Installing
During Operation, when the power switch is on, if power on indicator is not lighted. Please
check the fuse in the converter. If the fuse is damaged; please replace the fuse for the same
value fuse.
Warning signal
Low battery pre-alarm: biiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii
Over load pre-alarm: biiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii
Caution
• When connected to any appliance, be sure to turn on converter first. And then turn on
the powerswitch of the appliance.
• If the total Watt of electrical appliances exceeds the output capacity of converter, or after
operating for a period of time and the temperature of the converter reaches 60ËšC, the con-
verter shall be reduced AC output by the protection circuit.
• Always place the converter in an environment which is:
- Well ventilated.
- Not exposed to direct sunlight or heat source.
- Out of reach from children.
- Away from water, moisture, oil or grease.
- Away from any flammable substance.
Troubleshooting
If the converter does not appear to be functioning properly, there are several reasons why
the converter may not be responding.
• Poor contact.
- Clean contacts parts thoroughly.
• Receptacle has no power.
- Check fuse, replace damaged fuse.
- Check receptacle wiring. Repair if necessary.
• Overload caused AC output reduce.
- Reduce the wattage of your load to lower than the maximum Watt.
• Thermal caused AC output reduce.
- Under heavy loads for extended periods of time, the AC converter will reduce output
to prevent damage to excess heat. If this happens, please proceed as below:
a) Switch off the powerswitch of the converter.
b) Decrease load of this machine i.e. disconnect some of the appliances or wait until this
converter becomes cool.
c) Switch on the powerswitch off the converter.
• Low-battery shutdown.
- Recharge your battery and resume operation.
GB
C 12100 Specifications
Input
voltage range: 10V~15V DC
Output
voltage (AC): 220V
waveform: Modify sinewave
frequency: 50Hz
Continue power: 100W
Peak power: 200W
Battery low shutdown: <10.5V ± 0.5V DC
Thermal Protect: >60˚C ± 5˚C
Fuse-rating: 15A x 1pcs
C 12150 Specifications
Input
voltage range: 10V~15V DC
Output
voltage (AC): 220V
waveform: Modify sinewave
frequency: 50Hz
Continue power: 150W
Peak power: 300W
Battery low shutdown: <10.5V ± 0.5V DC
Thermal Protect: >60˚C ± 5˚C
Fuse-rating: 20A x 1pcs
C 12300 Specifications
Input
voltage range: 10V~15V DC
Output
voltage (AC): 220V
waveform: Modify sinewave
frequency: 50Hz
Continue power: 300W
Peak power: 600W
Battery low shutdown: <10.5V ± 0.5V DC
Thermal Protect: >60˚C ± 5˚C
Fuse-rating: 35A x 1pcs
C 12600 Specifications
Input
voltage range: 10V~15V DC
Output
voltage (AC): 220V
waveform: Modify sinewave
frequency: 50Hz
Continue power: 600W
Peak power: 1200W
Battery low shutdown: <10.5V ± 0.5V DC
Thermal Protect: >60˚C ± 5˚C
Fuse-rating: 30A x 3pcs
C 12800 Specifications
Input
voltage range: 10V~15V DC
Output
voltage (AC): 220V
waveform: Modify sinewave
frequency: 50Hz
Continue power: 800W
Peak power: 1600W
Battery low shutdown: <10.5V ± 0.5V DC
Thermal Protect: >60˚C ± 5˚C
Fuse-rating: 40A x 3pcs
C 12400 Specifications
Input
voltage range: 10V~15V DC
Output
voltage (AC): 220V
waveform: Modify sinewave
frequency: 50Hz
Continue power: 400W
Peak power: 800W
Battery low shutdown: <10.5V ± 0.5V DC
Thermal Protect: >60˚C ± 5˚C
Fuse-rating: 40A x 1pcs
C 121000 Specifications
Input
voltage range: 10V~15V DC
Output
voltage (AC): 220V
waveform: Modify sinewave
frequency: 50Hz
Continue power: 1000W
Peak power: 2000W
Battery low shutdown: <10.5V ± 0.5V DC
Thermal Protect: >60˚C ± 5˚C
Fuse-rating: 30A x 5pcs
Convertermanual 31-03-2005 08:48 Pagina 5
Product specificaties
Merk: | Caliber |
Categorie: | Autospeaker |
Model: | C 121000 |
Heb je hulp nodig?
Als je hulp nodig hebt met Caliber C 121000 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Autospeaker Caliber
13 Juni 2023
11 Juni 2023
12 Mei 2023
6 Mei 2023
24 April 2023
18 April 2023
7 April 2023
7 April 2023
4 April 2023
31 Maart 2023
Handleiding Autospeaker
- Autospeaker Sony
- Autospeaker JVC
- Autospeaker JBL
- Autospeaker Kenwood
- Autospeaker Pioneer
- Autospeaker Alpine
- Autospeaker Auna
- Autospeaker Autotek
- Autospeaker Axton
- Autospeaker Blaupunkt
- Autospeaker Boss
- Autospeaker DLS
- Autospeaker Dnt
- Autospeaker Emphaser
- Autospeaker ESX
- Autospeaker Focal
- Autospeaker Fusion
- Autospeaker Hertz
- Autospeaker Hifonics
- Autospeaker Ices
- Autospeaker Infinity
- Autospeaker Kicker
- Autospeaker Lanzar
- Autospeaker Mac Audio
- Autospeaker Magnat
- Autospeaker Marquant
- Autospeaker Mr Handsfree
- Autospeaker Mtx Audio
- Autospeaker Pyle
- Autospeaker Renegade
- Autospeaker Renkforce
- Autospeaker Rockford Fosgate
- Autospeaker Soundstream
- Autospeaker JL Audio
- Autospeaker Clatronic
- Autospeaker Exibel
- Autospeaker Clarion
- Autospeaker Crunch
- Autospeaker Metra
- Autospeaker AudioControl
- Autospeaker Deaf Bonce
- Autospeaker Aquatic AV
- Autospeaker Planet Audio
- Autospeaker SoundMAX
- Autospeaker Memphis Audio
- Autospeaker Sinustec
- Autospeaker Sinus Live
- Autospeaker Audiotec Fischer
Nieuwste handleidingen voor Autospeaker
20 November 2024
20 November 2024
20 November 2024
20 November 2024
20 November 2024
20 November 2024
20 November 2024
20 November 2024
20 November 2024
20 November 2024