Bunn H3XA Element Handleiding

Bunn Water dispenser H3XA Element

Lees hieronder de šŸ“– handleiding in het Nederlandse voor Bunn H3XA Element (20 pagina's) in de categorie Water dispenser. Deze handleiding was nuttig voor 62 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/20
Supercedes:
10052.0000; 10010.0000; 10267.0000;
10420.0000; 10889.0000; 39338.0000;
39338.0001; 44306.0000; 46819.0000;
46819.0001
Hot Water Dispensers
Precision Water Systems
For Technical Service, contact Bunn-O-Matic Corporation at 1-800-286-6070.
46819.0002 B 09/20 Ā© 2014 Bunn-O-Matic Corporation
INSTALLATION & OPERATING GUIDE
Bunn-O-Matic Corporation
Post Office Box 3227, Springfield, Illinois 62708-3227
Phone (217) 529-6601 | Fax (217) 529-6644
www.bunn.com
2
Bunn-O-Matic Corp. (ā€œBUNNā€) warrants equipment manufactured by it as follows:
1) Airpots, thermal carafes, decanters, GPR servers, iced tea/coffee dispensers, MCR/MCP/MCA single cup brewers,
thermal servers and ThermoFreshĀ® servers (mechanical and digital) 1 year parts and 1 year labor.
2) All other equipment - 2 years parts and 1 year labor plus added warranties as speciļ¬ed below:
a) Electronic circuit and/or control boards - parts and labor for 3 years.
b) Compressors on refrigeration equipment - 5 years parts and 1 year labor.
c) Grinding burrs on coffee grinding equipment to grind coffee to meet original factory screen sieve analysis -
parts and labor for 4 years or 40,000 pounds of coffee, whichever comes ļ¬rst.
These warranty periods run from the date of installation BUNN warrants that the equipment manufactured by it will be
commercially free of defects in material and workmanship existing at the time of manufacture and appearing within the
applicable warranty period. This warranty does not apply to any equipment, component or part that was not manufactured
by BUNN or that, in BUNNā€™s judgment, has been affected by misuse, neglect, alteration, improper installation or operation,
improper maintenance or repair, non periodic cleaning and descaling, equipment failures related to poor water quality,
damage or casualty. In addition, the warranty does not apply to replacement of items subject to normal use including but
not limited to user replaceable parts such as seals and gaskets. This warranty is conditioned on the Buyer 1) giving BUNN
prompt notice of any claim to be made under this warranty by telephone at (217) 529-6601 or by writing to Post Ofļ¬ce Box
3227, Springļ¬eld, Illinois 62708-3227; 2) if requested by BUNN, shipping the defective equipment prepaid to an authorized
BUNN service location; and 3) receiving prior authorization from BUNN that the defective equipment is under warranty.
THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY, WRITTEN OR ORAL,
EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF EITHER MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE. The agents, dealers or employees of BUNN are not authorized to make
modiļ¬cations to this warranty or to make additional warranties that are binding on BUNN. Accordingly, statements by such
individuals, whether oral or written, do not constitute warranties and should not be relied upon.
If BUNN determines in its sole discretion that the equipment does not conform to the warranty, BUNN, at its exclusive
option while the equipment is under warranty, shall either 1) provide at no charge replacement parts and/or labor (during
the applicable parts and labor warranty periods speciļ¬ed above) to repair the defective components, provided that this
repair is done by a BUNN Authorized Service Representative; or 2) shall replace the equipment or refund the purchase
price for the equipment.
THE BUYERā€™S REMEDY AGAINST BUNN FOR THE BREACH OF ANY OBLIGATION ARISING OUT OF THE SALE OF THIS
EQUIPMENT, WHETHER DERIVED FROM WARRANTY OR OTHERWISE, SHALL BE LIMITED, AT BUNNā€™S SOLE OPTION
AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND.
In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost proļ¬ts, lost sales, loss of
use of equipment, claims of Buyerā€™s customers, cost of capital, cost of down time, cost of substitute equipment, facilities
or services, or any other special, incidental or consequential damages.
392, A Partner You Can Count On, Air Infusion, AutoPOD, AXIOM, BrewLOGIC, BrewMETER, Brew Better Not Bitter, Brew-
WISE, BrewWIZARD, BUNN Espress, BUNN Family Gourmet, BUNN Gourmet, BUNN Pour-O-Matic, BUNN, BUNN with
the stylized red line, BUNNlink, Bunn-OMatic, Bunn-O-Matic, BUNNserve, BUNNSERVE with the stylized wrench design,
Cool Froth, DBC, Dr. Brew stylized Dr. design, Dual, Easy Pour, EasyClear, EasyGard, FlavorGard, Gourmet Ice, Gourmet
Juice, High Intensity, iMIX, Infusion Series, Intellisteam, My CafƩ, Phase Brew, PowerLogic, Quality Beverage Equipment
