(continued on next page)
Supported signals for COMPUTER IN
Resolution (H x V) Signal mode H. frequency
(kHz)
V. frequency
(Hz)
Rating
720 x 400 TEXT 37.9 85 VESA
640 x 480 VGA (60Hz) 31.5 59.9 VESA
VGA (72Hz) 37.9 72.8 VESA
VGA (75Hz) 37.5 75 VESA
VGA (85Hz) 43.3 85 VESA
800 x 600 SVGA (56Hz) 35.2 56.3 VESA
SVGA (60Hz) 37.9 60.3 VESA
SVGA (72Hz) 48.1 72.2 VESA
SVGA (75Hz) 46.9 75 VESA
SVGA (85Hz) 53.7 85.1 VESA
832 x 624 Mac 16” mode 49.7 74.5
1024 x 768 XGA (60Hz) 48.4 60 VESA
XGA (70Hz) 56.5 70.1 VESA
XGA (75Hz) 60 75 VESA
XGA (85Hz) 68.7 85 VESA
1152 x 864 1152 x 864 (75Hz) 67.5 75 VESA
1280 x 768 W-XGA (60Hz) 47.7 60 VESA
1280 x 800 1280 x 800 (60Hz) 49.7 60 VESA
1280 x 1024 SXGA (60Hz) 64 60 VESA
SXGA (75Hz) 80 75 VESA
SXGA (85Hz) 91.1 85 VESA
*1) 1366 x 768 WXGA (60Hz) 47.7 59.8 VESA
1440 x 900 WXGA+ (60Hz) 55.9 59.9 VESA
1600 x 900 WXGA++ (60Hz) 60 60 VESA
1680 x 1050 WSXGA+ (60Hz) 65.3 60 VESA
1600 x 1200 UXGA (60Hz) 75 60 VESA
1920 x 1080 Full HD (60Hz) 67.5 60 VESA
*2) 1920 x 1200 W-UXGA (60Hz)
Reduced Blanking 74 60 VESA
*1) Only for [WXGA Model] *2) Only for [WUXGA Model]

LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016) 2
Supported signals
Supported signals for HDMI / HDBaseT
Resolution (H x V) Signal mode H. frequency
(kHz)
V. frequency
(Hz)
Rating
720 x 400 TEXT 37.9 85 VESA
640 x 480 VGA (60Hz) 31.5 59.9 VESA
VGA (72Hz) 37.9 72.8 VESA
VGA (75Hz) 37.5 75 VESA
VGA (85Hz) 43.3 85 VESA
800 x 600 SVGA (56Hz) 35.2 56.3 VESA
SVGA (60Hz) 37.9 60.3 VESA
SVGA (72Hz) 48.1 72.2 VESA
SVGA (75Hz) 46.9 75 VESA
SVGA (85Hz) 53.7 85.1 VESA
832 x 624 Mac 16” mode 49.7 74.5
1024 x 768 XGA (60Hz) 48.4 60 VESA
XGA (70Hz) 56.5 70.1 VESA
XGA (75Hz) 60 75 VESA
XGA (85Hz) 68.7 85 VESA
1152 x 864 1152 x 864 (75Hz) 67.5 75 VESA
1280 x 768 W-XGA (60Hz) 47.7 60 VESA
1280 x 800 1280 x 800 (60Hz) 49.7 60 VESA
1280 x 1024 SXGA (60Hz) 64 60 VESA
SXGA (75Hz) 80 75 VESA
SXGA (85Hz) 91.1 85 VESA
1366 x 768 WXGA (60Hz) 47.7 59.8 VESA
1440 x 900 WXGA+ (60Hz) 55.9 59.9 VESA
1600 x 900 WXGA++ (60Hz) 60 60 VESA
1400 x 1050 SXGA+ (60Hz) 65.2 60 VESA
1680 x 1050 WSXGA+ (60Hz) 65.3 60 VESA
1600 x 1200 UXGA (60Hz) 75 60 VESA
*1) 1920 x 1200 W-UXGA (60Hz)
Reduced Blanking
74 60 VESA
*1) Only for [WUXGA Model]
(continued on next page)

LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016) 3
Resolution (H x V) Signal mode H. frequency
(kHz)
V. frequency
(Hz)
Rating
720(1440) x 480i 480i 15.7 60 CEA
720 x 480p 480p 31.5 60 CEA
1280 x 720p 720p (60Hz) 45 60 CEA
1920 x 1080i 1080i (60Hz) 33.8 60 CEA
1920 x 1080p 1080p (60Hz) 67.5 60 CEA
Supported signals
NOTE • Check jack type, signal level, timing and resolution before
connecting this projector to a PC.
• Some PCs may have multiple display screen modes. Use of some of these
modes is not possible with this projector.
• Depending on the input signal, full-size display may not be possible in some
cases. Refer to the number of display pixels above.
• LW502 and LWU502 are not recommended for use with 50Hz signal inputs.
• The signal is converted to the projector’s panel resolution before being
displayed. The best display performance is achieved if the resolutions of the
input signal and projector panel are identical.
• Automatic adjustment may not function correctly with some input signals.
• The image may not be displayed correctly when the input sync signal is a
composite sync or a sync on G.
• The illustrations in this manual are for illustrative purposes. They may differ
slightly from your projector.

LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016) 4
ACOMPUTER IN, BMONITOR OUT
D-sub 15pin mini shrink jack
<Computer signal>
• Video signal: RGB separate, Analog, 0.7Vp-p, 75Ω terminated (positive)
• H/V. sync. signal: TTL level (positive/negative)
• Composite sync. signal: TTL level
<Component video signal>
• Video signal: Y with composite sync, Analog, 1.0±0.1Vp-p, 75Ω terminated
Cb/Pb, Analog, 0.7±0.1Vp-p, 75Ω terminated
Cr/Pr, Analog, 0.7±0.1Vp-p 75Ω terminated
• System: 480i@60, 480p@60, 720p@60, 1080i@60, 1080p@60
Pin Signal Pin Signal
1 9 (No connection)Video Red, Cr/Pr
2Video Green, Y 10 Ground
3 (No connection)Video Blue, Cb/Pb 11
4 (No connection) 12 A: SDA (DDC data) B: (No connection)
5 Ground 13 H. sync / Composite sync.
6 14 V. sync.Ground Red, Ground Cr/Pr
7Ground Green, Ground Y 15 A: SCL (DDC clock) B: (No connection)
8Ground Blue, Ground Cb/Pb
Connection to the ports
① ⑤④③②
⑥ ⑩⑨⑧⑦
⑪ ⑮⑭⑬⑫
Connection to the ports
B
A
NOTICE ►Use the cables with straight plugs, not L-shaped ones, as the
input ports of the projector are recessed.
►Only the signal that is input from the can be output from theCOMPUTER IN
MONITOR OUT port.

LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016) 5
Connection to the ports (continued)
DHDMI 1, EHDMI 2, FHDMI OUT
• Type :Digital audio/video connector
• Audio signal: Linear PCM (Sampling rate; 32/44.1/48 kHz)
Pin Signal Pin Signal Pin Signal
1T.M.D.S. Data2 +
N.C. 8T.M.D.S. Data0 Shield 15 SCL
CD_PULLUP
2T.M.D.S. Data2 Shield
CD_SENSE 9 T.M.D.S. Data0 - 16 SDA
N.C.
3T.M.D.S. Data2 -
N.C. 10 T.M.D.S. Clock +
N.C. 17 DDC/CEC Ground
VBUS_CBUS_GND
4T.M.D.S. Data1 +
N.C. 11 T.M.D.S. Clock Shield
TMDS_GND
18
+5V Power
VBUS
5T.M.D.S. Data1 Shield
TMDS_GND 12 T.M.D.S. Clock -
N.C. 19 Hot Plug Detect
CBUS
6T.M.D.S. Data1 -
N.C. 13 CEC
N.C.
7 T.M.D.S. Data0 + 14 Reserved (N.C. on device)
N.C.
① ⑤
④
③
②⑥⑩
⑨
⑧
⑦⑪⑮
⑭
⑬
⑫
⑲
⑱
⑰
⑯
C
HDBaseT
RJ-45 jack
Pin Signal Pin Signal Pin Signal
1 HDBaseT0+ 4 HDBaseT2+ 7 HDBaseT3+
2 HDBaseT0- 5 HDBaseT2- 8 HDBaseT3-
3 HDBaseT1+ 6 HDBaseT1-
① ⑤
④
③
② ⑥ ⑧
⑦
C
D E
F

LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016) 6
Connection to the ports (continued)
GVIDEO
RCA jack
• Composite video signal, Analog, 1.0±0.1Vp-p, 75Ω terminator
• System: NTSC, PAL, SECAM, PAL-M, PAL-N, NTSC4.43, PAL(60Hz)
G
HAUDIO IN1
Ø3.5 stereo mini jack
•
Analog, 47kΩ input impedance
AUDIO IN2 IL, JR
RCA jack x2
•
Analog, 47kΩ input impedance
AUDIO OUT K
Ø3.5 stereo mini jack
•
Analog, 1kΩ output impedance
K
H
JI
L
CONTROL
D-sub 9pin plug
* About the details of RS-232C communication,
refer to the next section.
Pin Signal Pin Signal Pin Signal
1 (No connection) 4 (No connection) 7 RTS
2 RD 5 Ground 8 CTS
3 TD 6 (No connection) 9 (No connection)
①②
⑥⑦⑧⑨
⑤④③
L

LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016) 7
Connection to the ports (continued)
REMOTE CONTROL OIN, POUT
Ø3.5 stereo mini jack
M
LAN
RJ-45 jack
* About the details of network communication,
refer to the Network Guide.
Pin Signal Pin Signal Pin Signal
1 TX+ 4 - 7 -
2 TX- 5 - 8 -
3 6 RX-RX+
NWIRELESS
Only for USB wireless adapter.
Pin Signal
1 +5V
2 - Data
3 + Data
4 Ground
① ⑤
④
③
② ⑥ ⑧
⑦
①④ ③ ②
M
N
P
O

LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016) 8
①②
⑥⑦⑧⑨
⑤④③
CD (1) (1) −
RD(2) (2) RD
TD (3) (3) TD
DTR (4) (4) −
GND (5) (5) GND
DSR (6) (6) −
RTS (7) (7) RTS
CTS (8) (8) CTS
RI (9) (9) −
RS-232C Communication
RS-232C Communication
When the projector connects to the computer by RS-232C communication, the
projector can be controlled with RS-232C commands from the computer.
For details of RS-232C commands, refer to RS-232C Communication / Network
command table (&17).
Connection
1. Turn off the projector and the computer.
2. Connect the projector's port and the computer's RS-232C port CONTROL
with a RS-232C cable (cross). Use the cable that ful lls the speci cation
shown in gure.
3. Turn the computer on, and after the computer has started up turn the projector
on.
4. Set the COMMUNICATION TYPE to OFF in the COMMUNICATION menu of the
OPTION - SERVICE menu.
1
9876
5432
CONTROL port
of the projector
RS-232C port
of the computer
(cross)
RS-232C Cable
RS-232C CONTROL

LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016) 9
RS-232C Communication (continued)
Communication settings
1. Protocol
19200bps, 8N1
2. Command format ("h" shows hexadecimal)
Byte Number 0 1 2 3 4 5 6 7 8 9 10 1211
Command
Action
Header Data
Header
code
Packet
Data
size
CRC
ag Action Type Setting
code
L H L H L H L H L H L H
<SET>
Change setting to
desired value [(cL)(cH)]
by [(bL)(bH)].
BEh EFh 03h 06h 00h
(aL) (aH) (cL) (cH)01h 00h (bL) (bH)
<GET>
Read projector
internal setup value [(bL)
(bH)] .
(aL) (aH) 02h 00h (bL) (bH) 00h 00h
<INCREMENT>
Increment setup value
[(bL)(bH)] by 1.
(aL) (aH) 04h 00h (bL) (bH) 00h 00h
<DECREMENT>
Decrement setup value
[(bL)(bH)] by 1.
(aL) (aH) 05h 00h (bL) (bH) 00h 00h
<EXECUTE> Run a
command [(bL)(bH)].
(aL) (aH) 06h 00h (bL) (bH) 00h 00h
[Header code] [Packet] [Data size]
Set [BEh, EFh, 03h, 06h, 00h] to byte number 0 to 4.
[CRC ag]
For byte number
5, 6,
refer to
RS-232C Communication / Network command
table
.(&17)
[Action]
Set functional code to byte number 7, 8.
<SET GET INCREMENT > = [01h, 00h], < > = [02h, 00h], < > = [04h, 00h]
<DECREMENT EXECUTE > = [05h, 00h], < > = [06h, 00h]
Refer to the Communication command table (&above).
[Type] [Setting code]
For byte number 9 to 12, refer to RS-232C Communication / Network
command table (&17).

LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016) 10
RS-232C Communication (continued)
3. Response code / Error code ("h" shows hexadecimal)
(1) ACK reply: 06h
When the projector receives the Set, Increment, Decrement or Execute
command correctly, the projector changes the setting data for the specied
item by [Type], and it returns the code.
(2) NAK reply: 15h
When the projector cannot understand the received command, the projector
returns the error code.
In such a case, check the sending code and send the same command again.
(3) Error reply: 1Ch + 0000h
When the projector cannot execute the received command for any reasons,
the projector returns the error code.
In such a case, check the sending code and the setting status of the projector.
(4) Data reply: 1Dh + xxxxh
When the projector receives the GET command correctly, the projector returns
the response code and 2 bytes of data.
NOTE • For connecting the projector to your devices, read the manual for
each devices, and connect them correctly with suitable cables.
• Operation cannot be guaranteed when the projector receives an undened
command or data.
• Provide an interval of at least 40ms between the response code and any
other code.
• The projector outputs test data when the power supply is switched ON, and
when the lamp is lit. Ignore this data.
• Commands are not accepted during warm-up.
• When the data length is greater than indicated by the data length code, the
projector ignore the excess data code. Conversely when the data length is
shorter than indicated by the data length code, the projector returns the error
code to the computer.

LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016) 11
When the projector connects network, the projector can be controlled with RS-
232C commands from the computer with web browser.
For details of RS-232C commands, refer to RS-232C Communication / Network
command table
( ).&17
Command Control via the Network
LAN
Connection
1. Turn off the projector and the computer.
2. If you use wired LAN, connect the projector's LAN HDBaseT or TM port to the
computer's LAN or HDBaseTTM port with a LAN cable. Use the cable that
ful lls the speci cation shown in gure. If you use wireless LAN, insert the USB
wireless adapter into the port of the projector.WIRELESS
3. Turn the computer on, and after the computer has started up turn the
projector on.
NOTE •
If data is transferred using wireless and wired LAN at the same time,
the projector may not be able to process the data correctly.
Command Control via the Network
• LAN cable (CAT-5e or greater)
or
• For HDBaseT connection
- CAT-5e or greater
- shielded type (connectors included)
- straight cable
- single cable
USB wireless adapter
WIRELESS port
LAN or
HDBaseT port

LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016) 12
Communication Port
The following two ports are assigned for the command control.
TCP #23
TCP #9715
Congure the following items from a web browser when command control is used.
Port Settings
Network Control
Port1 (Port: 23)
Port open
Click the checkbox to open [Enable] [Network
Control Port1 (Port: 23)] to use TCP #23.
Default setting is Enable.
Authentication
Click the checkbox for the [Enable]
[Authentication] setting when authentication
is required.
Default setting is Disable.
Network Control
Port2 (Port: 9715)
Port open
Click the checkbox to open [Enable] [Network
Control Port2 (Port: 9715)] to use TCP
#9715.
Default setting is Enable.
Authentication
Click the checkbox for the [Enable]
[Authentication] setting when authentication
is required.
Default setting is Enable.
Command Control via the Network
When the authentication setting is enabled, the following settings are required.
Security Settings
Network Control
Authentication
Password Enter the required authentication password.
Conrm this setting is the same for [Network
Control Port1 (Port: 23)] [Network and
Control Port2 (Port: 9715)].
Default setting is blank.
Re-enter
Authentication
Password

LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016) 13
Command Control via the Network (continued)
Command control settings
[TCP #23]
1. Command format
Same as RS-232C communication, refer to RS-232C Communication command format.
2. Response code / Error code ("h" shows hexadecimal)
Four of the response / error code used for TCP#23 are the same as RS-232C
Communication (1)~(4). One authentication error reply (5) is added.
(1) ACK reply : 06h
Refer to RS-232C communication (&8).
(2) NAK reply : 15h
Refer to RS-232C communication (&8).
(3) Error reply : 1Ch + 0000h
Refer to RS-232C communication (&8).
(4) Data reply : 1Dh + xxxxh
Refer to RS-232C communication (&8).
(5) Authentication error reply : 1Fh + 0400h
When authentication error occurred, the projector returns the error code.
[TCP #9715]
1. Command format
The commands some datum are added to the head and the end of the ones of
TCP#9715 are used.
Header RS-232C command Connection IDData length Check sum
0×02 0×0D 13 bytes 1 byte 1 byte
[Header]
02, Fixed
[Data Length]
RS-232C commands byte length (0×0D, Fixed)
[RS-232C commands]
Refer to RS-232C Communication command format (&9).
[Check Sum]
This is the value to make zero on the addition of the lower 8 bits from the header
to the checksum.
[Connection ID]
Random value from 0 to 255 (This value is attached to the reply data).
NOTE • Operation cannot be guaranteed when the projector receives an
undened command or data.
• Provide an interval of at least 40ms between the response code and any other
code.
• Commands are not accepted during warm-up.

LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016) 14
NOTE • As for the transmission of the second or subsequent commands, the
authentication data can be omitted for the same connection.
Command Control via the Network (continued)
2. Response code / Error code ("h" shows hexadecimal)
The connection ID is attached for the TCP#23's response / error codes are
used. The connection ID is same as the sending command format.
(1) ACK reply: 06h + ××h (××h : connection ID)
(2) NAK reply: 15h + ××h
(3) Error reply: 1Ch + 0000h + ××h
(4) Data reply: 1Dh + xxxxh + ××h
(5) Authentication error reply: 1Fh + 0400h + ××h
(6) Projector busy reply: 1Fh + ××××h + ××h
When the projector is too busy to receive the command, the projector returns
the error code.
In such a case, check the sending code and send the same command again.
Automatic Connection Break
The TCP connection is automatically disconnected after there is no communication
for 30 seconds after being established.
Authentication
The projector does not accept commands without authentication success
when authentication is enabled. The projector uses a challenge response type
authentication with an MD5 (Message Digest 5) algorithm.
When the projector is connected to a LAN, a random 8 bytes is returned if
authentication is enabled. Bind this received 8 bytes and the authentication
password, and digest the data with the MD5 algorithm, and add it in front of the
commands to send.
The following is a sample of authentication process.
Authentication password: password (example)
Random 8 bytes: a572f60c (example)
1) Select a projector and receive the random 8 bytes from the projector.
“a572f60c”
2) Bind the random 8 bytes and the authentication password.
“a572f60cpassword”
3) Digest this bound with MD5 algorithm.
“e3d97429adffa11bce1f7275813d4bde”
4) Add this code in front of the commands and send the data.
“e3d97429adffa11bce1f7275813d4bde” + [command].
5) When the sent data is correct, the command is performed and the reply data is
returned. Otherwise, an authentication error is returned.

LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016) 16
Communication settings
For communication setting, use the COMMUNICATION menu in the OPTION -
SERVICE menu.
Item Condition
BAUD RATE 4800bps / 9600bps / 19200bps / 38400bps
Data length 8 bit (xed)
PARITY NONE/ODD/EVEN
Start bit 1 bit (xed)
Stop bit 1 bit (xed)
Transmission method HALF-DUPLEX/FULL-DUPLEX
NOTE • For connecting the projector to your devices, read the manual for
each devices, and connect them correctly with suitable cables.
• Turn off the power and unplug both the projector and other devices before
connecting them.
• For details of Transmission method, refer to 7.4 Transmission method in the
Network Guide.
Network Bridge Communication

RS-232C Communication / Network command table (continued)
18
LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016)
Names Operation Type Header CRC Command Data
Action Type Setting code
PbyP
RIGHT SOURCE
Set
COMPUTER IN BE EF 03 06 00 86 27 01 00 12 23 00 00
HDMI 1 BE EF 03 06 00 76 27 01 00 12 23 03 00
HDMI 2 BE EF 03 06 00 16 23 01 00 12 23 0D 00
HDBaseT BE EF 03 06 00 D6 2B 01 00 12 23 11 00
VIDEO BE EF 03 06 00 16 26 01 00 12 23 01 00
Get BE EF 03 06 00 B5 27 02 00 12 23 00 00
PbyP
MAIN AREA
Set LEFT BE EF 03 06 00 7A 26 01 00 13 23 00 00
RIGHT BE EF 03 06 00 EA 27 01 00 13 23 01 00
Get BE EF 03 06 00 49 26 02 00 13 23 00 00
PbyP
LEFT SOURCE
Set
COMPUTER IN BE EF 03 06 00 F2 26 01 00 15 23 00 00
HDMI 1 BE EF 03 06 00 02 26 01 00 15 23 03 00
HDMI 2 BE EF 03 06 00 62 22 01 00 15 23 0D 00
HDBaseT BE EF 03 06 00 A2 2A 01 00 15 23 11 00
VIDEO BE EF 03 06 00 62 27 01 00 15 23 01 00
Get BE EF 03 06 00 C1 26 02 00 15 23 00 00
PIP POSITION Set
TOP LEFT BE EF 03 06 00 02 23 01 00 01 23 00 00
TOP RIGHT BE EF 03 06 00 92 22 01 00 01 23 01 00
BOTTOM LEFT BE EF 03 06 00 62 22 01 00 01 23 02 00
BOTTOM RIGHT BE EF 03 06 00 F2 23 01 00 01 23 03 00
Get BE EF 03 06 00 31 23 02 00 01 23 00 00
PIP
MAIN AREA
Set PRIMARY BE EF 03 06 00 32 22 01 00 05 23 00 00
SECONDARY BE EF 03 06 00 A2 23 01 00 05 23 01 00
Get BE EF 03 06 00 01 22 02 00 05 23 00 00
PIP PRIMARY
SOURCE
Set
COMPUTER IN BE EF 03 06 00 CE 23 01 00 04 23 00 00
HDMI 1 BE EF 03 06 00 3E 23 01 00 04 23 03 00
HDMI 2 BE EF 03 06 00 5E 27 01 00 04 23 0D 00
HDBaseT BE EF 03 06 00 9E 2F 01 00 04 23 11 00
VIDEO BE EF 03 06 00 5E 22 01 00 04 23 01 00
Get BE EF 03 06 00 FD 23 02 00 04 23 00 00
PIP
SECONDARY
SOURCE
Set
COMPUTER IN BE EF 03 06 00 46 23 01 00 02 23 00 00
HDMI 1 BE EF 03 06 00 B6 23 01 00 02 23 03 00
HDMI 2 BE EF 03 06 00 D6 27 01 00 02 23 0D 00
HDBaseT BE EF 03 06 00 16 2F 01 00 02 23 11 00
VIDEO BE EF 03 06 00 D6 22 01 00 02 23 01 00
Get BE EF 03 06 00 75 23 02 00 02 23 00 00
PbyP SWAP
Execute BE EF 03 06 00 01 27 06 00 16 23 00 00
PbyP / PIP
FRAME LOCK
Set LEFT / PRIMARY BE EF 03 06 00 4A 27 01 00 17 23 00 00
RIGHT / SECONDARY
BE EF 03 06 00 DA 26 01 00 17 23 01 00
Get BE EF 03 06 00 79 27 02 00 17 23 00 00

