Caliber C 12300 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Caliber C 12300 (19 pagina's) in de categorie Autospeaker. Deze handleiding was nuttig voor 18 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/19
Models:
C 12100
C 12150
C 12300
C 12400
C 12600
C 12800
C 121000
Manual
DC-AC
Converters
Convertermanual 31-03-2005 08:48 Pagina 1
Convertermanual 31-03-2005 08:48 Pagina 3
Installing
During Operation, when the power switch is on, if power on indicator is not lighted. Please
check the fuse in the converter. If the fuse is damaged; please replace the fuse for the same
value fuse.
Warning signal
Low battery pre-alarm: biiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii
Over load pre-alarm: biiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii
Caution
• When connected to any appliance, be sure to turn on converter first. And then turn on
the powerswitch of the appliance.
• If the total Watt of electrical appliances exceeds the output capacity of converter, or after
operating for a period of time and the temperature of the converter reaches 60ËšC, the con-
verter shall be reduced AC output by the protection circuit.
• Always place the converter in an environment which is:
- Well ventilated.
- Not exposed to direct sunlight or heat source.
- Out of reach from children.
- Away from water, moisture, oil or grease.
- Away from any flammable substance.
Troubleshooting
If the converter does not appear to be functioning properly, there are several reasons why
the converter may not be responding.
• Poor contact.
- Clean contacts parts thoroughly.
• Receptacle has no power.
- Check fuse, replace damaged fuse.
- Check receptacle wiring. Repair if necessary.
• Overload caused AC output reduce.
- Reduce the wattage of your load to lower than the maximum Watt.
• Thermal caused AC output reduce.
- Under heavy loads for extended periods of time, the AC converter will reduce output
to prevent damage to excess heat. If this happens, please proceed as below:
a) Switch off the powerswitch of the converter.
b) Decrease load of this machine i.e. disconnect some of the appliances or wait until this
converter becomes cool.
c) Switch on the powerswitch off the converter.
• Low-battery shutdown.
- Recharge your battery and resume operation.
GB
C 12100 Specifications
Input
voltage range: 10V~15V DC
Output
voltage (AC): 220V
waveform: Modify sinewave
frequency: 50Hz
Continue power: 100W
Peak power: 200W
Battery low shutdown: <10.5V ± 0.5V DC
Thermal Protect: >60˚C ± 5˚C
Fuse-rating: 15A x 1pcs
C 12150 Specifications
Input
voltage range: 10V~15V DC
Output
voltage (AC): 220V
waveform: Modify sinewave
frequency: 50Hz
Continue power: 150W
Peak power: 300W
Battery low shutdown: <10.5V ± 0.5V DC
Thermal Protect: >60˚C ± 5˚C
Fuse-rating: 20A x 1pcs
C 12300 Specifications
Input
voltage range: 10V~15V DC
Output
voltage (AC): 220V
waveform: Modify sinewave
frequency: 50Hz
Continue power: 300W
Peak power: 600W
Battery low shutdown: <10.5V ± 0.5V DC
Thermal Protect: >60˚C ± 5˚C
Fuse-rating: 35A x 1pcs
C 12600 Specifications
Input
voltage range: 10V~15V DC
Output
voltage (AC): 220V
waveform: Modify sinewave
frequency: 50Hz
Continue power: 600W
Peak power: 1200W
Battery low shutdown: <10.5V ± 0.5V DC
Thermal Protect: >60˚C ± 5˚C
Fuse-rating: 30A x 3pcs
C 12800 Specifications
Input
voltage range: 10V~15V DC
Output
voltage (AC): 220V
waveform: Modify sinewave
frequency: 50Hz
Continue power: 800W
Peak power: 1600W
Battery low shutdown: <10.5V ± 0.5V DC
Thermal Protect: >60˚C ± 5˚C
Fuse-rating: 40A x 3pcs
C 12400 Specifications
Input
voltage range: 10V~15V DC
Output
voltage (AC): 220V
waveform: Modify sinewave
frequency: 50Hz
Continue power: 400W
Peak power: 800W
Battery low shutdown: <10.5V ± 0.5V DC
Thermal Protect: >60˚C ± 5˚C
Fuse-rating: 40A x 1pcs
C 121000 Specifications
Input
voltage range: 10V~15V DC
Output
voltage (AC): 220V
waveform: Modify sinewave
frequency: 50Hz
Continue power: 1000W
Peak power: 2000W
Battery low shutdown: <10.5V ± 0.5V DC
Thermal Protect: >60˚C ± 5˚C
Fuse-rating: 30A x 5pcs
Convertermanual 31-03-2005 08:48 Pagina 5


Product specificaties

Merk: Caliber
Categorie: Autospeaker
Model: C 12300

Heb je hulp nodig?

Als je hulp nodig hebt met Caliber C 12300 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Autospeaker Caliber

Handleiding Autospeaker

Nieuwste handleidingen voor Autospeaker