Two- door Sub Access Controller
User’ s Manual
V1.0.3
I
Cybersecurity Recommendations
The necessary measures to ensure the basic cyber security of the platform:
1. Use Strong Passwords
Please refer to the following suggestions to set passwords:
The length should not be less than 8 characters.
Include at least two types of characters; character types include upper and lower case letters, numbers
and symbols.
Do not contain the account name or the account name in reverse order.
Do not use continuous characters, such as 123, abc, etc.
Do not use overlapped characters, such as 111, aaa, etc.
2. Customize the Answer to the Security Question
The security question setting should ensure the difference of answers, choose different questions
and customize different answers (all questions are prohibited from being set to the same answer) to
reduce the risk of security question being guessed or cracked.
Recommendation measures to enhance platform cyber security:
1. Enable Account Binding IP/MAC
It is recommended to enable the account binding IP/MAC mechanism, and configure the IP/MAC
of the terminal where the commonly used client is located as an allowlist to further improve access
security.
2. Change Password Regularly
We suggest that you change passwords regularly to reduce the risk of being guessed or cracked.
3. Turn On Account Lock Mechanism
The account lock function is enabled by default at the factory, and it is recommended to keep it
on to protect the security of your account. After the attacker has failed multiple password attempts,
the corresponding account and source IP will be locked.
4. Reasonable Allocation of Accounts and Permissions
According to business and management needs, reasonably add new users, and reasonably
allocate a minimum set of permissions for them.
5. Close Non- essential Services and Restrict the Open Form of Essential Services
If not needed, it is recommended to turn off NetBIOS (port 137, 138, 139), SMB (port 445), remote
desktop (port 3389) and other services under Windows, and Telnet (port 23) and SSH (port 22) under
Linux. At the same time, close the database port to the outside or only open to a specific IP address,
s uch as MySQL (port 3306), to reduce the risks faced by the platform.
6. Patch the Operating System/Third Party Components
II
It is recommended to regularly detect security vulnerabilities in the operating system and third-
party components, and apply official patches in time.
7. Security Audit
Check online users: It is recommended to check online users irregularly to identify whether there are
illegal users logging in.
View the platform log: By viewing the log, you can get the IP information of the attempt to log in to
the platform and the key operation information of the logged- in user.
8. The Establishment of a Secure Network Environment
In order to better protect the security of the platform and reduce cyber security risks, it is
recommended that:
Follow the principle of minimization, restrict the ports that the platform maps externally by firewalls
or routers, and only map ports that are necessary for services.
Based on actual network requirements, separate networks: if there is no communication requirement
between the two subnets, it is recommended to use VLAN, gatekeeper, etc. to divide the network to
achieve the effect of network isolation.
.
IV
There still might be deviation in technical data, functions and operations description, or errors in
print. If there is any doubt or dispute, please refer to our final explanation.
Upgrade the reader software or try other mainstream reader software if the Guide (in PDF format)
cannot be opened.
All trademarks, registered trademarks and the company names in the Manual are the properties
of their respective owners.
Please visit our website, contact the supplier or customer service if there is any problem occurred
when using the device.
If there is any uncertainty or controversy, please refer to our final explanation.
V
Important Safeguards and Warnings
The following description is the correct application method of the device. Please read the manual
carefully before use, in order to prevent danger and property loss. Strictly conform to the manual
during application and keep it properly after reading.
Operating Requirement
Please don t place and install the device in an area exposed to direct sunlight or near heat
generating device.
Please don t install the device in a humid, dusty or fuliginous area.
Please keep its horizontal installation, or install it at stable places, and prevent it from falling.
Please don’t drip or splash liquids onto the device; don’t put on the device anything filled with
liquids, in order to prevent liquids from flowing into the device.
Please install the device at well-ventilated places; don’t block its ventilation opening.
Use the device only within rated input and output range.
Please don’t dismantle the device arbitrarily.
Please transport, use and store the device within allowed humidity and temperature range.
Power Requirement
Please make sure to use batteries according to requirements; otherwise, it may result in fire,
explosion or burning risks of batteries!
To replace batteries, only the same type of batteries can be used!
The product shall use electric cables (power cables) recommended by this area, which shall be
used within its rated specification!
Please use standard power adapter matched with the device. Otherwise, the user shall undertake
resulting personnel injury or device damage.
Please use power supply that meets SELV (safety extra low voltage) requirements, and supply
power with rated voltage that conforms to Limited Power Source in IEC60950-1. For specific
power supply requirements, please refer to device labels.
Products with category I structure shall be connected to grid power output socket, which is
equipped with protective grounding.
Appliance coupler is a disconnecting device. During normal use, please keep an angle that
facilitates operation.
1
1 Overview
As a sub main controller main of access controller, two-door sub access controller is matched with
main access controller and is widely used in banks, safe places, and more.
