - Italy
DS8100A Reference Manual
Ed.: 10/2012
© 2005 2012 Datalogic Automation S.r.l. ALL RIGHTS RESERVED. Protected to the fullest
extent under U.S. and international laws. Copying, or altering of this document is prohibited without
express written consent from Datalogic Automation S.r.l.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries,
including the U.S.A. and the E.U.
Genius, PackTrack, ACR, ASTRA, CD SQUARE and ID-NET are trademarks of Datalogic Automation
S.r.l. All other brand and product names mentioned herein are for identification purposes only and may
be trademarks or registered trademarks of their respective owners.
Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for
incidental or consequential damages resulting from the use of this material.
02/10/12
iii
CONTENTS
REFERENCES ............................................................................................................ vi
Reference Documentation ........................................................................................... vi
Services and Support .................................................................................................. vi
Patents......................................................................................................................... vi
COMPLIANCE............................................................................................................ vii
Electrical Safety ...........................................................................................................vii
Laser Safety.................................................................................................................vii
Power Supply..............................................................................................................viii
CE Compliance...........................................................................................................viii
FCC Compliance ......................................................................................................... ix
GENERAL VIEW .......................................................................................................... x
GUIDE TO INSTALLATION ....................................................................................... xii
Point-to-Point Installation.............................................................................................xii
Master/Slave Lonworks Installation ............................................................................xiii
1 1 INTRODUCTION ..........................................................................................................
1.1 Product Description ...................................................................................................... 1
1.2 Applications .................................................................................................................. 1
1.3 Model Description.........................................................................................................3
1.4 Oscillating Mirror Models ..............................................................................................3
1.5 Indicators ...................................................................................................................... 4
1.6 Keypad and Display......................................................................................................5
1.6.1 Internal Net ...................................................................................................................5
1.6.2 Test Mode.....................................................................................................................5
1.6.3 PackTrack (Auto) ..........................................................................................................6
1.7 Auto PackTrack™ Calibration for Reading Station Using Scanner Menu .................... 7
1.7.1 Auto PackTrack Conditions and Limits .........................................................................7
1.7.2 Auto PackTrack Parameter Descriptions......................................................................8
1.7.3 Auto PackTrack Setup ..................................................................................................9
1.8 Accessories ................................................................................................................12
2 INSTALLATION ......................................................................................................... 14
2.1 Package Contents ......................................................................................................14
2.2 Mechanical Mounting..................................................................................................15
2.2.1 Mounting the Scanner.................................................................................................15
2.2.2 Mounting the Scanner with Accessories.....................................................................16
2.3 Positioning the Scanner..............................................................................................18
3 CBX ELECTRICAL CONNECTIONS......................................................................... 19
3.1 Power Supply..............................................................................................................21
3.2 Main Serial Interface...................................................................................................21
3.2.1 RS232 Interface..........................................................................................................22
3.2.2 RS485 Full-Duplex Interface.......................................................................................23
3.2.3 RS485 Half-Duplex Interface ......................................................................................24
3.3 Auxiliary RS232 Interface ...........................................................................................26
3.4 Inputs .......................................................................................................................... 27
3.4.1 Code Verifier...............................................................................................................31
3.5 Outputs .......................................................................................................................31
v
10.3.1 ASR Network Configuration...................................................................................... 108
10.3.2 Scanner Replacement Procedure............................................................................. 108
11 109 TROUBLESHOOTING .............................................................................................
12 112 TECHNICAL FEATURES.........................................................................................
A ALTERNATIVE LAYOUTS ......................................................................................114
Point-to-Point ............................................................................................................114
