BeamZ Panther 2R Handleiding
BeamZ
Effect machine
Panther 2R
Lees hieronder de š handleiding in het Nederlandse voor BeamZ Panther 2R (68 pagina's) in de categorie Effect machine. Deze handleiding was nuttig voor 20 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/68
Panther 2R Moving Head
Ref. nr.: 150.482
INSTRUCTION MANUAL
GEBRUIKSAANWIJZING
GEBRAUCHSANLEITUNG
MANUAL DE INSTRUCCIONES
MANUEL D'INSTRUCTIONS
V1.1
2
3
ENGLISH
Congratulations to the purchase of this Beamz light eļ¬ect. Please read this manual thoroughly prior to using the unit in order to
beneļ¬t fully from all features.
Read the manual prior to using the unit. Follow the instructions in order not to invalidate the warranty. Take all precautions to
avoid ļ¬re and/or electrical shock. Repairs must only be carried out by a qualiļ¬ed technician in order to avoid electrical shock.
Keep the manual for future reference.
- Prior to using the unit, please ask advice from a
specialist. When the unit is switched on for the ļ¬rst time,
some smell may occur. This is normal and will disappear
after a while.
- The unit contains voltage carrying parts. Therefore do
NOT open the housing.
- Do not place metal objects or pour liquids into the unit
This may cause electrical shock and malfunction.
- Do not place the unit near heat sources such as
radiators, etc. Do not place the unit on a vibrating
surface. Do not cover the ventilation holes.
- The unit is not suitable for continuous use.
- Be careful with the mains lead and do not damage it. A
faulty or damaged mains lead can cause electrical shock
and malfunction.
- When unplugging the unit from a mains outlet, always
pull the plug, never the lead.
- Do not plug or unplug the unit with wet hands.
- If the plug and/or the mains lead are damaged, they
need to be replaced by a qualiļ¬ed technician.
- If the unit is damaged to such an extent that internal
parts are visible, do NOT plug the unit into a mains outlet
and DO NOT switch the unit on. Contact your dealer. Do
NOT connect the unit to a rheostat or dimmer.
- To avoid ļ¬re and shock hazard, do not expose the unit to
rain and moisture.
- All repairs should be carried out by a qualiļ¬ed technician
only.
- Connect the unit to an earthed mains outlet (220-
240Vac/50Hz) protected by a 10-16A fuse.
- During a thunderstorm or if the unit will not be used for a
longer period of time, unplug it from the mains. The rule
is: Unplug it from the mains when not in use.
- If the unit has not been used for a longer period of time,
condensation may occur. Let the unit reach room
temperature before you switch it on. Never use the unit in
humid rooms or outdoors.
- During operation, the housing becomes very hot. Do not
touch it during operation and immediately after.
- To prevent accidents in companies, you must follow the
applicable guide lines and follow the instructions.
- Secure the unit with an extra safety chain if the unit is
ceiling mount. Use a truss system with clamps. Make
sure nobody stands in the mounting area. Mount the
eļ¬ect at least 50cm away from inļ¬ammable material and
leave at least 1 meter space on every side to ensure
suļ¬cient cooling.
- This unit contains high intensity . Do not look into the bulb
bulb to prevent damage to your eyes.
- Do not repeatedly switch the ļ¬xture on and oļ¬. This
shortens the life time.
- Keep the unit out of the reach of children. Do not leave
the unit unattended.
- Do not use cleaning sprays to clean switches. The
residues of these sprays cause deposits of dust and
grease. In case of malfunction, always seek advice from
a specialist.
- Only operate the unit with clean hands.
- Do not force the controls.
- If the unit has fallen, always have it checked by a
qualiļ¬ed technician before you switch the unit on again.
- Do not use chemicals to clean the unit. They damage the
varnish. Only clean the unit with a dry cloth.
- Keep away from electronic equipment that may cause
interference.
- Only use original spares for repairs, otherwise serious
damage and/or dangerous radiation may occur.
- Switch the unit oļ¬ prior to unplugging it from the mains
and/or other equipment. Unplug all leads and cables
prior to moving the unit.
- Make sure that the mains lead cannot be damaged when
people walk on it. Check the mains lead before every use
for damages and faults!
- The mains voltage is 220-240Vac/50Hz. Check if power
outlet match. If you travel, make sure that the mains
voltage of the country is suitable for this unit.