RS-232C Communication / Network command table (continued)
19
LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016)
Names Operation Type Header CRC Command Data
Action Type Setting code
PICTURE
MODE
Set
STANDARD BE EF 03 06 00 83 F5 01 00 BA 30 06 00
NATURAL BE EF 03 06 00 23 F6 01 00 BA 30 00 00
CINEMA BE EF 03 06 00 B3 F7 01 00 BA 30 01 00
DYNAMIC BE EF 03 06 00 E3 F4 01 00 BA 30 04 00
BOARD(BLACK) BE EF 03 06 00 E3 EF 01 00 BA 30 20 00
BOARD(GREEN) BE EF 03 06 00 73 EE 01 00 BA 30 21 00
WHITEBOARD BE EF 03 06 00 83 EE 01 00 BA 30 22 00
DAYTIME BE EF 03 06 00 E3 C7 01 00 BA 30 40 00
DICOM SIM. BE EF 03 06 00 73 C6 01 00 BA 30 41 00
USER-1 BE EF 03 06 00 E3 FB 01 00 BA 30 10 00
USER-2 BE EF 03 06 00 73 FA 01 00 BA 30 11 00
USER-3 BE EF 03 06 00 83 FA 01 00 BA 30 12 00
Get BE EF 03 06 00 10 F6 02 00 BA 30 00 00
BRIGHTNESS
Get BE EF 03 06 00 89 D2 02 00 03 20 00 00
Increment BE EF 03 06 00 EF D2 04 00 03 20 00 00
Decrement BE EF 03 06 00 3E D3 05 00 03 20 00 00
BRIGHTNESS
Reset Execute BE EF 03 06 00 58 D3 06 00 00 70 00 00
CONTRAST
Get BE EF 03 06 00 FD D3 02 00 04 20 00 00
Increment BE EF 03 06 00 9B D3 04 00 04 20 00 00
Decrement BE EF 03 06 00 4A D2 05 00 04 20 00 00
CONTRAST
Reset Execute BE EF 03 06 00 A4 D2 06 00 01 70 00 00
GAMMA Set
1 DEFAULT BE EF 03 06 00 07 E9 01 00 A1 30 20 00
1 CUSTOM BE EF 03 06 00 07 FD 01 00 A1 30 10 00
2 DEFAULT BE EF 03 06 00 97 E8 01 00 A1 30 21 00
2 CUSTOM BE EF 03 06 00 97 FC 01 00 A1 30 11 00
3 DEFAULT BE EF 03 06 00 67 E8 01 00 A1 30 22 00
3 CUSTOM BE EF 03 06 00 67 FC 01 00 A1 30 12 00
4 DEFAULT BE EF 03 06 00 F7 E9 01 00 A1 30 23 00
4 CUSTOM BE EF 03 06 00 F7 FD 01 00 A1 30 13 00
5 DEFAULT BE EF 03 06 00 C7 EB 01 00 A1 30 24 00
5 CUSTOM BE EF 03 06 00 C7 FF 01 00 A1 30 14 00
6 DEFAULT BE EF 03 06 00 57 EA 01 00 A1 30 25 00
6 CUSTOM BE EF 03 06 00 57 FE 01 00 A1 30 15 00
7 DEFAULT BE EF 03 06 00 A7 EA 01 00 A1 30 26 00
7 CUSTOM BE EF 03 06 00 A7 FE 01 00 A1 30 16 00
8 DEFAULT BE EF 03 06 00 37 EB 01 00 A1 30 27 00
8 CUSTOM BE EF 03 06 00 37 FF 01 00 A1 30 17 00
Get BE EF 03 06 00 F4 F0 02 00 A1 30 00 00

RS-232C Communication / Network command table (continued)
20
LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016)
Names Operation Type Header CRC Command Data
Action Type Setting code
User GAMMA
Point 1
Get BE EF 03 06 00 08 FE 02 00 90 30 00 00
Increment BE EF 03 06 00 6E FE 04 00 90 30 00 00
Decrement BE EF 03 06 00 BF FF 05 00 90 30 00 00
User GAMMA
Point 1 Reset Execute BE EF 03 06 00 58 C2 06 00 50 70 00 00
User GAMMA
Point 2
Get BE EF 03 06 00 F4 FF 02 00 91 30 00 00
Increment BE EF 03 06 00 92 FF 04 00 91 30 00 00
Decrement BE EF 03 06 00 43 FE 05 00 91 30 00 00
User GAMMA
Point 2 Reset Execute BE EF 03 06 00 A4 C3 06 00 51 70 00 00
User GAMMA
Point 3
Get BE EF 03 06 00 B0 FF 02 00 92 30 00 00
Increment BE EF 03 06 00 D6 FF 04 00 92 30 00 00
Decrement BE EF 03 06 00 07 FE 05 00 92 30 00 00
User GAMMA
Point 3 Reset Execute BE EF 03 06 00 E0 C3 06 00 52 70 00 00
User GAMMA
Point 4
Get BE EF 03 06 00 4C FE 02 00 93 30 00 00
Increment BE EF 03 06 00 2A FE 04 00 93 30 00 00
Decrement BE EF 03 06 00 FB FF 05 00 93 30 00 00
User GAMMA
Point 4 Reset Execute BE EF 03 06 00 1C C2 06 00 53 70 00 00
User GAMMA
Point 5
Get BE EF 03 06 00 38 FF 02 00 94 30 00 00
Increment BE EF 03 06 00 5E FF 04 00 94 30 00 00
Decrement BE EF 03 06 00 8F FE 05 00 94 30 00 00
User GAMMA
Point 5 Reset Execute BE EF 03 06 00 68 C3 06 00 54 70 00 00
User GAMMA
Point 6
Get BE EF 03 06 00 C4 FE 02 00 95 30 00 00
Increment BE EF 03 06 00 A2 FE 04 00 95 30 00 00
Decrement BE EF 03 06 00 73 FF 05 00 95 30 00 00
User GAMMA
Point 6 Reset Execute BE EF 03 06 00 94 C2 06 00 55 70 00 00
User GAMMA
Point 7
Get BE EF 03 06 00 80 FE 02 00 96 30 00 00
Increment BE EF 03 06 00 E6 FE 04 00 96 30 00 00
Decrement BE EF 03 06 00 37 FF 05 00 96 30 00 00
User GAMMA
Point 7 Reset Execute BE EF 03 06 00 D0 C2 06 00 56 70 00 00
User GAMMA
Point 8
Get BE EF 03 06 00 7C FF 02 00 97 30 00 00
Increment BE EF 03 06 00 1A FF 04 00 97 30 00 00
Decrement BE EF 03 06 00 CB FE 05 00 97 30 00 00
User GAMMA
Point 8 Reset Execute BE EF 03 06 00 2C C3 06 00 57 70 00 00

RS-232C Communication / Network command table (continued)
21
LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016)
Names Operation Type Header CRC Command Data
Action Type Setting code
COLOR TEMP Set
1 HIGH BE EF 03 06 00 0B F5 01 00 B0 30 03 00
1 CUSTOM
(HIGH) BE EF 03 06 00 CB F8 01 00 B0 30 13 00
2 MID-1 BE EF 03 06 00 9B F4 01 00 B0 30 02 00
2 CUSTOM
(MID-1) BE EF 03 06 00 5B F9 01 00 B0 30 12 00
3 MID-2 BE EF 03 06 00 3B F7 01 00 B0 30 04 00
3 CUSTOM
(MID-2) BE EF 03 06 00 FB FA 01 00 B0 30 14 00
3 LOW BE EF 03 06 00 6B F4 01 00 B0 30 01 00
4 CUSTOM(LOW) BE EF 03 06 00 AB F9 01 00 B0 30 11 00
4 Hi-BRIGHT-1 BE EF 03 06 00 3B F2 01 00 B0 30 08 00
5 CUSTOM BE EF 03 06 00 FB FF 01 00 B0 30 18 00
5 Hi-BRIGHT-2 BE EF 03 06 00 AB F3 01 00 B0 30 09 00
6 CUSTOM BE EF 03 06 00 6B FE 01 00 B0 30 19 00
6 Hi-BRIGHT-3 BE EF 03 06 00 5B F3 01 00 B0 30 0A 00
7 CUSTOM BE EF 03 06 00 9B FE 01 00 B0 30 1A 00
Get BE EF 03 06 00 C8 F5 02 00 B0 30 00 00
COLOR TEMP
GAIN R
Get BE EF 03 06 00 34 F4 02 00 B1 30 00 00
Increment BE EF 03 06 00 52 F4 04 00 B1 30 00 00
Decrement BE EF 03 06 00 83 F5 05 00 B1 30 00 00
COLOR TEMP
GAIN R Reset Execute BE EF 03 06 00 10 C6 06 00 46 70 00 00
COLOR TEMP
GAIN G
Get BE EF 03 06 00 70 F4 02 00 B2 30 00 00
Increment BE EF 03 06 00 16 F4 04 00 B2 30 00 00
Decrement BE EF 03 06 00 C7 F5 05 00 B2 30 00 00
COLOR TEMP
GAIN G Reset Execute BE EF 03 06 00 EC C7 06 00 47 70 00 00
COLOR TEMP
GAIN B
Get BE EF 03 06 00 8C F5 02 00 B3 30 00 00
Increment BE EF 03 06 00 EA F5 04 00 B3 30 00 00
Decrement BE EF 03 06 00 3B F4 05 00 B3 30 00 00
COLOR TEMP
GAIN B Reset Execute BE EF 03 06 00 F8 C4 06 00 48 70 00 00
COLOR TEMP
OFFSET R
Get BE EF 03 06 00 04 F5 02 00 B5 30 00 00
Increment BE EF 03 06 00 62 F5 04 00 B5 30 00 00
Decrement BE EF 03 06 00 B3 F4 05 00 B5 30 00 00
COLOR TEMP
OFFSET R Reset
Execute BE EF 03 06 00 40 C5 06 00 4A 70 00 00
COLOR TEMP
OFFSET G
Get BE EF 03 06 00 40 F5 02 00 B6 30 00 00
Increment BE EF 03 06 00 26 F5 04 00 B6 30 00 00
Decrement BE EF 03 06 00 F7 F4 05 00 B6 30 00 00
COLOR TEMP
OFFSET G Reset
Execute BE EF 03 06 00 BC C4 06 00 4B 70 00 00
COLOR TEMP
OFFSET B
Get BE EF 03 06 00 BC F4 02 00 B7 30 00 00
Increment BE EF 03 06 00 DA F4 04 00 B7 30 00 00
Decrement BE EF 03 06 00 0B F5 05 00 B7 30 00 00
COLOR TEMP
OFFSET B Reset
Execute BE EF 03 06 00 C8 C5 06 00 4C 70 00 00

