Installation, Service and User Instructions
(French version page 10)
DIMENSIONS: 36 1/2 1/4’’ (925 mm)(W) x 21 ’’ (540 mm)(D)
Models B3H0..Q7X(2 or 5)D Type ‘A’
Models B3K0..U7X(2 or 5)D Type ‘B’
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR’S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
OBSERVE ALL GOVERNING CODES AND ORDINANCES.
WARNING: If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or death.
Do not store or use gasoline or other flammable vapors and liquid in the vicinity of
this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electrical switch.
- Do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone. Follow
the gas supplier’s instructions.
- If you cannot reach your gas suppliers, call the fire department.
Installation and service must be performed by a qualified installer, service agency
or the gas supplier.
Read this instruction booklet before installing and using the appliance.
The manufacturer will not be responsible for any damage to property or to persons caused by
incorrect installation or improper use of the appliance.
The manufacturer reserves the right to make changes to its products when considered necessary and useful,
without affecting the essential safety and operating characteristics.
This appliance has been designed for non-professional, domestic use only.
Cod. 310498
Built-in gas hotplates
BERTAZZONI
2
INDEX:
Installation Instructions……………………………………..………………………..pag.2
Inserting the hotplate……………………………………………..…………………..pag.3
Requirements……………………………………..…………………………….…..pag.3
Attaching the hotplate……………………………………..………………………….pag.4
Gas connection……………………………………..…………………………………pag.4
Electrical connection……………………………………..……………………….…..pag.5
Wiring diagrams……………………………………..…………………………….…..pag.5
Room ventilation………………………………….…………………………………pag.5
Location and venting…………………………………….…………………………….pag.5
Replacement of nozzles……………………………………..………………………..pag.5
Regulation of burners……………………………………………...………………….pag.6
Descriptions…………………………………………………………………………….pag.6
Service & maintenance instructions……………………………..…………………..pag.6
Greasing the valves……………………………………………..…………………….pag.7
User instructions……………………………………………..………………………..pag.7
Using burners……………………………………………………..……………………pag.7
Cleaning the appliance……………………………………………..…………………pag.8
Figures………………………………………………...…………..……………………pag.19
Installation instructions
This appliance shall only be installed by an authorized person. This appliance shall be installed in
accordance with the manufacturers installation instructions, IMPORTANT: this appliance must be
installed in accordance with the norms in force of the country concerned.
The installation of this appliance must conform to local codes and ordinances. In the absence of
local codes, Installations must conforms to American National Standards, National Fuel Gas Code
ANSI Z223.1 – latest edition** or B149.1.
If local codes permit, a flexible metal appliance connection with the new AGA or CGA certified
design, max. 5 feet (1,5 m) long, ½” I.D. recommended for connecting this cooktop to the gas supply
line. Do not bend or damage the flexible connector when moving the cooktop. The pressure regulator
has ½” female pipe thread. You will need to determine the fitting required, depending on the size of
your gas supply line, the flexible metal connector and the shutoff valve.
The appliance, when installed, must be electrically grounded in accordance with local codes or, in
the absence of local codes, with the National Electrical Code, ANSI/NFPA 70.
The appliance and its individual shutoff valve must be disconnected from the gas supply piping
system any pressure testing of that system at test pressure in excess of ½ psi (3,5 kPa).
The appliance must be isolated from the gas supply piping system by closing its individual manual
shutoff valve during any pressure testing of the gas supply piping system at test pressures equal
to or less than ½ psi (3.5 kPa).
For use with a pressure regulator. The regulator supplied must be used with this appliance.
The gas appliance pressure regulator must be set for the gas with which the appliance is used.
This appliance can be used with Natural Gas and LP Gas. It is shipped from the factory adjusted for
use with Natural Gas: CONVERSION FIXED ORIFICES ARE LOCATEDIN THE LITERATURE PACK
SUPPLIED WITH THE UNIT.
Injectors kit for the change of type of gas are contained inside the package jointly with the hob
installation kit and Instruction booklet.
The maximum inlet gas supply pressure incoming to the gas appliance pressure regulator is 20’’
water column (5 kPa) .
3
The minimum gas supply pressure for checking the regulator setting shall be at least 1“ w.c. (249 Pa)
above the inlet specified manifold pressure to the appliance (this operating pressure is 4” w.c.
(1.00 kPa) for Natural Gas and 11” w.c. (2.75 kPa) for LP Gas).
ATTENTION: A manual valve shall be installed in an accessible location in the gas line external to the
appliance for the purpose of turning on or shutting off gas to the appliance
WARNING: Do not use aerosol sprays in the vicinity of this appliance while it is in operation
Inserting the hotplate
After having removed the various loose parts from the internal and external packing, make sure that the
hotplate in not damaged and is suitable for the specific gas usage. The gas type label is on the underside of
the hotplate base.