- Keep the original packing material so that you can
transport the unit in safe conditions
This mark attracts the attention of the user to high voltages that are present inside the housing and that are of suļ¬cient
magnitude to cause a shock hazard.
This mark attracts the attention of the user to important instructions that are contained in the manual and that he should
read and adhere to.
DO NOT LOOK DIRECTLY INTO THE LENS. This can damage your eyes. Persons who are subject to epileptic attacks
should be aware of the eļ¬ects that this light eļ¬ect may have on them.
The unit has been certiļ¬ed CE. It is prohibited to make any changes to the unit. They would invalidate the CE certiļ¬cate and
their guarantee!
NOTE: To make sure that the unit will function normally, it must be used in rooms with a temperature between 5Ā°C/ Ā°F 41 and
35 95Ā°C/ Ā°F.
Electric products must not be put into household waste. Please bring them to a recycling centre. Ask your local authorities or your
dealer about the way to proceed. The speciļ¬cations are typical. The actual values can slightly change from one unit to the other.
Speciļ¬cations can be changed without prior notice.
Product specificaties
Merk: | BeamZ |
Categorie: | Effect machine |
Model: | Panther 2R |
Kleur van het product: | Zwart |
Gewicht: | 12500 g |
Breedte: | 260 mm |
Diepte: | 345 mm |
Hoogte: | 410 mm |
Aantal lampen: | 1 lampen |
Vermogen lamp: | 132 W |
Stroombron: | AC |
Aan/uitschakelaar: | Ja |
Ingangsspanning: | 100 - 240 V |
Frequentie: | 50-60 Hz |
Stralingshoek: | 3 Ā° |
XLR in: | Ja |
XLR out: | 1 |
Stroomverbruik (typisch): | 260 W |
Baldiameter: | - " |
Aantal DMX-kanalen: | 15 kanalen |
Heb je hulp nodig?
Als je hulp nodig hebt met BeamZ Panther 2R stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Effect machine BeamZ
2 November 2024
29 Augustus 2024
25 Juli 2024
25 Juli 2024
25 Juli 2024
25 Juli 2024
24 Juni 2023
15 Juni 2023
10 Juni 2023
10 Juni 2023
Handleiding Effect machine
- Effect machine Behringer
- Effect machine Boss
- Effect machine HQ
- Effect machine HQ Power
- Effect machine Konig
- Effect machine Manta
- Effect machine Martin
- Effect machine Max
- Effect machine Midas
- Effect machine Monacor
- Effect machine Nedis
- Effect machine Pyle
- Effect machine Showtec
- Effect machine Velleman
- Effect machine Viking
- Effect machine Westinghouse
- Effect machine JB Systems
- Effect machine Monoprice
- Effect machine NGS
- Effect machine Steren
- Effect machine Eurolite
- Effect machine American DJ
- Effect machine Antari
- Effect machine Chauvet
- Effect machine QTX
- Effect machine Valcom
- Effect machine Karma
- Effect machine Adj
- Effect machine Elation
- Effect machine Valueline
- Effect machine Fredenstein
- Effect machine TC Electronic
- Effect machine Elysia
- Effect machine Stairville
- Effect machine Black Lion Audio
- Effect machine Laserworld
- Effect machine TCM FX
- Effect machine Drawmer
- Effect machine ColorKey
- Effect machine Evo-Lite
- Effect machine Blizzard
- Effect machine Hazebase
- Effect machine IGS Audio
- Effect machine Cameo
- Effect machine Sagitter
- Effect machine DJPower
- Effect machine Doepfer
- Effect machine Fun Generation
- Effect machine Lotronic
- Effect machine IMG Stage Line
- Effect machine Lexicon
- Effect machine Futurelight
- Effect machine The Confetti Maker
- Effect machine Eliminator Lighting
- Effect machine BoomTone DJ
- Effect machine Klark Teknik
- Effect machine Lab Gruppen
- Effect machine Audibax
- Effect machine Magmatic
- Effect machine Technical Pro
- Effect machine Rosco
- Effect machine Showven
Nieuwste handleidingen voor Effect machine
4 December 2024
30 November 2024
20 November 2024
19 November 2024
16 November 2024
15 November 2024
7 November 2024
7 November 2024
7 November 2024
7 November 2024