RS-232C Communication / Network command table (continued)
22
LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016)
Names Operation Type Header CRC Command Data
Action Type Setting code
COLOR
Get BE EF 03 06 00 B5 72 02 00 02 22 00 00
Increment BE EF 03 06 00 D3 72 04 00 02 22 00 00
Decrement BE EF 03 06 00 02 73 05 00 02 22 00 00
COLOR Reset Execute BE EF 03 06 00 80 D0 06 00 0A 70 00 00
TINT
Get BE EF 03 06 00 49 73 02 00 03 22 00 00
Increment BE EF 03 06 00 2F 73 04 00 03 22 00 00
Decrement BE EF 03 06 00 FE 72 05 00 03 22 00 00
TINT Reset Execute BE EF 03 06 00 7C D1 06 00 0B 70 00 00
SHARPNESS
Get BE EF 03 06 00 F1 72 02 00 01 22 00 00
Increment BE EF 03 06 00 97 72 04 00 01 22 00 00
Decrement BE EF 03 06 00 46 73 05 00 01 22 00 00
SHARPNESS
Reset Execute BE EF 03 06 00 C4 D0 06 00 09 70 00 00
eClarity
Get BE EF 03 06 00 5D 70 02 00 0C 22 00 00
Increment BE EF 03 06 00 3B 70 04 00 0C 22 00 00
Decrement BE EF 03 06 00 EA 71 05 00 0C 22 00 00
eClarity Reset Execute BE EF 03 06 00 C8 DB 06 00 2C 70 00 00
HDCR
Get BE EF 03 06 00 A1 71 02 00 0D 22 00 00
Increment BE EF 03 06 00 C7 71 04 00 0D 22 00 00
Decrement BE EF 03 06 00 16 70 05 00 0D 22 00 00
HDCR Reset Execute BE EF 03 06 00 34 DA 06 00 2D 70 00 00
DYNAMIC IRIS Set
OFF BE EF 03 06 00 0B 22 01 00 04 33 00 00
THEATER BE EF 03 06 00 CB 2F 01 00 04 33 10 00
PRESENTATION BE EF 03 06 00 5B 2E 01 00 04 33 11 00
Get BE EF 03 06 00 38 22 02 00 04 33 00 00
MY MEMORY
Load Set
1 BE EF 03 06 00 0E D7 01 00 14 20 00 00
2 BE EF 03 06 00 9E D6 01 00 14 20 01 00
3 BE EF 03 06 00 6E D6 01 00 14 20 02 00
4 BE EF 03 06 00 FE D7 01 00 14 20 03 00
MY MEMORY
Save Set
1 BE EF 03 06 00 F2 D6 01 00 15 20 00 00
2 BE EF 03 06 00 62 D7 01 00 15 20 01 00
3 BE EF 03 06 00 92 D7 01 00 15 20 02 00
4 BE EF 03 06 00 02 D6 01 00 15 20 03 00
ASPECT Set
NORMAL BE EF 03 06 00 5E DD 01 00 08 20 10 00
4:3 BE EF 03 06 00 9E D0 01 00 08 20 00 00
16:9 BE EF 03 06 00 0E D1 01 00 08 20 01 00
16:10 BE EF 03 06 00 3E D6 01 00 08 20 0A 00
14:9 BE EF 03 06 00 CE D6 01 00 08 20 09 00
NATIVE BE EF 03 06 00 5E D7 01 00 08 20 08 00
ZOOM BE EF 03 06 00 9E C4 01 00 08 20 30 00
Get BE EF 03 06 00 AD D0 02 00 08 20 00 00
OVER SCAN
Get BE EF 03 06 00 91 70 02 00 09 22 00 00
Increment BE EF 03 06 00 F7 70 04 00 09 22 00 00
Decrement BE EF 03 06 00 26 71 05 00 09 22 00 00
OVER SCAN
Reset Execute BE EF 03 06 00 EC D9 06 00 27 70 00 00

RS-232C Communication / Network command table (continued)
23
LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016)
Names Operation Type Header CRC Command Data
Action Type Setting code
V POSITION
Get BE EF 03 06 00 0D 83 02 00 00 21 00 00
Increment BE EF 03 06 00 6B 83 04 00 00 21 00 00
Decrement BE EF 03 06 00 BA 82 05 00 00 21 00 00
V POSITION
Reset Execute BE EF 03 06 00 E0 D2 06 00 02 70 00 00
H POSITION
Get BE EF 03 06 00 F1 82 02 00 01 21 00 00
Increment BE EF 03 06 00 97 82 04 00 01 21 00 00
Decrement BE EF 03 06 00 46 83 05 00 01 21 00 00
H POSITION
Reset Execute BE EF 03 06 00 1C D3 06 00 03 70 00 00
H PHASE
Get BE EF 03 06 00 49 83 02 00 03 21 00 00
Increment BE EF 03 06 00 2F 83 04 00 03 21 00 00
Decrement BE EF 03 06 00 FE 82 05 00 03 21 00 00
H SIZE
Get BE EF 03 06 00 B5 82 02 00 02 21 00 00
Increment BE EF 03 06 00 D3 82 04 00 02 21 00 00
Decrement BE EF 03 06 00 02 83 05 00 02 21 00 00
H SIZE Reset Execute BE EF 03 06 00 68 D2 06 00 04 70 00 00
AUTO IMAGE Execute BE EF 03 06 00 91 D0 06 00 0A 20 00 00
PROGRESSIVE
Set
OFF BE EF 03 06 00 4A 72 01 00 07 22 00 00
TV BE EF 03 06 00 DA 73 01 00 07 22 01 00
FILM BE EF 03 06 00 2A 73 01 00 07 22 02 00
Get BE EF 03 06 00 79 72 02 00 07 22 00 00
VIDEO NR Set
LOW BE EF 03 06 00 26 72 01 00 06 22 01 00
MID BE EF 03 06 00 D6 72 01 00 06 22 02 00
HIGH BE EF 03 06 00 46 73 01 00 06 22 03 00
Get BE EF 03 06 00 85 73 02 00 06 22 00 00
COLOR SPACE Set
AUTO BE EF 03 06 00 0E 72 01 00 04 22 00 00
RGB BE EF 03 06 00 9E 73 01 00 04 22 01 00
SMPTE240 BE EF 03 06 00 6E 73 01 00 04 22 02 00
REC709 BE EF 03 06 00 FE 72 01 00 04 22 03 00
REC601 BE EF 03 06 00 CE 70 01 00 04 22 04 00
Get BE EF 03 06 00 3D 72 02 00 04 22 00 00
C-VIDEO
FORMAT
Set
AUTO BE EF 03 06 00 A2 70 01 00 11 22 0A 00
NTSC BE EF 03 06 00 C2 74 01 00 11 22 04 00
PAL BE EF 03 06 00 52 75 01 00 11 22 05 00
SECAM BE EF 03 06 00 52 70 01 00 11 22 09 00
NTSC4.43 BE EF 03 06 00 62 77 01 00 11 22 02 00
M-PAL BE EF 03 06 00 C2 71 01 00 11 22 08 00
N-PAL BE EF 03 06 00 32 74 01 00 11 22 07 00
Get BE EF 03 06 00 31 76 02 00 11 22 00 00
HDMI 1
FORMAT
Set
AUTO BE EF 03 06 00 BA 77 01 00 13 22 00 00
VIDEO BE EF 03 06 00 2A 76 01 00 13 22 01 00
COMPUTER BE EF 03 06 00 DA 76 01 00 13 22 02 00
Get BE EF 03 06 00 89 77 02 00 13 22 00 00
HDMI 2
FORMAT
Set
AUTO BE EF 03 06 00 52 75 01 00 1D 22 00 00
VIDEO BE EF 03 06 00 C2 74 01 00 1D 22 01 00
COMPUTER BE EF 03 06 00 32 74 01 00 1D 22 02 00
Get BE EF 03 06 00 61 75 02 00 1D 22 00 00

RS-232C Communication / Network command table (continued)
24
LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016)
Names Operation Type Header CRC Command Data
Action Type Setting code
HDBaseT
FORMAT
Set
AUTO BE EF 03 06 00 7A EA 01 00 D3 20 00 00
VIDEO BE EF 03 06 00 EA EB 01 00 D3 20 01 00
COMPUTER BE EF 03 06 00 1A EB 01 00 D3 20 02 00
Get BE EF 03 06 00 49 EA 02 00 D3 20 00 00
HDMI 1
RANGE
Set
AUTO BE EF 03 06 00 86 D8 01 00 22 20 00 00
NORMAL BE EF 03 06 00 16 D9 01 00 22 20 01 00
ENHANCED BE EF 03 06 00 E6 D9 01 00 22 20 02 00
Get BE EF 03 06 00 B5 D8 02 00 22 20 00 00
HDMI 2
RANGE
Set
AUTO BE EF 03 06 00 7A D9 01 00 23 20 00 00
NORMAL BE EF 03 06 00 EA D8 01 00 23 20 01 00
ENHANCED BE EF 03 06 00 1A D8 01 00 23 20 02 00
Get BE EF 03 06 00 49 D9 02 00 23 20 00 00
HDBaseT
RANGE
Set
AUTO BE EF 03 06 00 86 EB 01 00 D2 20 00 00
NORMAL BE EF 03 06 00 16 EA 01 00 D2 20 01 00
ENHANCED BE EF 03 06 00 E6 EA 01 00 D2 20 02 00
Get BE EF 03 06 00 B5 EB 02 00 D2 20 00 00
COMPUTER IN
Set AUTO BE EF 03 06 00 CE D6 01 00 10 20 03 00
SYNC ON G OFF BE EF 03 06 00 5E D7 01 00 10 20 02 00
Get BE EF 03 06 00 0D D6 02 00 10 20 00 00
FRAME LOCK -
COMPUTER IN
Set OFF BE EF 03 06 00 3B C2 01 00 50 30 00 00
ON BE EF 03 06 00 AB C3 01 00 50 30 01 00
Get BE EF 03 06 00 08 C2 02 00 50 30 00 00
FRAME LOCK -
HDMI 1
Set OFF BE EF 03 06 00 7F C2 01 00 53 30 00 00
ON BE EF 03 06 00 EF C3 01 00 53 30 01 00
Get BE EF 03 06 00 4C C2 02 00 53 30 00 00
FRAME LOCK -
HDMI 2
Set OFF BE EF 03 06 00 97 C0 01 00 5D 30 00 00
ON BE EF 03 06 00 07 C1 01 00 5D 30 01 00
Get BE EF 03 06 00 A4 C0 02 00 5D 30 00 00
FRAME LOCK -
HDBaseT
Set OFF BE EF 03 06 00 C2 EB 01 00 D1 20 00 00
ON BE EF 03 06 00 52 EA 01 00 D1 20 01 00
Get BE EF 03 06 00 F1 EB 02 00 D1 20 00 00