Worldwide, Respect Earth, Respect Earth with the stylized leaf and coffee cherry design, Safety-Fresh, savemycoffee.com,
Scale-Pro, Silver Series, Single, Smart Funnel, Smart Hopper, SmartWAVE, Soft Heat, SplashGard, The Mark of Quality in
Beverage Equipment Worldwide, ThermoFresh, Titan, trifecta, TRIFECTA (stylized logo), Velocity Brew, Air Brew, Beverage
Bar Creator, Beverage Proļ¬t Calculator, Brew better, not bitter., Build-A-Drink, BUNNSource, Coffee At Its Best, Cyclonic
Heating System, Daypart, Digital Brewer Control, Element, Milk Texturing Fusion, Nothing Brews Like a BUNN, Picture
Prompted Cleaning, Pouring Proļ¬ts, Signature Series, Sure Tamp, Tea At Its Best, The Horizontal Red Line, Ultra are either
trademarks or registered trademarks of Bunn-O-Matic Corporation. The commercial trifectaĀ® brewer housing conļ¬guration
is a trademark of Bunn-O-Matic Corporation.
BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY
3
CONTENTS
INTRODUCTION
This equipment heats and dispenses water on
demand for beverages and cooking purposes. It
has a panel above the faucet that indicates the
status of the dispenser. This equipment is for
indoor use, either wall-mounted (H5E/X/PC) or
on a sturdy counter or shelf.
WARRANTY 2 ................................................................................................................................................
INTRODUCTION 3 ..........................................................................................................................................
CE & NORTH AMERICA REQUIREMENTS 4 ...................................................................................................
USER NOTICES 5 ...........................................................................................................................................
ELECTRICAL REQUIREMENTS 6 ....................................................................................................................
PLUMBING REQUIREMENTS 7 ......................................................................................................................
INITIAL SET-UP (H5E, H5X, H5-PC, H3/5 ELEMENTĀ®, H10X) 7 .....................................................................
INITIAL SET-UP H5M, HW2, OHW 8 ..............................................................................................................
OPERATING CONTROLS (H5-PC ONLY) 9 ......................................................................................................
ADJUST DISPENSE VOLUME (H5-PC ONLY) 9 ..............................................................................................
PROGRAMMING (H5E, H5XĀ®, H5-PC, H10X) 10 ............................................................................................
PROGRAMMING (H5 ELEMENTĀ®) 12 .............................................................................................................
PROGRAMMING (H3E ELEMENTĀ®) 15 ...........................................................................................................
DRAINING THE DISPENSER 20 .....................................................................................................................
CLEANING 20 .................................................................................................................................................
WALL MOUNT & SUPPORT 20 ......................................................................................................................
Brew water temperature is factory set at 200Ā° F (93.3Ā°C)
Areas of high altitude will require lowering this temperature
to prevent boiling. This chart should be used as a guide
when readjusting the brew water temperature.
Altitude
(Feet)
101.0
100.5
100.0
99.5
99.0
98.5
98.0
97.4
96.9
96.4
95.9
95.4
94.9
94.4
93.9
93.4
92.9
92.4
91.9
91.4
90.8
90.3
89.8
200
200
200
200
200
200
200
200
199
198
197
196
195
195
194
193
192
191
190
189
188
187
186
93.3
93.3
93.3
93.3
93.3
93.3
93.3
93.3
92.8
92.2
91.7
91.1
90.6
90.6
90.0
89.4
88.9
88.3
87.8
87.2
86.7
86.1
85.6
213.8
212.9
212.0
211.1
210.2
209.3
208.4
207.4
206.5
205.6
204.7
203.8
202.9
201.9
201.0
200.1
199.2
198.3
197.4
196.5
195.5
194.6
193.7
-1000
-500
0
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
5500
6000
6500
7000
7500
8000
8500
9000
9500
10000
Boiling point
of water
Ā°F Ā°C
Recommended
water temperature
Ā°F Ā°C


Product specificaties

Merk: Bunn
Categorie: Water dispenser
Model: H3XA Element

Heb je hulp nodig?

Als je hulp nodig hebt met Bunn H3XA Element stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Water dispenser Bunn

Handleiding Water dispenser

Nieuwste handleidingen voor Water dispenser