Best Ispira ICB3I36SBN Handleiding

Best Afzuigkap Ispira ICB3I36SBN

Lees hieronder de 📖 handleiding in het Nederlandse voor Best Ispira ICB3I36SBN (48 pagina's) in de categorie Afzuigkap. Deze handleiding was nuttig voor 21 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/48
ICB3I SERIES
HB0117
INSTALLATION INSTRUCTIONS
INTENDED FOR DOMESTIC COOKING ONLY
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGES 12 TO 14.
READ AND SAVE THESE INSTRUCTIONS
BEST; Hartford, Wisconsin www.BestRangeHoods.com 800-558-1711
BEST; Drummondville, QC, Canada www.BestRangeHoods.ca 866-737-7770
23866 rev. 03
! !
2
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
qualified personnel in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturers guidelines and safety standards such as
those published by the National Fire Protection Association
(NFPA) and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE) and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented outdoors.
7. Do not use this unit with any additional solid-state speed
control device.
8. To reduce the risk of fire, use only metal ductwork.
9. This unit must be grounded.
10. All tempered glass can experience spontaneous breakage. If
broken, tempered glass falls out of its opening in interlocking
clumps. Tempered glass can, on occasion, break into large
shards rather than the classic tiny piece pattern.
11. When applicable, local regulations comprise more
restrictive installation and/or certification requirements,
the aforementioned requirements prevail on those of this
document and the installer agrees to conform to these at his
own expense.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee,
Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan, filters or in exhaust ducts.
d) Use proper pan size. Always use cookware appropriate for the
size of the surface element.
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Your hood motor has a thermal overload which will automatically
shut off the motor if it overheats. The motor will restart when it
cools down. If the motor continues to shut off and restart, have
the hood serviced.
5. The hood distance above cooktop must not be less than 30”.
A maximum of 36” above cooktop is highly recommended for
best capture of cooking impurities.
6. Two installers are recommended because of the large size and
weight of this unit.
7. To reduce the risk of fire and to properly exhaust air, be sure to
duct air outside — Do not exhaust air into spaces within walls
or ceiling or into attics, crawl space or garage.
8. Because of the high exhausting capacity of this unit, you
should make sure enough air is entering the house. Open a
window close to or in the kitchen.
9. To reduce the risk of fire and electrical shock, the Best ICB3I
Series models should only be installed with their own built-in
blower.
10. Please read specification label on product for further
information and requirements.
11. This hood is equipped with an RF receiver. See next page for
related warning.
WARNING
!
CAUTION
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE
THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY,
EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels
This could cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A. You own a Class ABC extinguisher and you know how to
operate it.
The fire is small and contained in the area where it started.B.
The fire department has been called.C.
You can fight the fire with your back to an exit.D.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
WARNING
!
3
WARNING
!
!
!
!!
This hood is equipped with a RF receiver (optional remote control sold separately). Changes or modifications
not expressly approved by the party responsible for compliance could void the users authority to operate this
product. The remote control has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules and the Canadian ICES-003. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. The remote control generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference
by one or more of the following measures:
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
TABLE OF CONTENTS
1. INSTALL DUCTWORK ................................................................................................................................................................................... 3
2. PREPARE INSTALLATION ............................................................................................................................................................................... 4
3. MEASURE INSTALLATION .............................................................................................................................................................................. 4
4. INSTALL MOUNTING BRACKET ........................................................................................................................................................................ 5
5. ASSEMBLE ANGLE BRACKETS ........................................................................................................................................................................ 6
6. REMOVE HYBRID FILTERS ............................................................................................................................................................................. 7
7. INSTALL GLASS PANELS SBN MODEL ONLY ( ) ...................................................................................................................................................... 7
8. PREPARE HOOD ALL MODELS ( ) .................................................................................................................................................................. 8-9
9. INSTALL HOOD ...................................................................................................................................................................................... 9-10
10. CONNECT WIRING .....................................................................................................................................................................................11
11. REINSTALL HYBRID FILTERS .........................................................................................................................................................................11
12. LED LIGHTING .........................................................................................................................................................................................12
13. CARE .....................................................................................................................................................................................................12
14. OPERATION ........................................................................................................................................................................................ 13-14
15. WIRING DIAGRAM ......................................................................................................................................................................................14
16. SERVICE PARTS ........................................................................................................................................................................................15
17. WARRANTY .............................................................................................................................................................................................16
1. INSTALL DUCTWORK
Plan where and how the ductwork will be installed.
A straight, short duct run will allow the hood to perform most efficiently.
Install proper-sized ductwork, elbows and roof cap. Connect metal ductwork to cap and
work back towards the hood location. Use 2” metal foil duct tape to seal the joints.
Run 3-wire power supply cable to installation location.
We recommend to install the hood at a minimum distance of 30” above cooking
surface. A maximum of 36” above cooktop is highly recommended for best capture
of cooking impurities.
8” R DOUND UCT
R COOF AP
HOOD
HH0152A
DECORATIVE
FLUE
8” ROUND
ADAPTER/DAMPER
30” 36” TO ABOVE
COOKING SURFACE
C 8 9 *EILING HEIGHT FEET FEET 10 FEET
MINIMUM DISTANCE RECOMMENDED ABOVE
COOKTOP
30 . 30 . 30 .IN IN IN
MAXIMUM RECOMMENDED HEIGHT IN IN IN 34 . 36 . 36 .
* 10-ft. ceilings require 10-ft flue extension, part no. AEICB3SB (sold separately).
Distances over 36” are at the installer and users discretion.


Product specificaties

Merk: Best
Categorie: Afzuigkap
Model: Ispira ICB3I36SBN

Heb je hulp nodig?

Als je hulp nodig hebt met Best Ispira ICB3I36SBN stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Afzuigkap Best

Handleiding Afzuigkap

Nieuwste handleidingen voor Afzuigkap