RS-232C Communication / Network command table (continued)
26
LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016)
Names Operation Type Header CRC Command Data
Action Type Setting code
3D KEYSTONE
Left Bottom - H
Get BE EF 03 06 00 01 88 02 00 25 21 00 00
Increment BE EF 03 06 00 67 88 04 00 25 21 00 00
Decrement BE EF 03 06 00 B6 89 05 00 25 21 00 00
3D KEYSTONE
Left Bottom - V
Get BE EF 03 06 00 45 88 02 00 26 21 00 00
Increment BE EF 03 06 00 23 88 04 00 26 21 00 00
Decrement BE EF 03 06 00 F2 89 05 00 26 21 00 00
3D KEYSTONE
Right Bottom - H
Get BE EF 03 06 00 B9 89 02 00 27 21 00 00
Increment BE EF 03 06 00 DF 89 04 00 27 21 00 00
Decrement BE EF 03 06 00 0E 88 05 00 27 21 00 00
3D KEYSTONE
Right Bottom - V
Get BE EF 03 06 00 AD 8A 02 00 28 21 00 00
Increment BE EF 03 06 00 CB 8A 04 00 28 21 00 00
Decrement BE EF 03 06 00 1A 8B 05 00 28 21 00 00
3D KEYSTONE
All Corners Reset
Execute BE EF 03 06 00 D5 8A 06 00 29 21 00 00
3D KEYSTONE
Left Side
Distortion
Get BE EF 03 06 00 31 97 02 00 41 21 00 00
Increment BE EF 03 06 00 57 97 04 00 41 21 00 00
Decrement BE EF 03 06 00 86 96 05 00 41 21 00 00
3D KEYSTONE
Right Side
Distortion
Get BE EF 03 06 00 75 97 02 00 42 21 00 00
Increment BE EF 03 06 00 13 97 04 00 42 21 00 00
Decrement BE EF 03 06 00 C2 96 05 00 42 21 00 00
3D KEYSTONE
Top Side
Distortion
Get BE EF 03 06 00 FD 97 02 00 44 21 00 00
Increment BE EF 03 06 00 9B 97 04 00 44 21 00 00
Decrement BE EF 03 06 00 4A 96 05 00 44 21 00 00
3D KEYSTONE
Bottom Side
Distortion
Get BE EF 03 06 00 01 96 02 00 45 21 00 00
Increment BE EF 03 06 00 67 96 04 00 45 21 00 00
Decrement BE EF 03 06 00 B6 97 05 00 45 21 00 00
3D KEYSTONE
All Sides Reset
Execute BE EF 03 06 00 3D 96 06 00 47 21 00 00
3D KEYSTONE
Memory Save-1 Execute BE EF 03 06 00 29 95 06 00 48 21 00 00
3D KEYSTONE
Memory Save-2 Execute BE EF 03 06 00 D5 94 06 00 49 21 00 00
3D KEYSTONE
Memory Save-3 Execute BE EF 03 06 00 91 94 06 00 4A 21 00 00
3D KEYSTONE
Memory Load-1 Execute BE EF 03 06 00 6D 95 06 00 4B 21 00 00
3D KEYSTONE
Memory Load-2 Execute BE EF 03 06 00 19 94 06 00 4C 21 00 00
3D KEYSTONE
Memory Load-3 Execute BE EF 03 06 00 E5 95 06 00 4D 21 00 00

RS-232C Communication / Network command table (continued)
27
LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016)
Names Operation Type Header CRC Command Data
Action Type Setting code
EDGE
BLENDING
MODE
Set OFF BE EF 03 06 00 6B 94 01 00 4C 31 00 00
MANUAL BE EF 03 06 00 FB 95 01 00 4C 31 01 00
Get BE EF 03 06 00 58 94 02 00 4C 31 00 00
EDGE BLENDING
REGION Reset
Execute BE EF 03 06 00 8C 96 06 00 40 31 00 00
EDGE BLENDING
LEVEL
Increment BE EF 03 06 00 92 96 04 00 41 31 00 00
Decrement BE EF 03 06 00 43 97 05 00 41 31 00 00
Get BE EF 03 06 00 F4 96 02 00 41 31 00 00
EDGE BLENDING
LEFT
Get BE EF 03 06 00 68 95 02 00 48 31 00 00
Increment BE EF 03 06 00 0E 95 04 00 48 31 00 00
Decrement BE EF 03 06 00 DF 94 05 00 48 31 00 00
EDGE BLENDING
RIGHT
Get BE EF 03 06 00 94 94 02 00 49 31 00 00
Increment BE EF 03 06 00 F2 94 04 00 49 31 00 00
Decrement BE EF 03 06 00 23 95 05 00 49 31 00 00
EDGE BLENDING
TOP
Get BE EF 03 06 00 D0 94 02 00 4A 31 00 00
Increment BE EF 03 06 00 B6 94 04 00 4A 31 00 00
Decrement BE EF 03 06 00 67 95 05 00 4A 31 00 00
EDGE BLENDING
BOTTOM
Get BE EF 03 06 00 2C 95 02 00 4B 31 00 00
Increment BE EF 03 06 00 4A 95 04 00 4B 31 00 00
Decrement BE EF 03 06 00 9B 94 05 00 4B 31 00 00
CROPPING
MODE
Set OFF BE EF 03 06 00 FB 93 01 00 50 31 00 00
ON BE EF 03 06 00 6B 92 01 00 50 31 01 00
Get BE EF 03 06 00 C8 93 02 00 50 31 00 00
CROPPING
SETUP X
Get BE EF 03 06 00 A8 91 02 00 58 31 00 00
Increment BE EF 03 06 00 CE 91 04 00 58 31 00 00
Decrement BE EF 03 06 00 1F 90 05 00 58 31 00 00
CROPPING
SETUP Y
Get BE EF 03 06 00 54 90 02 00 59 31 00 00
Increment BE EF 03 06 00 32 90 04 00 59 31 00 00
Decrement BE EF 03 06 00 E3 91 05 00 59 31 00 00
CROPPING
SETUP W
Get BE EF 03 06 00 10 90 02 00 5A 31 00 00
Increment BE EF 03 06 00 76 90 04 00 5A 31 00 00
Decrement BE EF 03 06 00 A7 91 05 00 5A 31 00 00
CROPPING
SETUP H
Get BE EF 03 06 00 EC 91 02 00 5B 31 00 00
Increment BE EF 03 06 00 8A 91 04 00 5B 31 00 00
Decrement BE EF 03 06 00 5B 90 05 00 5B 31 00 00
CROPPING Apply
Execute BE EF 03 06 00 B0 93 06 00 51 31 00 00
CROPPING Reset
Execute BE EF 03 06 00 F4 93 06 00 52 31 00 00
WARPING
MODE
Set
OFF BE EF 03 06 00 FB 9C 01 00 60 31 00 00
MODE-1 BE EF 03 06 00 6B 9D 01 00 60 31 01 00
MODE-2 BE EF 03 06 00 9B 9D 01 00 60 31 02 00
MODE-3 BE EF 03 06 00 0B 9C 01 00 60 31 03 00
Get BE EF 03 06 00 C8 9C 02 00 60 31 00 00
Dimming
Level
Get BE EF 03 06 00 7C 22 02 00 07 33 00 00
Increment BE EF 03 06 00 1A 22 04 00 07 33 00 00
Decrement BE EF 03 06 00 CB 23 05 00 07 33 00 00

RS-232C Communication / Network command table (continued)
28
LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016)
Names Operation Type Header CRC Command Data
Action Type Setting code
WHITE
BALANCE
OFFSET R
Get BE EF 03 06 00 0C 72 02 00 50 27 00 00
Increment BE EF 03 06 00 6A 72 04 00 50 27 00 00
Decrement BE EF 03 06 00 BB 73 05 00 50 27 00 00
WHITE
BALANCE
OFFSET R
Reset
Execute BE EF 03 06 00 38 E2 06 00 F8 70 00 00
WHITE
BALANCE
OFFSET G
Get BE EF 03 06 00 F0 73 02 00 51 27 00 00
Increment BE EF 03 06 00 96 73 04 00 51 27 00 00
Decrement BE EF 03 06 00 47 72 05 00 51 27 00 00
WHITE
BALANCE
OFFSET G
REset
Execute BE EF 03 06 00 C4 E3 06 00 F9 70 00 00
WHITE
BALANCE
OFFSET B
Get BE EF 03 06 00 B4 73 02 00 52 27 00 00
Increment BE EF 03 06 00 D2 73 04 00 52 27 00 00
Decrement BE EF 03 06 00 03 72 05 00 52 27 00 00
WHITE
BALANCE
OFFSET B
Reset
Execute BE EF 03 06 00 80 E3 06 00 00 00FA 70
WHITE
BALANCE GAIN
R
Get BE EF 03 06 00 3C 73 02 00 54 27 00 00
Increment BE EF 03 06 00 5A 73 04 00 54 27 00 00
Decrement BE EF 03 06 00 8B 72 05 00 54 27 00 00
WHITE
BALANCE GAIN
R Reset
Execute BE EF 03 06 00 08 E3 06 00 FC 70 00 00
WHITE
BALANCE GAIN
G
Get BE EF 03 06 00 C0 72 02 00 55 27 00 00
Increment BE EF 03 06 00 A6 72 04 00 55 27 00 00
Decrement BE EF 03 06 00 77 73 05 00 55 27 00 00
WHITE
BALANCE GAIN
G Reset
Execute BE EF 03 06 00 F4 E2 06 00 FD 70 00 00
WHITE
BALANCE GAIN
B
Get BE EF 03 06 00 84 72 02 00 56 27 00 00
Increment BE EF 03 06 00 E2 72 04 00 56 27 00 00
Decrement BE EF 03 06 00 33 73 05 00 56 27 00 00
WHITE
BALANCE GAIN
B Reset
Execute BE EF 03 06 00 B0 E2 06 00 FE 70 00 00

