Best PK2230 Handleiding

Best Afzuigkap PK2230

Lees hieronder de đź“– handleiding in het Nederlandse voor Best PK2230 (48 pagina's) in de categorie Afzuigkap. Deze handleiding was nuttig voor 77 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/48
PK22 AND PKEX22 SERIES
INSTALLATION INSTRUCTIONS
HB0123
INTENDED FOR DOMESTIC COOKING ONLY
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGES 11 TO 13.
READ AND SAVE THESE INSTRUCTIONS
BEST; Hartford, Wisconsin www.BestRangeHoods.com 800-558-1711
BEST; Drummondville, QC, Canada www.BestRangeHoods.com 866-737-7770
To register your product online or for additional information visit www.BestRangeHoods.com
SV20827 rev. 02
! !
2
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you
have questions, contact the manufacturer at the address or telephone
number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock service disconnecting means to prevent power from being
switched on accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning device, such
as a tag, to the service panel.
3. Installation work and electrical wiring must be done by qualified
personnel in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
backdrafting. Follow the heating equipment manufacturer’s guidelines
and safety standards such as those published by the National Fire
Protection Association (NFPA) and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE) and the local
code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any solid-state speed control device.
8. To reduce the risk of fire, use only metal ductwork.
9. This unit must be grounded.
10. When applicable local regulations comprise more restrictive installation
and/or certification requirements, the aforementioned requirements
prevail on those of this document and the installer agrees to conform
to these at his own expenses.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers cause
smoking and greasy spillovers that may ignite. Heat oils slowly on low
or medium settings.
b) Always turn power pack ON when cooking at high heat or when
flambeing food (i.e.: CrĂŞpes Suzette, Cherries Jubilee, Peppercorn
Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed to
accumulate on fan, filters or in exhaust ducts.
d) Use proper pan size. Always use cookware appropriate for the size of
the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE
THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet or metal tray,
then turn off the burner. BE CAREFUL TO PREVENT BURNS. IF THE
FLAMES DO NOT GO OUT IMMEDIATELY, EVACUATE AND CALL
THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels — This
could cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A. You own a Class ABC extinguisher and you know how to operate it.
The fire is small and contained in the area where it started.B.
The fire department has been called.C.
You can fight the fire with your back to an exit.D.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust hazardous or
explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power unit.
4. Your power pack motor has a thermal overload which will automatically
shut off the motor if it becomes overheated. The motor will restart
when it cools down. If the motor continues to shut off and restart, have
the power pack serviced.
5. The minimum power pack distance above cooktop must not be less
than 24”. A maximum of 30” above cooktop is recommended for best
capture of cooking impurities.
6. Two installers are recommended because of the large size and weight
of this unit.
7. To reduce the risk of fire and to properly exhaust air, be sure to duct air
outside — Do not exhaust air into spaces within walls or ceiling or into
attics, crawl space or garage.
8. This product is equipped with a thermostat which may start blower
automatically. To reduce the risk of injury and to prevent power from
being switched on accidentally, switch power off at service panel and
lock or tag service panel.
9. Because of the high exhausting capacity of this unit, you should make
sure enough air is entering the house to replace exhausted air by
opening a window close to or in the kitchen.
10. To reduce the risk of fire and electrical shock, the Best models PK22
series should only be installed with their own built-in blowers, and the
Best models PKEX22 Series must only be installed with Best external
blower models EB6, EB9, EB12 or EB15; or Best in-line blowers
models ILB3, ILB6, ILB9, ILB11. Other blowers cannot be substituted.
11. PKEX22 models used with ILB3, ILB6 or EB6 blower, must be installed
over ranges rated 60,000 Btu/hr. maximum.
12. Please read specification label on product for further information and
requirements.
13. This power pack is equipped with a RF receiver (optional remote
control sold separately). Changes or modifications not expressly
approved by the party responsible for compliance could void the
user’s authority to operate this product. The remote control has been
tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules and the Canadian ICES-003.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. The remote control
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or
more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected
WARNING
!
CAUTION
3
HL0192
+
-
f
¤
- PK22 POWER PACK SYSTEM -
M 437ODEL
(HIGH CAPACITY ROOF CAP)
MODEL 441
(10’’ ROUND WALL CAP)
M 418 ODEL
(10” R OUND
ADJUSTABLE ELBOW )
M 410 ODEL
(10” R OUND DUCT
— 2 )FT. SECTIONS
AL3036, AL3042, AL3948,
AL3954, AL4554 OR AL4560
CUSTOM HOOD LINER OPTIONAL ( )
M 421ODEL
(10” R OUND VERTICAL IN LINE DAMPER -
SUPPLIED WITH INTERNAL BLOWER POWER PAC K)
10” ROUND ADAPTER
( SUPPLIED WITH INTERNAL
BLOWER POWER PACK)
D (1200 )UAL BLOWER CFM
ALP36, ALP42, ALP48,
ALP54 OR ALP60
A MBIENT LIGHT PANEL OPTIONAL ( )
ACR1 REMOTE CONTROL
( )OPTIONAL
PK22 POWER PACK


Product specificaties

Merk: Best
Categorie: Afzuigkap
Model: PK2230

Heb je hulp nodig?

Als je hulp nodig hebt met Best PK2230 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Afzuigkap Best

Handleiding Afzuigkap

Nieuwste handleidingen voor Afzuigkap