Installation, Service and User Instructions
Built-in gas cooktops
BERTAZZONI
DIMENSIONS: 36’’ (915 mm)(W) x 253/16’’ (640 mm)(D)
Models CB36500X [C3W0..U7X (2 or 5)A]
Models CB36600X [C3Y0..U7X(2 or 5)A]
IMPORTANT - PLEASE READ AND FOLLOW
-Before beginning installation, please read these instructions completely and carefully.
-Do not remove permanently affixed labels, wa may void the warranty. -Please observe alrnings, or plates from the product. This l local
and national codes and ordinances.
-Please ensure that this product is properly grounded.
-The installer should leave these instructions with the consumer who should retain for local inspector's use and for
future reference.
-The electrical plug should always be accessible.
Installation must conform with local codes or in the absence of codes, the National Fuel Gas Code ANSIZ223.1-latest edition. Electrical
installation must be in accordance with the National Electrical Code, ANIS/NFPA70
- latest edition and/or local codes. IN CANADA:
Installation must be in accordance with the current CAN/CGA-B149.1 National Gas Installation Code or CAN/CGA-B
149.2, Propane
Installation Code and/or local codes. Electrical installation must be in accordance with the current CSA C22.1 Canadian Electrical
Codes Part 1 and/or local codes.
Installation of any gas-fired equipment should be made by a licensed plumber. A manual gas shut-off valve must be installed in the gas
supply line ahead of the oven in the gas flow for safety and ease of service.
In Massachusetts: All gas products must be installed by a "Massachusetts" licensed plumber or gasfitter. A "T" handle type manual
gas valve must be installed in the gas supply line to this appliance.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR’S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
OBSERVE ALL GOVERNING CODES AND ORDINANCES.
WARNING: If the information in this manual is not followed exactly, a
fire or explosion may result causing property damage, personal injury
or death.
Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
- Do not light any appliance.
- Do not touch any electrical switch.
- Do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone. Follow
the gas supplier’s instructions.
- If you cannot reach your gas suppliers, call the fire department.
Installation and service must be performed by a qualified installer,
service agency or the gas supplier.
310496
2
WARNING
Read this instruction booklet before installing and using the appliance.
The manufacturer will not be responsible for any damage to property or to persons caused by incorrect
installation or improper use of the appliance.
The manufacturer reserves the right to make changes to its products when considered necessary and useful, without
affecting the essential safety and operating characteristics.
This appliance has been designed for non-professional, domestic use only.
Warning: do not use this appliance to heat a room.
Installation instructions
This appliance shall only be installed by an authorized person. This appliance shall be installed in accordance
with the manufacturer’s installation instructions, IMPORTANT: this appliance must be installed in accordance
with the norms & standards of the country where it will be installed.
The installation of this appliance must conform to local codes and ordinances. In the absence of local codes,
Installations must conforms to American National Standards, National Fuel Gas Code ANSI Z223.1 – latest
edition** or B149.1.
If local codes permit, a flexible metal appliance connection with the new AGA or CGA certified design, max. 5
feet (1,5 m) long, ½” I.D. is recommended for connecting this appliance to the gas supply line. Do not bend or
damage the flexible connector when moving the appliance. The pressure regulator has ½” female pipe thread.
The appropriate fitting must be determined based on the size of your gas supply line, the flexible metal
connector and the shutoff valve.
The appliance, when installed, must , in the absence be electrically grounded in accordance with local codes or
of local codes, with the National Electrical Code, ANSI/NFPA 70.
The appliance and its individual shutoff valve must be disconnected from the gas supply piping system any
pressure testing of that system at test pressure in excess of ½ psi (3,5 kPa).
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psi (3.5
kPa).
For use with a pressure regulator. The regulator supplied must be used with this appliance; it shall be properly
installed in order to be accessible when appliance is installed in its final location.
The gas appliance pressure regulator must be set for the gas with which the appliance is used.
This appliance can be used with Natural Gas and LP Gas. It is shipped from the factory adjusted for use with
Natural Gas: CONVERSION FIXED ORIFICES ARE LOCATED IN THE LITERATURE PACK SUPPLIED WITH THE
UNIT.
A gas nozzle kit for the change of type of gas are contained inside the package tigether with the gas
appliance installation kit and instruction booklet.
The maximum inlet gas supply pressure incoming to the gas appliance pressure regulator is 20’’ water column
(5 kPa) .
The minimum gas supply pressure for checking the regulator setting shall be at least 1“ w.c. (249 Pa) above the
inlet specified manifold pressure to the appliance (this operating pressure is 4” w.c. (1.00 kPa) for Natural Gas
and 11” w.c. (2.75 kPa) for LP Gas.
ATTENTION: A manual valve shall be installed in an accessible location in the gas line external to the appliance
for the purpose of turning on or shutting off gas to the appliance
WARNING: Do not use aerosol sprays in the vicinity of this appliance while it is in operation
Requirements
Room ventilation – Location and venting.
ATTENTION: An exhaust fan may be used with the appliance; in each case it shall be installed in conformity with
the national standards in force.
ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be installed in
conformity with the national standards in force.
3
INSTALLATION MANUAL
WORKTOP FRONTGUARD INSTALLATION INSTRUCTIONS
In order to increase the clearance between front edge of the worktop and the burners for your safety it is
recomended to install the worktop frontguard supplied with the appliance. For installation instructions follow
the instructions indicated in the following figures