RS-232C Communication / Network command table (continued)
29
LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016)
Names Operation Type Header CRC Command Data
Action Type Setting code
HDCR LiteLoc Set OFF BE EF 03 06 00 D6 71 01 00 0E 22 00 00
ON BE EF 03 06 00 46 70 01 00 0E 22 01 00
Get BE EF 03 06 00 E5 71 02 00 0E 22 00 00
ECO MODE Set NORMAL BE EF 03 06 00 3B 23 01 00 00 33 00 00
ECO BE EF 03 06 00 AB 22 01 00 00 33 01 00
Get BE EF 03 06 00 08 23 02 00 00 33 00 00
INSTALLATION Set
FRONT / DESKTOP
BE EF 03 06 00 C7 D2 01 00 01 30 00 00
REAR / DESKTOP
BE EF 03 06 00 57 D3 01 00 01 30 01 00
REAR / CEILING
BE EF 03 06 00 A7 D3 01 00 01 30 02 00
FRONT / CEILING
BE EF 03 06 00 37 D2 01 00 01 30 03 00
Get BE EF 03 06 00 F4 D2 02 00 01 30 00 00
STANDBY
MODE
Set NORMAL BE EF 03 06 00 D6 D2 01 00 01 60 00 00
POWER SAVE BE EF 03 06 00 46 D3 01 00 01 60 01 00
Get BE EF 03 06 00 E5 D2 02 00 01 60 00 00
COLOR
UNIFORMITY
LEVEL
Set
1
BE EF 03 06 00 AF 6D 01 00 30 27 01 00
2
BE EF 03 06 00 5F 6D 01 00 30 27 02 00
3
BE EF 03 06 00 CF 6C 01 00 30 27 03 00
4
BE EF 03 06 00 FF 6E 01 00 30 27 04 00
Get BE EF 03 06 00 0C 6C 02 00 30 27 00 00
COLOR
UNIFORMITY
AREA
Set
Top Left
BE EF 03 06 00 C3 6D 01 00 31 27 00 00
Top
BE EF 03 06 00 53 6C 01 00 31 27 01 00
Top Right
BE EF 03 06 00 A3 6C 01 00 31 27 02 00
Left
BE EF 03 06 00 01 00 31 27 00 0103 AC
All
BE EF 03 06 00 01 00 31 27 01 0193 AD
Right
BE EF 03 06 00 01 00 31 27 02 0163 AD
Bottom Left
BE EF 03 06 00 02 EC 01 00 31 27 00 02
Bottom
BE EF 03 06 00 92 ED 01 00 31 27 01 02
Bottom Right
BE EF 03 06 00 62 ED 01 00 31 27 02 02
Get BE EF 03 06 00 F0 6D 02 00 31 27 00 00
COLOR
UNIFORMITY R
Get BE EF 03 06 00 B4 6D 02 00 32 27 00 00
Increment BE EF 03 06 00 D2 6D 04 00 32 27 00 00
Decrement BE EF 03 06 00 03 6C 05 00 32 27 00 00
COLOR UNIFORMITY
R Reset
Execute BE EF 03 06 00 58 E0 06 00 F0 70 00 00
COLOR
UNIFORMITY G
Get BE EF 03 06 00 48 6C 02 00 33 27 00 00
Increment BE EF 03 06 00 2E 6C 04 00 33 27 00 00
Decrement BE EF 03 06 00 FF 6D 05 00 33 27 00 00
COLOR UNIFORMITY
G Reset
Execute BE EF 03 06 00 A4 E1 06 00 F1 70 00 00
COLOR
UNIFORMITY B
Get BE EF 03 06 00 3C 6D 02 00 34 27 00 00
Increment BE EF 03 06 00 5A 6D 04 00 34 27 00 00
Decrement BE EF 03 06 00 8B 6C 05 00 34 27 00 00
COLOR UNIFORMITY
B Reset
Execute BE EF 03 06 00 E0 E1 06 00 F2 70 00 00

RS-232C Communication / Network command table (continued)
30
LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016)
RS-232C Communication / Network command table (continued)
Names Operation Type Header CRC Command Data
Action Type Setting code
COLOR UNIFORMITY
ALL Reset
Execute BE EF 03 06 00 1C E0 06 00 F3 70 00 00
COLOR UNIFORMITY
PATTERN
Set OFF BE EF 03 06 00 B7 6C 01 00 36 27 00 00
ON BE EF 03 06 00 27 6D 01 00 36 27 01 00
Get BE EF 03 06 00 84 6C 02 00 36 27 00 00
VOLUME -
COMPUTER IN
Get BE EF 03 06 00 CD CC 02 00 60 20 00 00
Increment BE EF 03 06 00 AB CC 04 00 60 20 00 00
Decrement BE EF 03 06 00 7A CD 05 00 60 20 00 00
VOLUME - LAN
Get BE EF 03 06 00 E9 CE 02 00 6B 20 00 00
Increment BE EF 03 06 00 8F CE 04 00 6B 20 00 00
Decrement BE EF 03 06 00 5E CF 05 00 6B 20 00 00
VOLUME -
HDMI 1
Get BE EF 03 06 00 89 CC 02 00 63 20 00 00
Increment BE EF 03 06 00 EF CC 04 00 63 20 00 00
Decrement BE EF 03 06 00 3E CD 05 00 63 20 00 00
VOLUME -
HDMI 2
Get BE EF 03 06 00 61 CE 02 00 6D 20 00 00
Increment BE EF 03 06 00 07 CE 04 00 6D 20 00 00
Decrement BE EF 03 06 00 D6 CF 05 00 6D 20 00 00
VOLUME -
HDBaseT
Get BE EF 03 06 00 C1 EA 02 00 D5 20 00 00
Increment BE EF 03 06 00 A7 EA 04 00 D5 20 00 00
Decrement BE EF 03 06 00 76 EB 05 00 D5 20 00 00
VOLUME -
VIDEO
Get BE EF 03 06 00 31 CD 02 00 61 20 00 00
Increment BE EF 03 06 00 57 CD 04 00 61 20 00 00
Decrement BE EF 03 06 00 86 CC 05 00 61 20 00 00
VOLUME -
STANDBY
Get BE EF 03 06 00 D9 CF 02 00 6F 20 00 00
Increment BE EF 03 06 00 BF CF 04 00 6F 20 00 00
Decrement BE EF 03 06 00 6E CE 05 00 6F 20 00 00
VOLUME - ALL
Get BE EF 03 06 00 CD C3 02 00 50 20 00 00
Increment BE EF 03 06 00 AB C3 04 00 50 20 00 00
Decrement BE EF 03 06 00 7A C2 05 00 50 20 00 00
MUTE Set OFF BE EF 03 06 00 46 D3 01 00 02 20 00 00
ON BE EF 03 06 00 D6 D2 01 00 02 20 01 00
Get BE EF 03 06 00 75 D3 02 00 02 20 00 00
AV MUTE Set OFF BE EF 03 06 00 FE F0 01 00 A0 20 00 00
ON BE EF 03 06 00 6E F1 01 00 A0 20 01 00
Get BE EF 03 06 00 CD F0 02 00 A0 20 00 00
SPEAKER Set OFF BE EF 03 06 00 6E D5 01 00 1C 20 00 00
ON BE EF 03 06 00 FE D4 01 00 1C 20 01 00
Get BE EF 03 06 00 5D D5 02 00 1C 20 00 00

RS-232C Communication / Network command table (continued)
31
LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016)
RS-232C Communication / Network command table (continued)
Names Operation Type Header CRC Command Data
Action Type Setting code
AUDIO
SOURCE -
COMPUTER IN
Set
AUDIO IN1 BE EF 03 06 00 6E DC 01 00 30 20 01 00
AUDIO IN2 BE EF 03 06 00 9E DC 01 00 30 20 02 00
OFF BE EF 03 06 00 FE DD 01 00 30 20 00 00
Get BE EF 03 06 00 CD DD 02 00 30 20 00 00
AUDIO
SOURCE -
LAN
Set
AUDIO IN1 BE EF 03 06 00 4A DE 01 00 3B 20 01 00
AUDIO IN2 BE EF 03 06 00 BA DE 01 00 3B 20 02 00
AUDIO LAN BE EF 03 06 00 8A D3 01 00 3B 20 11 00
OFF BE EF 03 06 00 DA DF 01 00 3B 20 00 00
Get BE EF 03 06 00 E9 DF 02 00 3B 20 00 00
AUDIO
SOURCE -
HDMI 1
Set
AUDIO IN1 BE EF 03 06 00 2A DC 01 00 33 20 01 00
AUDIO IN2 BE EF 03 06 00 DA DC 01 00 33 20 02 00
AUDIO HDMI 1 BE EF 03 06 00 7A C4 01 00 33 20 20 00
OFF BE EF 03 06 00 BA DD 01 00 33 20 00 00
Get BE EF 03 06 00 89 DD 02 00 33 20 00 00
AUDIO
SOURCE -
HDMI 2
Set
AUDIO IN1 BE EF 03 06 00 C2 DE 01 00 3D 20 01 00
AUDIO IN2 BE EF 03 06 00 32 DE 01 00 3D 20 02 00
AUDIO HDMI 2 BE EF 03 06 00 02 C7 01 00 3D 20 21 00
OFF BE EF 03 06 00 52 DF 01 00 3D 20 00 00
Get BE EF 03 06 00 61 DF 02 00 3D 20 00 00
AUDIO
SOURCE -
HDBaseT
Set
AUDIO IN1 BE EF 03 06 00 9E EA 01 00 D4 20 01 00
AUDIO IN2 BE EF 03 06 00 6E EA 01 00 D4 20 02 00
AUDIO HDBaseT BE EF 03 06 00 0E F0 01 00 D4 20 24 00
OFF BE EF 03 06 00 0E EB 01 00 D4 20 00 00
Get BE EF 03 06 00 3D EB 02 00 D4 20 00 00
AUDIO
SOURCE -
VIDEO
Set
AUDIO IN1 BE EF 03 06 00 92 DD 01 00 31 20 01 00
AUDIO IN2 BE EF 03 06 00 62 DD 01 00 31 20 02 00
OFF BE EF 03 06 00 02 DC 01 00 31 20 00 00
Get BE EF 03 06 00 31 DC 02 00 31 20 00 00
LAN SOUND
ENABLE
Set Disable BE EF 03 06 00 BA F0 01 00 A3 20 00 00
Enable BE EF 03 06 00 2A F1 01 00 A3 20 01 00
Get BE EF 03 06 00 89 F0 02 00 A3 20 00 00

RS-232C Communication / Network command table (continued)
32
LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016)
Names Operation Type Header CRC Command Data
Action Type Setting code
LANGUAGE Set
ENGLISH BE EF 03 06 00 F7 D3 01 00 05 30 00 00
FRANÇAIS BE EF 03 06 00 67 D2 01 00 05 30 01 00
DEUTSCH BE EF 03 06 00 97 D2 01 00 05 30 02 00
ESPAÑOL BE EF 03 06 00 07 D3 01 00 05 30 03 00
ITALIANO BE EF 03 06 00 37 D1 01 00 05 30 04 00
NORSK BE EF 03 06 00 A7 D0 01 00 05 30 05 00
NEDERLANDS BE EF 03 06 00 57 D0 01 00 05 30 06 00
PORTUGUÊS BE EF 03 06 00 C7 D1 01 00 05 30 07 00
BE EF 03 06 00 37 D4 01 00 05 30 08 00
BE EF 03 06 00 A7 D5 01 00 05 30 09 00
BE EF 03 06 00 37 DE 01 00 05 30 10 00
BE EF 03 06 00 57 D5 01 00 05 30 0A 00
SVENSKA BE EF 03 06 00 C7 D4 01 00 05 30 0B 00
PУCCKИЙ BE EF 03 06 00 F7 D6 01 00 05 30 0C 00
SUOMI BE EF 03 06 00 67 D7 01 00 05 30 0D 00
POLSKI BE EF 03 06 00 97 D7 01 00 05 30 0E 00
TÜRKÇE BE EF 03 06 00 07 D6 01 00 05 30 0F 00
Get BE EF 03 06 00 C4 D3 02 00 05 30 00 00

