Carrier HolidayAKC009 Handleiding

Carrier Airco HolidayAKC009

Lees hieronder de 📖 handleiding in het Nederlandse voor Carrier HolidayAKC009 (15 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 13 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/15
51AKB / 51 AKC
OWNER’S MANUAL
Contents
Page
Control panel .................................................... 1
Accessories supplied ....................................... 1
General information ......................................... 2
Correct use .................................................... 2/3
Preparing to use ............................................... 4
Cooling with dehumidification ......................... 5
Dehumidification ............................................... 6
Fan only ............................................................ 7
Cleaning ............................................................ 7
In case of .......................................................... 8
This manual applies to the
following models
51AKB 009
51AKB 012
51AKC 009
51AKC 012
Read this instruction manual
thoroughly before using
the air conditioner.
Control panel
Accessories supplied
1. OFF position
2. TURBO cooling
3. Mode selector
4. SILENT cooling
5. Dehumidification
6. Thermostat
7. Low fan speed
8. High fan speed
9. Alarm indicator light
10. Fan speed indicator lights
11. Cooling indicator light
12. Dehumidification indicator light
1. Mounting brackets for the outdoor unit
2. Screws, nuts and washers for fixing
the mounting brackets
3. Fastening strap with suction cup
4. Strap with spring-clips
GB - 1
ENGLISH
1
2
3
4
1
2
3
4
6
5
8
7
9 10 11 12 9
TURBO
SILENT
GB - 2
General information
Correct use
• Check that the power supply at the installation
site is 230 V (min. 198 V - max. 264 V).
• The unit installation must comply with all
applicable local and national regulations.
• It is recommended to install a circuit breaker
or a 16 A safety fuse upstream of the supply
switch.
• The appliance must always be earthed.
• If an extension lead is needed (up to 25 m)
make sure that the wire section is not less
than 1.5 mm2.
• Do not locate the air conditioner in laundry
under dripping water (e.g.: clothes hung up
to dry).
• IMPORTANT: Non-compliance with these
safety standards constitutes a fire hazard
in the event of a short-circuit.
• The manufacturer does not accept any
liability if the safety standards are not
observed.
• This unit complies with low-voltage (EEC/
73/23) and electro-magnetic compatibility
(EEC/89/336) directives.
• Performances referred to ISO 5151.2/T1:
indoor temperature: 27 C d.b. - 19 C w.b.° °
tutdoor temperature: 35 C d.b. - 24 C w.b.° °
• The unit is designed to operate within the
following temperature limits:
cooling with dehumidification:
indoor temp.: min. 21°C d.b. - 15 C w.b.°
max. 32 C d.b. - 23 C w.b.° °
outdoor temp.: min. 21 C - max. 46 C.° °
dehumidification: min. 18°C d.b. - 14°C w.b.
max. 27°C d.b.-21°C w.b.
• Inspect equipment for damage due to
improper transportation or handling: In case
of damage file an immediate claim with the
shipping company.
• Do not use damaged equipment. In case of
a malfunction turn the unit off, disconnect
the plug from the power socket and contact
a qualified service engineer.
• Use the unit only for factory approved
applications.
• This equipment contains coolant.
Maintenance of the refrigerant circuit must
only be carried out by qualified personnel.
• All of the manufacturing and packaging
materials used for your new appliance
are compatible with the environment
and can be recycled.
• Dispose of the packaging material in
accordance with local requirements.
• This equipment contains coolant that must
be disposed of in a proper manner. When
disposing of the unit after its operational life,
remove it carefully. The unit must then be
delivered to an appropriate disposal center
or to the original equipment dealer, for proper
environmentally friendly disposal.
IMPORTANT: for UK only
The wires in this mains lead are coloured in
accordance with the following code:
Green-and-Yellow : Earth
Blue : Neutral
Brown : Live
As the colours of the wires in the mains lead
of this appliance may not correspond with
the coloured markings identifying the
terminals in your plug, proceed as follows:
• The wire which is coloured green-and-
yellow must be connected to the terminal
in the plug which is marked with the letter
E or by the earth symbol or coloured green
or green-and-yellow.
• The wire which is coloured must beblue
connected to the terminal which is marked
with the letter or coloured black.N
• The wire which is coloured must bebrown
connected to the terminal which is marked
with the letter or coloured red.L
The outdoor unit may be hung on the back
of the indoor unit with the flexible tube
neatly coiled, but never kinked, to allow
air conditioner to be moved from room to
room. It is recommended to move the unit
holding the front panel as illustrated.
The air conditioner models 51AKB009 and 51 AKB012 consist
of two units connected by a flexible tube of 1.8 metre length.
Models 51AKC009 and 51AKC012 are provided with a flexible
tube of 3.6 metre length and quick coupling connections that
allow the units to be disconnected up to a maximum of six times
without impairing air conditioning performance.
This operation must always be carried out by qualified and
authorized personnel.
The elegant portable indoor
unit may be positioned
conveniently in the room to
be air conditioned.
IMPORTANT
At first start-up of the unit
proceed as follows:
• take out the water tank at the rear
of the air conditioner
• remove the adhesive tape strip
• replace the tank correctly in its
position
If the above procedure is not
followed, the unit will not operate
and indicate a fault.
The compact, light weight
outdoor unit is placed
outdoors.


Product specificaties

Merk: Carrier
Categorie: Airco
Model: HolidayAKC009

Heb je hulp nodig?

Als je hulp nodig hebt met Carrier HolidayAKC009 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco Carrier

Handleiding Airco

Nieuwste handleidingen voor Airco