Product specificaties

Merk: Bertazzoni
Categorie: Fornuis
Model: CB36 6 00 X
Apparaatplaatsing: Ingebouwd
Soort bediening: Draaiknop
Kleur van het product: Roestvrijstaal
Ingebouwd display: Nee
Breedte: 910 mm
Diepte: 640 mm
Hoogte: 165 mm
Soort materiaal (bovenkant): Roestvrijstaal
Vermogen brander/kookzone 2: 5000 W
Vermogen brander/kookzone 3: 1750 W
Vermogen brander/kookzone 1: 1750 W
Aantal branders/kookzones: 6 zone(s)
Type kookplaat: Gaskookplaat
Electronische ontsteking: Ja
Type brander/kookzone 1: Regulier
Type brander/kookzone 2: Extra groot
Type brander/kookzone 3: Regulier
Aantal gaspitten: 6 zone(s)
Installatie compartiment breedte: 914 mm
Installatie compartiment hoogte: 165 mm
Materiaal pannensteun: Gietijzer
Veiligheidsklep: Ja
Certificering: CSA
Type brander/kookzone 4: Regulier
Vermogen brander/kookzone 4: 1750 W
Voedingsbron brander/kookzone 1: Gas
Voedingsbron brander/kookzone 2: Gas
Voedingsbron brander/kookzone 3: Gas
Voedingsbron brander/kookzone 4: Gas
Wokbrander: Ja
Wokbrander positie: Links voor
Positie brander/kookzone 1: Links achter
Positie brander/kookzone 2: Links voor
Positie brander/kookzone 3: Midden achter
Positie brander/kookzone 4: Midden voor
Kookzone 1 vorm: Rond
Kookzone 2 vorm: Rond
Kookzone 3 vorm: Rond
Kookzone 4 vorm: Rond
Voedingsbron brander/kookzone 5: Gas
Voedingsbron brander/kookzone 6: Gas
Type brander/kookzone 5: Groot
Type brander/kookzone 6: Sudderen
Positie brander/kookzone 5: Rechts achter
Vermogen brander/kookzone 5: 3000 W
Positie brander/kookzone 6: Rechts voor
Vermogen brander/kookzone 6: 1000 W
Kookzone 5 vorm: Rond
Kookzone 6 vorm: Rond

Heb je hulp nodig?

Als je hulp nodig hebt met Bertazzoni CB36 6 00 X stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Fornuis Bertazzoni

Handleiding Fornuis

Nieuwste handleidingen voor Fornuis