Best PIK33 Handleiding

Best Afzuigkap PIK33

Lees hieronder de đź“– handleiding in het Nederlandse voor Best PIK33 (48 pagina's) in de categorie Afzuigkap. Deze handleiding was nuttig voor 31 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/48
MODELS PIK33 AND PIK45
INTENDED FOR DOMESTIC COOKING ONLY
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGES 11, 12 AND 13.
BEST BY BROAN P.O. Box 140, Hartford, WI 53027
V05862 rev E
HB0030
INSTALLATION INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
!
!
WARNING WARNING
- 2 -
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer at the address or telephone number
listed in the warranty.
2. Before servicing or cleaning unit, switch power off
at service panel and lock service disconnecting
means to prevent power from being switched on
accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done
by qualified personnel in accordance with all
applicable codes and standards, including fire-rated
construction codes and standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of
fuel burning equipment to prevent backdrafting.
Follow the heating equipment manufacturer’s
guidelines and safety standards such as those
published by the National Fire Protection
Association (NFPA), and the American Society for
Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the
outdoors.
7. Do not use this unit with any solid-state speed
control device other than WCPI optional wall
mounted control.
8. To reduce the risk of fire, use only metal ductwork.
9. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP
GREASE FIRE:
a) Never leave surface units unattended at high
settings. Boilovers cause smoking and greasy
spillovers that may ignite. Heat oils slowly on low or
medium settings.
b) Always turn hood ON when cooking at high heat or
when cooking flaming foods.
c) Clean ventilating fans frequently. Grease should
not be allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware
appropriate for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS
IN THE EVENT OF A RANGE TOP GREASE
FIRE, OBSERVE THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid,
cookie sheet or metal tray, then turn off the
burner. BE CAREFUL TO PREVENT BURNS. IF
THE FLAMES DO NOT GO OUT IMMEDIATELY,
EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN – You may
be burned.
3. DO NOT USE WATER, including wet dishcloths
or towels – This could cause a violent steam
explosion.
4. Use an extinguisher ONLY if:
A. You own a Class ABC extinguisher and
you know how to operate it.
B. The fire is small and contained in the area
where it started.
C. The fire department has been called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by
NFPA.
CAUTION
1. For general ventilating use only. Do not use to
exhaust hazardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or
unbalanced impellers, keep drywall spray,
construction dust, etc. off power unit.
3. Your insert motor has a thermal overload which will
automatically shut off the motor if it becomes
overheated. The motor will restart when it cools
down. If the motor continues to shut off and restart,
have the insert serviced.
4. The minimum hood distance above cooktop must
not be less than 24”. A maximum of 30” above
cooktop is highly recommended for best capture of
cooking impurities.
5. Two installers are recommended because of the
large size and weight of this unit.
6. To reduce the risk of fire and to properly exhaust
air, be sure to duct air outside – Do not exhaust air
into spaces within walls or ceiling or into attics,
crawl space or garage.
7. This product is equipped with a thermostat which
may start blower automatically. To reduce the risk
of injury and to prevent power from being switched
on accidentally, switch power off at service panel
and lock or tag service panel.
8. Because of the high exhausting capacity of this
unit, you should make sure enough air is entering
the house to replace exhausted air by opening a
window close to or in the kitchen.
9. To reduce the risk of fire and electrical shock, the
Best models PIK33 and PIK45 must be installed
with blower models P5, P8, EB6, EB9, EB12 or
EB15 only. Other blowers cannot be substituted.
(Blowers sold separately).
10. Use with approved cord-connection kit only.
11. Please read specification label on product for
further information and requirements.
!
!
HL004
1
- 3 -
RMP Series Backsplash
(Stainless Steel wall
covering with warming
shelves. Optional)
L3336, L3342, L4548, L4560,
L3336S, L3342S, L4548S or L4560S
Custom Hood Liner (optional)
Model 418
10” Rd
adjustable elbow
(optional)
Model 415
7” Rd adjustable
elbow (optional)
8” Rd
adjustable elbow
(optional)
Model 412
transition
(3 1/4” x 10” to 7”)
Adapter and damper
3 1/4’’ x 10’’
(supplied with P5
and P8 blowers)
Adapter and damper
3 1/4’’ x 14’’
(supplied with P8 blower)
Model P5
single-blower
(500 cfm)
PIK33 OR PIK45
INSERT
PIK33 AND PIK45
INSERT SYSTEM
Model EB6 (600 cfm)
or EB9 (900 cfm)
exterior blower
Model EB12 (1200 cfm)
or EB15 (1500 cfm)
exterior blower
Flow deviator
(supplied with P5 and P8 blowers)
Model 647
(7” Rd wall cap) Model 634 or 644
(roof cap) Model 643
(8” Rd wall cap)
Model 421
(10” Rd. vert.
in-line damper)
8” Rd
standard
duct
Model 407
(7” Rd x
24’’ section)
7” Rd metal
flexible duct
(optional)
8” Rd metal
flexible duct
(optional)
Model 413
transition
(3 1/4” x
10” to 8”)
Model 459 transition
(3 1/4” x 14” to 8”)
Model 410
(10” Rd duct
- 2ft. sections)
10” Rd metal
flexible duct
(optional)
Exterior blower rough-in kit
(included with EB6, EB9,
EB12 and EB15 blowers
Model P8
dual-blower (900 cfm)
NOTE: The dual blower P8 can be
installed either with 7’’ round
or 8’’ round ductwork.
For optimal air and quiet sound
performance, use 8’’round ductwork.
Rough-in kit
(supplied with P5 and P8 blowers)
ALP30, ALP36,
ALP42, ALP48 or ALP60
Ambient light panel (optional)
WCPI
Wall control
(Optional)


Product specificaties

Merk: Best
Categorie: Afzuigkap
Model: PIK33

Heb je hulp nodig?

Als je hulp nodig hebt met Best PIK33 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Afzuigkap Best

Handleiding Afzuigkap

Nieuwste handleidingen voor Afzuigkap

Miele

Miele DA 6520 D Handleiding

21 November 2024
Miele

Miele DA 420-4 Handleiding

21 November 2024
Miele

Miele DA 2660 Handleiding

21 November 2024
XO

XO R230W Handleiding

21 November 2024
Ilve

Ilve AGK90 Handleiding

20 November 2024
Ilve

Ilve AGQ90 Handleiding

20 November 2024
Ilve

Ilve AGQ60 Handleiding

20 November 2024
Ilve

Ilve AGQ120 Handleiding

20 November 2024
Ilve

Ilve AGK120 Handleiding

20 November 2024