In case of doubt, do not use the appliance and contact skilled personnel.
Keep all the packing parts (polystyrene foam, cardboard, staples, etc.) away from children.
Consider the critical dimensions of the appliance, before making an opening in the top surface of the bench
top. (relative measurements as per Fig 1- 2).
Requirements
1. Overhead clearances (Minimum values)
The minimum overhead clearances shall be in accordance with the minimum values indicated in the table
n.1 and are shown and in the fig. 1- 2
Range hoods and exhaust fans shall be installed in accordance with the manufacturer’s instructions.
However, in no case shall the clearance between the top of the highest burner of the cooking appliance and
the range hood be less than 25 1/2”( 650mm).
Any other downward facing combustible surface less than 600mm above the top of the highest burner shall
be protected for the full width and depth of the cooking surface area.
However, in no case shall this clearance to any surface be less than 173/4”(450mm.)
Maximum depth for the overheads cabinet is 13” (330mm)
2. Side clearances (Minimum values)
The different side clearances shall be in accordance with the minimum values indicated in the table n.1 and
are shawn and in the fig. 1- 2
The cooking surface area is defined as that part of the appliance where cooking normally takes place and
does not include those parts of the appliance containing control knobs.
Table n.1
Hobs models Type A
Type B Hobs
models
Type A
Type B
Min. Clearances inches (mm) Min. Clearances inches (mm)
L1 20 1/2 (520) L10 35 10/16 (905)
L2 1 9/16“ (40) L11 36“ (915)
L3 2 5/32“ (55) W 36 1/2“ (925)
L4 18” (457) D 21 1/4“ (540)
L5 24” (610) B1 (*) 1 9/16“ (40)
L6 13” (330) B2 (*) 6“ (152)
L7 36 1/2“ (925) B3 (*) 1 3/4” (45)
L8 1 9/16“ (40)type A
3/4 (20) type B
B4 (*) 6“ (152)
L9 6 3/8 (162)
(*) Note:
-B1 is the min. clearance between the front edge of the appliance and the front edge of the cabinet.
-B2 and B4 are the min. clearance between the left/right side edge of the appliance and the side wall (if
present).
-B3 is the min. clearance between the back edge of the appliance and the back wall.


Product specificaties

Merk: Bertazzoni
Categorie: Fornuis
Model: DB36 6 00 X
Apparaatplaatsing: Ingebouwd
Soort bediening: Draaiknop
Kleur van het product: Roestvrijstaal
Ingebouwd display: Nee
Breedte: 925 mm
Diepte: 540 mm
Hoogte: 40 mm
Soort materiaal (bovenkant): Roestvrijstaal
Vermogen brander/kookzone 2: 5000 W
Vermogen brander/kookzone 3: 1750 W
Vermogen brander/kookzone 1: 1750 W
Aantal branders/kookzones: 6 zone(s)
Type kookplaat: Gaskookplaat
Electronische ontsteking: Ja
Type brander/kookzone 1: Regulier
Type brander/kookzone 2: Extra groot
Type brander/kookzone 3: Regulier
Aantal gaspitten: 6 zone(s)
Controle positie: Rechtsboven
Installatie compartiment breedte: 905 mm
Installatie compartiment diepte: 520 mm
Installatie compartiment hoogte: 35 mm
Stroom: 1 A
Materiaal pannensteun: Gietijzer
Veiligheidsklep: Ja
Certificering: CSA
Type brander/kookzone 4: Regulier
Vermogen brander/kookzone 4: 1750 W
Voedingsbron brander/kookzone 1: Gas
Voedingsbron brander/kookzone 2: Gas
Voedingsbron brander/kookzone 3: Gas
Voedingsbron brander/kookzone 4: Gas
Wokbrander: 5000 W
Wokbrander positie: Links voor
Positie brander/kookzone 1: Links achter
Positie brander/kookzone 2: Links voor
Positie brander/kookzone 3: Midden achter
Positie brander/kookzone 4: Midden voor
Kookzone 1 vorm: Rond
Kookzone 2 vorm: Rond
Kookzone 3 vorm: Rond
Kookzone 4 vorm: Rond
Voedingsbron brander/kookzone 5: Gas
Voedingsbron brander/kookzone 6: Gas
Type brander/kookzone 5: Groot
Type brander/kookzone 6: Sudderen
Positie brander/kookzone 5: Rechts achter
Vermogen brander/kookzone 5: 3000 W