Its rich functions are as follows:
Adopt sliding rail type and lock type installation, convenient installation and maintenance.
Integrate alarm and fire alarm.
Support 4 sets of card readers.
Support signal and 9 groups of input (exit button *2, door sensor *2 intrusion alarm *5).
Support 5 groups of control output (electric lock *2 and alarm output *3).
With RS485 port, it may extend to connect lift control module, alarm or household control module.
Support controller. CAN bus and connect main access
FLASH storage capacity is 16M (which may extend to 32M), max supports 20,000 card holders and
30,000 offline records.
Support illegal intrusion alarm, overtime alarm, duress card alarm and duress code setup. exit
Also support blocklist and allow and patrol card setup. list
Data storage during outage, built-in RTC (support DST), online upgrading.
If this product needs to connect external power supply, please use 12V 0.5 A adapter and ensure that
working temperature shall not exceed -5 . +55
3
3 Installation Guide
System Structure
External Dimension
The unit is mm.
4
Device Installation
There are two installation modes.
Mode 1: fix the whole device onto the wall with screws.
Mode 2: install U-shaped guide rail, and hang the whole device onto the wall (U-shaped guide rail
is a self- ). bought fitting
Mode 1
Installation diagram is shown below.
6
Wiring Description
Device wiring diagram is shown below.
Interfaces are described in the table below.
Table 3-1
No. No. Interface Description Interface Description
1 b 9 CAN us Not available at present
2 External extension module reader of door 1 10 Entry
3 Door sensor and exit button reader of door 1 11 Exit
7
No. No. Interface Description Interface Description
4 External alarm input 12 Entry reader of door 2
5 External alarm output 13 Exit reader of door 2
6 Lock control output 14 Reboot
7 Internal alarm output 15 DC 12V power interface
8 Address code/transmission rate
Indicator lights are described in the table below.
Table 3-2
No. Description
16 Lock status indicator
17
18 Alarm status indicator
19
20 indicator Power
1.1.1 Wiring Description of CAN Bus
Wiring terminals of CAN bus are described in the table below.
Table 3-3
Interface Wiring Terminal Description
CAN bus
CANL CAN bus input
CANH
CANL CAN bus output
CANH
3.5.2 Wiring Description of Exit Button/Door Sensor
Corresponding wiring terminals of exit button and door sensor are shown in Figure 3-8. Please refer to
Table 3-4 for descriptions of wiring terminals.
Table 3-4
Interface Wiring Terminal Description
Exit
button+ door
sensor GND Shared by exit button of door 1 and door
sensor input of door 1
10
Interface Wiring Terminal Description
Lock control output
NC1
Lock control of door 1 COM1
NO1
NC2
Lock control of door 2 COM2
NO2
3.5.6 Wiring Description of Internal Alarm Output
Corresponding wiring terminals of internal alarm control output are shown below.
Table 3-8
Interface Wiring Terminal Description
Internal alarm control
output
NC1 Intrusion, overtime and vandal alarm - proof
output of door 1. Output time lasts for 15s.
COM1
NO1
NC2 Intrusion, overtime and vandal alarm - proof
output of door 2. Output time lasts for 15s.
COM2
NO42
3.5.7 Wiring Description of Reader
1 door only supports to connect one type of reader: RS-485 or Wiegand.
Please refer to Table 3-9 for descriptions of wiring terminals corresponding to readers. Take Door 1 for
example, and other readers are the same as door 1. Please refer to the table below for descriptions of
video cable specification and length.
Table 3-9
Interface Wiring Terminal Cable Color Description
Entry Reader of
Door 1
485+ Purple 485 reader
485- Yellow
LED Brown
Wiegand reader
D0 Green
D1 White
CASE Blue
GND Black Reader power supply
12V Red
Table 3- 10
Reader Type Connection Mode Length
485 Reader CAT5e network cable, 485 connection 100m
Wiegand Reader CAT5e network cable, Wiegand connection 30m


Product specificaties

Merk: Dahua Technology
Categorie: Toegangscontrolesysteem
Model: ASC2102B-T
Gewicht: 500 g
Breedte: 116 mm
Diepte: 210 mm
Hoogte: 51.2 mm
Kastontwerp: Bloot
Certificering: CE, FCC
Interface: RS-485
Intern geheugen: 0.016 GB
Aantal gebruikers: 20000 gebruiker(s)
Stroomverbruik: 500 mA
Maximum aantal deuren: 9 deur(en)
DC voltage bereik: 12 V
Bedrijfstemperatuur (T-T): -30 - 60 °C
Relatieve vochtigheid in bedrijf (V-V): 0 - 95 procent
RS-485 ports: 1
Evenementcapaciteit: 30000
Aantal kaarthouders: 20000