INSTALLATION MANUAL
Free Standing Ranges
RCS (Open/Sealed)
RNB
Platinum™
Precious Metals
750163
4
Please take a few moments now to fill in the information below for your future reference. In the event you require parts or
service, this information will be needed to ensure you receive the highest quality service we can provide.
DATE OF PURCHASE
DEALER’S NAME
DEALER’S ADDRESS
DATE OF INSTALLATION
INSTALLER’S NAME
INSTALLER’S ADDRESS
MODEL NUMBER
SERIAL NUMBER
14
GAS CONNECTIONS
This appliance must be installed by an approved installer or a gas technician
1. The installation of this appliance must conform with all applicable local codes. In the absence of local codes, the
installation must conform to the latest level of the National Fuel Gas Code, ANSI Z223.1/NFPA 54. In Canada, the
installation must be in accordance with the current CAN/CGA B149.1 and B149.2.
2. Maximum gas must not exceed 14 inches water column (wc) or 1/2 psi.
3. This appliance can be congured to work with either natural gas or LP gas. Verify that the appliance and the
incoming gas supply match. Check the rating plate.
4. Leak testing of the appliance shall be conducted according to the manufacturer s instructions.
5. Incoming gas pressure should be 1 in wc above appliance rating of 5 inches wc and 10 inches wc.
6. The gas supply line must be the same size or larger than the gas inlet of the appliance. Your appliance has either
a ½” NPT or ¾” NPT gas inlet connection. he supply line be ¼” NPT larger than the gas It is recommended that t
inlet of the appliance. If the gas supply line is not suciently sized, the operation of the appliance may be aected.
7. Sealant used on pipe joints must be resistant to LP gas.
8. An installer provided manual shut-o valve must be installed in the gas supply line ahead of the appliance. This
shut-o must be easily accessible in case of emergency.
9. All gas cooking equipment must have a pressure regulator on the incoming service line for safe and ecient
operation. This appliance is equipped with such a gas pressure regulator. Incoming gas pressure should be
checked with a manometer. The correct manifold pressure for natural gas is 5.0” wc. For LP gas the correct
manifold pressure is 10” wc.
10. ing manifold pressure. Incoming line pressure upstream of the appliance should be 1.0” wc greater than the operat
Service pressure may uctuate for a variety of reasons. Under no circumstances should the factory installed
regulator be removed or by-passed.
11. The factory installed pressure regulator will withstand an input pressure of ½ PSI (12” wc). If the incoming pressure
exceeds the maximum rating, a step-down regulator is required.
12. The appliance and its individual shut-o valve must be disconnected from the gas supply line during any pressure
testing in excess of ½ PSI [3.5 kPa].
13. The appliance must be disconnected from the gas supply by closing its individual shut-off during any pressure
testing less than ½ PSI [3.5 kPa].
14. Check to see that all installer supplied pipes and fittings are clear of debris, threading chips or other foreign particles
before connecting the appliance to the supply line. Such particles will clog orices and/or valves when pressure is
applied. Service to clean such clogs is not covered by your warranty.
15. The incoming gas supply is brought from the inlet pipe. This is the only connection required via the
installer-supplied shut-o valve.
16. If the appliance is to be installed with flexible couplings and/or a “quick disconnect” the installer must use a
commercially approved AGA Design Certified exible connector at least ½” NPT that complies with ANSI Z21.41.
In Canada, the connector must comply with CAN 16.10-88 and the “quick disconnect” device must comply with CAN
16.19M-79 and installed with a strain relief device.
17. Before putting the appliance into service test all gas connections for leaks. When pressure testing systems do not
exceed ½ psi or else damage will occur to the regulator. To test, use a soapy water solution. DO NOT USE AN
OPEN FLAME TO CHECK FOR LEAKS. Such a procedure is dangerous, and it may not detect all the small leaks
that a soapy solution will.
18. Air shutter adjustments are preset at the factory. These adjustments may need to be redone and/or fine tuned by
the installer. These adjustments are normal. They are the responsibility of the qualied installer and are not
covered by your warranty.
19. A gas type conversion performed in the eld may void your warranty. Contact your dealer for information regarding
the conversion from one type of gas supply to another.
20. Burner head locations are specic to the valves on the front of the unit. If burner heads are removed for cleaning or
other purposes, they must be re-installed in the same location they were removed from. Failure to do so may result
in a burner that will not light or possibly have a high ame.