Citizen CAL B742 Handleiding

Citizen Horloge CAL B742

Lees hieronder de 📖 handleiding in het Nederlandse voor Citizen CAL B742 (1 pagina's) in de categorie Horloge. Deze handleiding was nuttig voor 63 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/1
112
Crown
MODELS – BJ * ECO-DrIvE aQUaLanD2**
Mvmt. Cal. No. B74* Level of
Stored Energy
Lower
Right
Button (A)
Upper
Right
Button (B)
‘Real Time’ Second Hand
Function
Hand
24 Hour
Hand
Mode Hand
Date
FEATURES
Light Powered
Depth Sensor
Depth Indicator Hand
Elapsed-Time Bezel
Water Sensor
50 Minute Chronograph
Water-Resistant to 200 Meters
Reserve Power Indicator
Rechargeable Battery
BENEFITS
Free Energy Source
Accurate Depth Indication
Instant Depth Reading
Assists in Measuring ‘Down Time’
Automatically Switches to Dive Mode
Precise Measurement of Elapsed-Time
Good for Scuba Diving
Safe Dives
No Battery Changes
IMPORTANT NOTE: Before use, be sure the watch is
fully charged. The charge level of the energy cell can be
checked by placing the watch in time mode. The function
hand (sweep second hand) will move to one of three
positions indicating the level of stored energy. Level
2 indicates a maximum charge*. Level 1 indicates the
charge level is in normal operating range. NG indicates
the charge level is not sufficient for diving and is getting
low for normal operation. For recharge times and rates,
refer to your instruction manual or visit our website at
www.citizenwatch.com. Do not use a halogen light, or
place the watch on the dashboard of a car for charging as
temperatures in excess of 140 degrees Fahrenheit can be
reached which may damage vital components of the watch.
If either a low charge/no charge state is reached, or the
function hand continues to indicate ‘over-zone’, or
another malfunction is experienced, then an ALL RESET
AND 0-POSITIONING PROCEDURES will be required.
ALL RESET AND 0-POSITIONING PROCEDURES
Unscrew the crown to release it from the case and pull
it out two ‘clicks’. Simultaneously push the upper right
(B) and the lower right (A) buttons at the same time and
hold down for 2-3 seconds, then release. This ‘resets’ the
movement.
Press the upper right button (B) to set the function
and mode hands to the 0 or 12:00 position.
Set the time if necessary.
Return the crown to its position next to the case and
screw it in to secure it.
Note: After the ALL RESET, the function hand will
indicate ‘NG’ charge for approximately one hour, then will
return to the correct charge indication.
TO CHANGE MODES
To switch to the chronograph mode while in normal
time display mode, (mode hand on DV), press and hold
down the lower right button (A) for 3 seconds. Mode and
function hands will move to 0-position.
To switch back to normal time display mode from
chronograph mode, press and hold the lower right button
(A) for 3 seconds.
Watch switches to dive standby mode automatically when
sensor is wet.
To switch back to time after dive, press and hold the
upper right button (B) for 3 seconds.
To call up maximum depth memory of the last dive,
while in the time or dive mode, press the upper right
button (B). The depth indicator hand (mode hand) will
move to show the deepest point of the last dive. Press and
release the upper right button (B) again to return the depth
indicator hand (mode hand) back to its previous position.
TO SET THE TIME
Unscrew the crown by turning it in a counter clockwise
direction to release it.
Pull the crown out two ‘clicks’ to set the Hour and
Minute hands. Turn the crown to move the hands forward
to the correct time while observing the 24 Hour hands so
as to properly set the time for a.m. or p.m.
Push the crown in to finalize setting.
TO SET THE DATE
After the correct time has been set (24 Hour hand
indicating whether time is a.m. or p.m.) and the crown is
pulled out one ‘click’ (intermediate position), then rotate
the crown in the counterclockwise direction to set the date.
Once time and/or date is set, then push the crown in
against the case and while continuing to apply pressure,
turn the crown clockwise until it is screwed tightly
against the case.
TO USE THE CHRONOGRAPH
Hold the lower right button (A) down for 3 seconds
while in normal time display mode to switch to
chrono graph mode. Function hand now becomes
chrono graph sweep second hand and mode indicator
becomes minute register hand. Small second hand
always shows actual running seconds.
Press and release the upper right button (B) to start or
stop chronograph.
When stopped, press the lower right button (A) to
reset hands to 0-position. If either of the two hands does
not return to the 0-position, please refer to the ALL
RESET PROCEDURE outlined previously.
To return to normal time display mode from chrono -
graph mode, press and hold the lower right button (A).
Chronograph does not operate simultaneously with time
or dive mode. If mode is switched from chronograph,
chronograph data is deleted.
TO USE THE DEPTH METER
Before the watch goes into dive standby mode and before
diving, make sure ‘screw lock’ crown is tightened securely
against the case. Watch is now ready for diving.
Watch will automatically switch to dive standby mode
from either normal time or chronograph mode whenever
water sensor gets wet. Mode hand moves to ‘DV’ and
depth indicator hand will move to ‘0’ feet. (If this does
not happen, please refer to the ALL RESET PROCEDURE
outlined previously).
To read the maximum depth memo for the last dive
(after all moisture has been removed from exterior of
watch) press the upper right button (B) while in time or
dive mode. Depth indicator hand will point to the
maximum depth of your last dive.
Press the upper right button (B) again to return to the
previous mode.
Depth meter and chronograph cannot be used
simultaneously. The elapsed time indicator (ETI) bezel
ring should be used to keep track of elapsed dive time
(see your instruction manual for detailed information).
Maximum depth measurement is 125 feet. If diver exceeds
that depth, depth indicator hand rests on ‘over-zone’ mark
until returning to 125 feet or less.
Always use the ‘buddy system’ when diving. This
watch is not a substitute for a dive partner.
It is recommended that there be no diving unless the
power level indicator is at Level 1 or 2.
*Level 2 indicates maximum charge level and will remain
there for 3-8 hours depending on the type of light used
for charging and functions of the watch being utilized.
For charge rates and additional in depth instructions,
please refer to the full instruction manual or our website
at www.citizenwatch.com.


Product specificaties

Merk: Citizen
Categorie: Horloge
Model: CAL B742

Heb je hulp nodig?

Als je hulp nodig hebt met Citizen CAL B742 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Horloge Citizen

Handleiding Horloge

Nieuwste handleidingen voor Horloge