RS-232C Communication / Network command table (continued)
33
LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016)
Names Operation Type Header CRC Command Data
Action Type Setting code
MENU
POSITION V
Get BE EF 03 06 00 40 D7 02 00 16 30 00 00
Increment BE EF 03 06 00 26 D7 04 00 16 30 00 00
Decrement BE EF 03 06 00 F7 D6 05 00 16 30 00 00
MENU
POSITION V
Reset
Execute BE EF 03 06 00 A8 C7 06 00 44 70 00 00
MENU
POSITION H
Get BE EF 03 06 00 04 D7 02 00 15 30 00 00
Increment BE EF 03 06 00 62 D7 04 00 15 30 00 00
Decrement BE EF 03 06 00 B3 D6 05 00 15 30 00 00
MENU
POSITION H
Reset
Execute BE EF 03 06 00 DC C6 06 00 43 70 00 00
BLANK
Set
My Screen BE EF 03 06 00 FB CA 01 00 00 30 20 00
ORIGINAL BE EF 03 06 00 FB E2 01 00 00 30 40 00
BLUE BE EF 03 06 00 CB D3 01 00 00 30 03 00
WHITE BE EF 03 06 00 6B D0 01 00 00 30 05 00
BLACK BE EF 03 06 00 9B D0 01 00 00 30 06 00
Get BE EF 03 06 00 08 D3 02 00 00 30 00 00
BLANK On/Off
Set OFF BE EF 03 06 00 FB D8 01 00 20 30 00 00
ON BE EF 03 06 00 6B D9 01 00 20 30 01 00
Get BE EF 03 06 00 C8 D8 02 00 20 30 00 00
AUTO BLANK
Set
BLUE BE EF 03 06 00 67 D1 01 00 0D 30 03 00
WHITE BE EF 03 06 00 C7 D2 01 00 0D 30 05 00
BLACK BE EF 03 06 00 37 D2 01 00 0D 30 06 00
Get BE EF 03 06 00 A4 D1 02 00 0D 30 00 00
START UP
Set
My Screen BE EF 03 06 00 CB CB 01 00 04 30 20 00
ORIGINAL BE EF 03 06 00 0B D2 01 00 04 30 00 00
OFF BE EF 03 06 00 9B D3 01 00 04 30 01 00
Get BE EF 03 06 00 38 D2 02 00 04 30 00 00
My Screen Lock
Set OFF BE EF 03 06 00 3B EF 01 00 C0 30 00 00
ON BE EF 03 06 00 AB EE 01 00 C0 30 01 00
Get BE EF 03 06 00 08 EF 02 00 C0 30 00 00
OSD MESSAGE
Set
OFF BE EF 03 06 00 8F D6 01 00 17 30 00 00
ON BE EF 03 06 00 1F D7 01 00 17 30 01 00
HIDE BE EF 03 06 00 EF D7 01 00 17 30 02 00
Get BE EF 03 06 00 BC D6 02 00 17 30 00 00
TEMPLATE Set
TEST PATTERN BE EF 03 06 00 43 D9 01 00 22 30 00 00
DOT-LINE 1 BE EF 03 06 00 D3 D8 01 00 22 30 01 00
DOT-LINE 2 BE EF 03 06 00 23 D8 01 00 22 30 02 00
DOT-LINE 3 BE EF 03 06 00 B3 D9 01 00 22 30 03 00
DOT-LINE 4 BE EF 03 06 00 83 DB 01 00 22 30 04 00
CIRCLE 1 BE EF 03 06 00 13 DA 01 00 22 30 05 00
CIRCLE 2 BE EF 03 06 00 E3 DA 01 00 22 30 06 00
MAP 1 BE EF 03 06 00 83 D4 01 00 22 30 10 00
MAP 2 BE EF 03 06 00 13 D5 01 00 22 30 11 00
STACK BE EF 03 06 00 83 C0 01 00 22 30 20 00
Get BE EF 03 06 00 70 D9 02 00 22 30 00 00

RS-232C Communication / Network command table (continued)
34
LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016)
Names Operation Type Header CRC Command Data
Action Type Setting code
TEMPLATE
On/Off
Set OFF BE EF 03 06 00 BF D8 01 00 23 30 00 00
ON BE EF 03 06 00 2F D9 01 00 23 30 01 00
Get BE EF 03 06 00 8C D8 02 00 23 30 00 00
Closed Caption
C.C. - DISPLAY
Set
OFF BE EF 03 06 00 01 00 00 37 00 00FA 62
ON BE EF 03 06 00 6A 63 01 00 00 37 01 00
AUTO BE EF 03 06 00 9A 63 01 00 00 37 02 00
Get BE EF 03 06 00 C9 62 02 00 00 37 00 00
Closed Caption
C.C. - MODE
Set CAPTIONS BE EF 03 06 00 06 63 01 00 01 37 00 00
TEXT BE EF 03 06 00 96 62 01 00 01 37 01 00
Get BE EF 03 06 00 35 63 02 00 01 37 00 00
Closed Caption
C.C. - CHANNEL
Set
1 BE EF 03 06 00 D2 62 01 00 02 37 01 00
2 BE EF 03 06 00 22 62 01 00 02 37 02 00
3 BE EF 03 06 00 B2 63 01 00 02 37 03 00
4 BE EF 03 06 00 82 61 01 00 02 37 04 00
Get BE EF 03 06 00 71 63 02 00 02 37 00 00
SOURCE SKIP -
COMPUTER IN
Set NORMAL BE EF 03 06 00 FE 78 01 00 20 22 00 00
SKIP BE EF 03 06 00 6E 79 01 00 20 22 01 00
Get BE EF 03 06 00 CD 78 02 00 20 22 00 00
SOURCE SKIP -
LAN
Set NORMAL BE EF 03 06 00 DA 7A 01 00 2B 22 00 00
SKIP BE EF 03 06 00 4A 7B 01 00 2B 22 01 00
Get BE EF 03 06 00 E9 7A 02 00 2B 22 00 00
SOURCE SKIP -
HDMI 1
Set NORMAL BE EF 03 06 00 BA 78 01 00 23 22 00 00
SKIP BE EF 03 06 00 2A 79 01 00 23 22 01 00
Get BE EF 03 06 00 89 78 02 00 23 22 00 00
SOURCE SKIP -
HDMI 2
Set NORMAL BE EF 03 06 00 52 7A 01 00 2D 22 00 00
SKIP BE EF 03 06 00 C2 7B 01 00 2D 22 01 00
Get BE EF 03 06 00 61 7A 02 00 2D 22 00 00
SOURCE SKIP -
HDBaseT
Set NORMAL BE EF 03 06 00 B6 EA 01 00 D6 20 00 00
SKIP BE EF 03 06 00 26 EB 01 00 D6 20 01 00
Get BE EF 03 06 00 85 EA 02 00 D6 20 00 00
SOURCE SKIP -
VIDEO
Set NORMAL BE EF 03 06 00 02 79 01 00 21 22 00 00
SKIP BE EF 03 06 00 92 78 01 00 21 22 01 00
Get BE EF 03 06 00 31 79 02 00 21 22 00 00
AUTO SEARCH Set OFF BE EF 03 06 00 B6 D6 01 00 16 20 00 00
ON BE EF 03 06 00 26 D7 01 00 16 20 01 00
Get BE EF 03 06 00 85 D6 02 00 16 20 00 00
DIRECT
POWER ON
Set OFF BE EF 03 06 00 3B 89 01 00 20 31 00 00
ON BE EF 03 06 00 AB 88 01 00 20 31 01 00
Get BE EF 03 06 00 08 89 02 00 20 31 00 00
AUTO POWER
OFF
Get BE EF 03 06 00 08 86 02 00 10 31 00 00
Increment BE EF 03 06 00 6E 86 04 00 10 31 00 00
Decrement BE EF 03 06 00 BF 87 05 00 10 31 00 00
SHUTTER
TIMER
Set
1h BE EF 03 06 00 27 92 01 00 06 24 01 00
3h BE EF 03 06 00 47 93 01 00 06 24 03 00
6h BE EF 03 06 00 17 90 01 00 06 24 06 00
Get BE EF 03 06 00 84 93 02 00 06 24 00 00

RS-232C Communication / Network command table (continued)
35
LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016)
Names Operation Type Header CRC Command Data
Action Type Setting code
LAMP HOURS
Lower Bytes Get BE EF 03 06 00 C2 FF 02 00 90 10 00 00
LAMP HOURS
Higher Bytes Get BE EF 03 06 00 2A FD 02 00 9E 10 00 00
LAMP HOURS
Reset Execute BE EF 03 06 00 58 DC 06 00 30 70 00 00
FILTER HOURS
Lower Bytes Get BE EF 03 06 00 C2 F0 02 00 A0 10 00 00
FILTER HOURS
Higher Bytes Get BE EF 03 06 00 D6 FC 02 00 9F 10 00 00
FILTER HOURS
Reset Execute BE EF 03 06 00 98 C6 06 00 40 70 00 00
MY BUTTON-1 Set
MY IMAGE BE EF 03 06 00 5A 3D 01 00 00 36 16 00
MESSENGER BE EF 03 06 00 AA 29 01 00 00 36 25 00
SHUTTER BE EF 03 06 00 5A 26 01 00 00 36 32 00
INFORMATION BE EF 03 06 00 01 00 00 36 10 00FA 3E
MY MEMORY BE EF 03 06 00 9A 3F 01 00 00 36 12 00
DYNAMIC IRIS BE EF 03 06 00 AA 3D 01 00 00 36 15 00
PICTURE MODE BE EF 03 06 00 0A 3E 01 00 00 36 13 00
FILTER RESET BE EF 03 06 00 3A 3C 01 00 00 36 14 00
TEMPLATE BE EF 03 06 00 CA 39 01 00 00 36 1B 00
MUTE BE EF 03 06 00 01 00 00 36 38 00FA 20
PbyP/PIP SWAP BE EF 03 06 00 5A 38 01 00 00 36 1A 00
PIP POSITION BE EF 03 06 00 3A 22 01 00 00 36 3C 00
BLANK BE EF 03 06 00 01 00 00 36 40 00FA 02
RESOLUTION BE EF 03 06 00 9A 3A 01 00 00 36 1E 00
ECO MODE BE EF 03 06 00 0A 25 01 00 00 36 37 00
eClarity BE EF 03 06 00 9A 21 01 00 00 36 3A 00
HDCR BE EF 03 06 00 5A 23 01 00 00 36 3E 00
Get BE EF 03 06 00 09 33 02 00 00 36 00 00
MY BUTTON-2 Set
MY IMAGE BE EF 03 06 00 A6 3C 01 00 01 36 16 00
MESSENGER BE EF 03 06 00 56 28 01 00 01 36 25 00
SHUTTER BE EF 03 06 00 A6 27 01 00 01 36 32 00
INFORMATION BE EF 03 06 00 06 3F 01 00 01 36 10 00
MY MEMORY BE EF 03 06 00 66 3E 01 00 01 36 12 00
DYNAMIC IRIS BE EF 03 06 00 56 3C 01 00 01 36 15 00
PICTURE MODE BE EF 03 06 00 F6 3F 01 00 01 36 13 00
FILTER RESET BE EF 03 06 00 C6 3D 01 00 01 36 14 00
TEMPLATE BE EF 03 06 00 36 38 01 00 01 36 1B 00
MUTE BE EF 03 06 00 06 21 01 00 01 36 38 00
PbyP/PIP SWAP BE EF 03 06 00 A6 39 01 00 01 36 1A 00
PIP POSITION BE EF 03 06 00 C6 23 01 00 01 36 3C 00
BLANK BE EF 03 06 00 06 03 01 00 01 36 40 00
RESOLUTION BE EF 03 06 00 66 3B 01 00 01 36 1E 00
ECO MODE BE EF 03 06 00 F6 24 01 00 01 36 37 00
eClarity BE EF 03 06 00 66 20 01 00 01 36 3A 00
HDCR BE EF 03 06 00 A6 22 01 00 01 36 3E 00
Get BE EF 03 06 00 F5 32 02 00 01 36 00 00