ID-NET™ Gateway ...................................................................................................116
Pass Through ...........................................................................................................117
RS232 Master/Slave.................................................................................................118
Multiplexer ................................................................................................................120
GLOSSARY.............................................................................................................. 121
INDEX.......................................................................................................................124
xi
Figure C – Display and Keypad Panel
Programming Keypad
Power On LED (Green)
Phase On LED
(
Yellow
)
Encoder LED (Yellow)
1
2
3
4
TX Data LED (Green)
Network LED (Red)
LCD Display
5
6
7
Figure D – Connector Panel for Standard Models
Lonworks 17-pin male connector
Lonworks 17-pin female connector
1
2
Serial interface and I/O 26-pin connector
3
Figure E – Connector Panel for Ethernet Models
Figure F – Connector Panel for (older) Ethernet Models
Lonworks 17-pin male connector
Lonworks 17-pin female connector Harting RJ industrial connector
1
2 4
Serial interface and I/O 26-pin connector
3
1
2
3
1
2
4
3
7
1
2 3 4 5 6
1
2
4
3
Lonworks 17-pin male connector
Lonworks 17-pin female connector Ethernet M12 4-pin female connector
1
2 4
Serial interface and I/O 26-pin connector
3
xiii
MASTER/SLAVE LONWORKS INSTALLATION
The following can be used as a checklist to verify all the steps necessary to complete
installation of the DS8100A scanner in a Master/Slave Lonworks network.
1) Read all information in the section “Safety Regulations” at the beginning of this manual.
2) Correctly mount the scanner according to the information in par. 2.2 and position it at the
correct reading distance as shown in par. 2.3 and par. 9.4.
3) Make electrical connections to your DS8100A scanner by:
a) Connecting the DS8100A Master scanner to the CBX100 by means of one of the
CAB-F0x cables provided as accessory (see par. 1.8).
b) Correctly terminating the DS8100A Master reader according to the information given
in par. 5.1 and par. 7.1.
c) Completing the system wiring adding as many slave scanners as required by your
system layout (refer to par. 7.1).
d) Correctly providing bus return to the last DS8100A Slave reader of the network
according to the information given in par. 5.1 and par. 7.1.
4) Install and run the Genius™ configuration program from the CD-ROM provided.
Configure the Local Lonworks Network using one of the procedures given below :
Configure the entire network through the Master as described in par. 8.2.2;
Configure the Master as described in par. 8.2.2 and locally define each slave scanner
address as described in par. 8.2.3.
Define each scanner, master and slaves (with their addresses), by using the scanner
keypad according to the information given in par. 1.6.1.
5) Configure the Master scanner through the Genius™ program. See chapter 8 and the
Help On-Line for details. The main steps are:
Select the codes to be read
Set-up the communication parameters
When PackTrack™ is required, perform PackTrack™ calibration, see par. 9.2.1.
Define data formatting parameters
6) Configure each Slave scanner through the Master scanner using Genius™. See chapter
8 and the Help On-Line for details. The main steps are:
Select the codes to be read
When PackTrack™ is required, perform PackTrack™ calibration, see par. 9.2.1.
NOTE
Fine tuning of the scanner position for barcode reading can be
accomplished by performing a test through the SPY configuration tool in
Genius™.
INTRODUCTION
1
1
1 INTRODUCTION
1.1 PRODUCT DESCRIPTION
The DS8100A scanner is a barcode reader complete with decoder designed to provide an
innovative and high performance solution in omnidirectional reading applications by
combining the following advanced technologies with Datalogic solid experience in the
material handling sector.
Some of the main features of DS8100A are listed below:
scanning speed 1000 scans/sec.
reads all popular codes.
supply voltage from 20 to 30 Vdc.
test mode to verify the reading features and exact positioning of the scanner without the
need for external tools.
programmable in several different operating modes to suit the most various barcode
reading system requirements.
light source: solid state laser diodes; the light emitted has a wave length between
630~680 nm. For laser safety precautions refer to the “Compliance section at the
beginning of this manual.
1.2 APPLICATIONS
The DS8100A barcode reader is specifically designed for industrial applications and for all
cases requiring high reading performance such as:
code reconstruction
reading of codes covered by plastic film
reading of codes with a wide depth of field
reading of high resolution codes positioned at long distances from the reader
code reading on fast moving objects.
DS8100A is designed for both single-reader layouts and multi-reader layouts. For typical
layouts see chapter 7 and appendix A.
INTRODUCTION
3
1
Feature Benefit
Energy Saving A software parameter group which allows
management of the energy saving feature. In
particular, it allows turning on/off the motor and
laser of all network scanners according to the
selected digital input, encoder, or communication
channel.
The time required to restart the system is less
than 1 minute independently from the number of
scanners connected.
It is suggested to use this parameter for example
when the conveyor is stopped for a lengthy
period.
1.3 MODEL DESCRIPTION
The DS8100A scanner is available in versions that differ depending on the interface
connection, the optical resolution and on the optic version:
DS8100A - X X X
X
O
p
tic Version:
0 = Linear
O
p
tical Resolution:
0 = Low resolution
1 = Medium resolution
Communication Type:
0 = Standard version
1 = Ethernet version 2 = High resolution
3 = Very High resolution
5 = Oscillating mirror
Laser Number:
2 = Double laser
3 = Tri
p
le laser
1.4 OSCILLATING MIRROR MODELS
Oscillating mirror models are used when coverage of a large reading area is required, mainly
in picket fence applications.
The oscillating mirror is placed in front of the reading aperture of the DS8100A scanner to
deflect the laser beam. As the mirror moves, this sweeping function of the laser beam allows
the coverage of a larger area to locate the barcodes. The code can also be reconstructed as
the beam sweeps over it.


Product specificaties

Merk: Datalogic
Categorie: Barcode lezer  
Model: DS8100A
Kleur van het product: Grey, White
Gewicht: 5000 g
Materiaal behuizing: Aluminium
Stroomvoorziening: 30 VCD
LED-indicatoren: Stroom
Beeldscherm: LCD
Gewicht basisstation: 6400 g
Aantal toetsen: 3 toetsen
Type beeldsensor: Laser
Temperatuur bij opslag: -20 - 70 °C
Standaard interfaces: RS-232, RS-485
Afmetingen (B x D x H): 215.5 x 170.5 x 126.5 mm
Bedrijfstemperatuur (T-T): 0 - 50 °C
Lichtbron: 630 - 680
Lees-snelheid (max): 1000 lezingen/s

Heb je hulp nodig?