RS-232C Communication / Network command table (continued)
36
LW502/LWU502 User's Manual - Technical
020-001099-01 Rev. 1 (06-2016)
Names Operation Type Header CRC Command Data
Action Type Setting code
MY BUTTON-3 Set
MY IMAGE BE EF 03 06 00 E2 3C 01 00 02 36 16 00
MESSENGER BE EF 03 06 00 12 28 01 00 02 36 25 00
SHUTTER BE EF 03 06 00 E2 27 01 00 02 36 32 00
INFORMATION BE EF 03 06 00 42 3F 01 00 02 36 10 00
MY MEMORY BE EF 03 06 00 22 3E 01 00 02 36 12 00
DYNAMIC IRIS BE EF 03 06 00 12 3C 01 00 02 36 15 00
PICTURE MODE BE EF 03 06 00 B2 3F 01 00 02 36 13 00
FILTER RESET BE EF 03 06 00 82 3D 01 00 02 36 14 00
TEMPLATE BE EF 03 06 00 72 38 01 00 02 36 1B 00
MUTE BE EF 03 06 00 42 21 01 00 02 36 38 00
PbyP/PIP SWAP BE EF 03 06 00 E2 39 01 00 02 36 1A 00
PIP POSITION BE EF 03 06 00 82 23 01 00 02 36 3C 00
BLANK BE EF 03 06 00 42 03 01 00 02 36 40 00
RESOLUTION BE EF 03 06 00 22 3B 01 00 02 36 1E 00
ECO MODE BE EF 03 06 00 B2 24 01 00 02 36 37 00
eClarity BE EF 03 06 00 22 20 01 00 02 36 3A 00
HDCR BE EF 03 06 00 E2 22 01 00 02 36 3E 00
Get BE EF 03 06 00 B1 32 02 00 02 36 00 00
MY BUTTON-4 Set
MY IMAGE BE EF 03 06 00 1E 3D 01 00 03 36 16 00
MESSENGER BE EF 03 06 00 EE 29 01 00 03 36 25 00
SHUTTER BE EF 03 06 00 1E 26 01 00 03 36 32 00
INFORMATION BE EF 03 06 00 BE 3E 01 00 03 36 10 00
MY MEMORY BE EF 03 06 00 DE 3F 01 00 03 36 12 00
DYNAMIC IRIS BE EF 03 06 00 EE 3D 01 00 03 36 15 00
PICTURE MODE BE EF 03 06 00 4E 3E 01 00 03 36 13 00
FILTER RESET BE EF 03 06 00 7E 3C 01 00 03 36 14 00
TEMPLATE BE EF 03 06 00 8E 39 01 00 03 36 1B 00
MUTE BE EF 03 06 00 BE 20 01 00 03 36 38 00
PbyP/PIP SWAP BE EF 03 06 00 1E 38 01 00 03 36 1A 00
PIP POSITION BE EF 03 06 00 7E 22 01 00 03 36 3C 00
BLANK BE EF 03 06 00 BE 02 01 00 03 36 40 00
RESOLUTION BE EF 03 06 00 DE 3A 01 00 03 36 1E 00
ECO MODE BE EF 03 06 00 4E 25 01 00 03 36 37 00
eClarity BE EF 03 06 00 DE 21 01 00 03 36 3A 00
HDCR BE EF 03 06 00 1E 23 01 00 03 36 3E 00
Get BE EF 03 06 00 4D 33 02 00 03 36 00 00
Product specificaties
Merk: | Christie |
Categorie: | Beamer |
Model: | LWU502 |
Kleur van het product: | Wit |
Gewicht: | 7200 g |
Breedte: | 466 mm |
Diepte: | 338 mm |
Hoogte: | 138 mm |
Geluidsniveau: | 39 dB |
Gewicht verpakking: | 10300 g |
Breedte verpakking: | 560 mm |
Diepte verpakking: | 478 mm |
Hoogte verpakking: | 246 mm |
Aantal lampen: | 1 lampen |
Soort lamp: | UHB |
Stroombron: | AC |
Plaatsing: | Desktop |
Afstandsbediening: | IR |
Ethernet LAN: | Ja |
Ondersteunde video-modi: | 480i, 480p, 576i, 576p, 720p, 1080i, 1080p |
Meegeleverde kabels: | AC, VGA |
Typische contrastverhouding: | 10000:1 |
Zoomcapaciteit: | Ja |
Markt positionering: | Bedrijf |
Projector helderheid: | 5000 ANSI lumens |
Projectietechnologie: | 3LCD |
Projector native resolution: | WUXGA (1920x1200) |
Geschikt voor schermmaten: | - " |
Projectie-afstand objectief: | - m |
Frequentiebereik horizontaal: | 15 - 106 kHz |
Frequentiebereik verticaal: | 60 - 120 Hz |
Matrix grootte: | 0.67 " |
Aantal USB 2.0-poorten: | 1 |
VGA (D-Sub)poort(en): | 3 |
Aantal HDMI-poorten: | 3 |
Soort serieële aansluiting: | RS-232C |
Microfoon, line-in ingang: | Ja |
Audio-ingang (L, R): | 1 |
Composiet video-ingang: | 1 |
DVI-poort: | Nee |
Aantal Ethernet LAN (RJ-45)-poorten: | 1 |
Zoom type: | Handmatig |
Brandpuntbereik: | - mm |
Levensduur van de lichtbron: | 4000 uur |
Type lichtbron: | Lamp |
Stroomverbruik (in standby): | - W |
Hoofdtelefoonuitgangen: | 1 |
Zoomverhouding: | 1.7:1 |
Throw ratio: | 1.4-2.3:1 |
Formaat analoog signaal: | NTSC, NTSC 4.43, PAL, PAL L, PAL M, PAL N, SECAM |
Volledige HD: | Ja |
Lampvermogen: | 300 W |
Levensduur van de lichtbron (besparingsmodus): | 6000 uur |
Geluidsniveau (spaarzame modus): | 30 dB |
Warmtedissipatie: | 1502 BTU/h |
Afstandsbediening inbegrepen: | Ja |
HDBaseT-poort: | Ja |
AC-ingangsspanning: | 100 - 240 V |
AC-ingangsfrequentie: | 50 - 60 Hz |
Type product: | Projector met normale projectieafstand |
Heb je hulp nodig?
Als je hulp nodig hebt met Christie LWU502 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Beamer Christie

16 December 2024

16 December 2024

16 December 2024

16 December 2024

11 November 2024

11 November 2024

11 November 2024

11 November 2024

5 November 2024

5 November 2024
Handleiding Beamer
- Beamer Philips
- Beamer HP
- Beamer Sony
- Beamer Samsung
- Beamer Xiaomi
- Beamer Casio
- Beamer Panasonic
- Beamer Epson
- Beamer LG
- Beamer Asus
- Beamer Canon
- Beamer JVC
- Beamer Medion
- Beamer Toshiba
- Beamer Yamaha
- Beamer Acco
- Beamer Acer
- Beamer Aiptek
- Beamer Anker
- Beamer AOpen
- Beamer ASK Proxima
- Beamer Auna
- Beamer Barco
- Beamer Bauer
- Beamer BenQ
- Beamer Blaupunkt
- Beamer D-Link
- Beamer Dell
- Beamer Easymaxx
- Beamer Eiki
- Beamer Elmo
- Beamer Emtec
- Beamer GPX
- Beamer Hama
- Beamer Hisense
- Beamer Hitachi
- Beamer Ibm
- Beamer InFocus
- Beamer Ion
- Beamer Klarstein
- Beamer Kodak
- Beamer Kogan
- Beamer La Vague
- Beamer Leica
- Beamer Lenco
- Beamer Lenovo
- Beamer Livoo
- Beamer Marantz
- Beamer Maxell
- Beamer Mitsubishi
- Beamer Nebula
- Beamer Nec
- Beamer PLUS
- Beamer Polaroid
- Beamer Pyle
- Beamer RCA
- Beamer Reflecta
- Beamer Renkforce
- Beamer Ricoh
- Beamer Salora
- Beamer Sanyo
- Beamer Sharp
- Beamer Showtec
- Beamer Smart
- Beamer Smartwares
- Beamer Speaka
- Beamer Steinel
- Beamer Strong
- Beamer Technaxx
- Beamer Viewsonic
- Beamer Vivitek
- Beamer Vogels
- Beamer XGIMI
- Beamer ZTE
- Beamer Odys
- Beamer OK
- Beamer Oki
- Beamer Optoma
- Beamer Overmax
- Beamer 3M
- Beamer Krüger And Matz
- Beamer Naxa
- Beamer Steren
- Beamer Eurolite
- Beamer Prixton
- Beamer Planar
- Beamer Dukane
- Beamer Yaber
- Beamer Mimio
- Beamer Da-Lite
- Beamer Adj
- Beamer Dahua Technology
- Beamer Derksen
- Beamer Celly
- Beamer Promethean
- Beamer Stairville
- Beamer Laserworld
- Beamer Beghelli
- Beamer Cameo
- Beamer Tzumi
- Beamer EKO
- Beamer MicroVision
- Beamer Elite Screens
- Beamer Celexon
- Beamer Fun Generation
- Beamer Futurelight
- Beamer Varytec
- Beamer Ultimea
- Beamer Dracast
- Beamer Dream Vision
- Beamer Knoll
- Beamer DTS
- Beamer Touchjet
- Beamer Boxlight
- Beamer AAXA Technologies
- Beamer Miroir
- Beamer Vankyo
- Beamer AWOL Vision
- Beamer Smart Tech
- Beamer Atlantis Land
- Beamer KickAss
- Beamer Microtek
- Beamer VAVA
- Beamer Panamorph
- Beamer Mirabella Genio
Nieuwste handleidingen voor Beamer

4 Maart 2025

4 Maart 2025

25 Februari 2025

20 Februari 2025

20 Februari 2025

20 Februari 2025

10 Februari 2025

30 Januari 2025

30 Januari 2025

30 Januari 2025