Audibax Thunder 250 Handleiding

Audibax Verlichting Thunder 250

Lees hieronder de 📖 handleiding in het Nederlandse voor Audibax Thunder 250 (12 pagina's) in de categorie Verlichting. Deze handleiding was nuttig voor 18 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/12
Thunder 250 RGB
Please read the manual before using the product
USER´S
MANUAL
11
Thunder 250 RGB
NOTES:
USER´S
MANUAL
Thunder 250 RGB
1 10
1. Menu function
After powering on, press the menu button, and the menu function table will appear
in sequence; the UP or DOWN button to modify the function parameters, the ENTER
button to save the current functions and parameters (with power-off memory after
saving).
Menu function table:
2. Master-slave control
Two or more identical lamps are connected with DMX three-core signal line, the
lamps are set to any address code A001~A512, any one is set as the master, and the
other lamps are the slaves, all the slaves’ displays do not flicker; use the master to
fade, Pulse change, jump change, voice control, and self-propelled effects, all slaves
will synchronize gradual change, pulse change, jump, voice control, and
self-propelled effects.
Special attention:
1. Only one host can be set for a group of lamps. If there is more than one host, all
lamps will flash randomly and out of sync.
2. All lamps and lanterns must be the master and slave when the DMX512 console is
turned off.
3. Factory setting
When any address code is A001~A512, press the menu button for 3 seconds to enter
the factory setting. Factory settings are mainly the functions of each output power of
the lamp, fan setting mode, setting temperature protection point, and sending
parameters. Any mode in the factory setting can be excited by pressing the menu
button for 3 seconds.
A001
A512
Modify the address code (A001~A512) UP or DOWN, and save with the ENTER
key. The default is A001.
CH0
3
CH24
Switch between CH03, CH09, CH24 three channels UP or DOWN, ENTER key to
save, default CH09.
FF00
FF99
Gradient, modify the gradual speed UP or DOWN (FF00~FF99), confirm to save,
the default is FF10.
EE00
EE99
Pulse change, modify the pulse change speed UP or DOWN (EE00~EE99),
confirm to save, default EE10.
P000
P241
There are 242 kinds of built-in effects (P000~P241), switch the built-in effects ,
save by the ENTER key, and jump to P000 by default.
S000
S255
Modify the operating speed of the built-in effect (S000~S255) UP or DOWN, and
save with the ENTER key. The default is S010.
Soud
Soud
Sound control mod
R255
R000
Modify the brightness of the red lamp bead UP or DOWN (R000~R255), and save
with the ENTER key. The default is R255.
G25
5
G000
Modify the brightness of the green lamp bead UP or DOWN (G000~G255),
confirm to save, and the default is G255.
B255
B000
Modify the brightness of the blue lamp bead UP or DOWN (B000~B255), confirm
to save, and the default is B255.
T000
Display temperature. For example, T045 means that the current lamp
temperature is 45℃; if 10K thermistor is not installed, T000 is displayed.
USER´S
MANUAL
Thunder 250 RGB
9 2
6. Technical Parameters:
Voltage: AC100~240V 50/60HZ
Power: 240W
Lamp beads: 960pcs 5050 tri-color LED lamp beads
Control mode: DMX512, self-propelled, master-slave, voice control, with RDM
function.
Channel: CH03, CH09, CH24
Dimming: 32bit 0~100% linear dimming
Features: 8-segment horse racing + dyeing + flashing
Working temperature: -30 degrees to 50 degrees
Strobe frequency: 1~30HZ
Appearance: metal, black
Connection mode: DMX512 input and output / power input and output.
IP rating: IP20
Factory setting table:
CH09 Description:
4. DMX512 Control
After power on, all lamps and lanterns address codes are set up, connect all
lamps and lanterns in parallel to the DMX512 console with a three-core signal
line, the address codes will stop flashing, indicating that the DMX512 console
signal has been sent to the lamps, and use DMX512 console control according
to the description of each channel Related functions.
CH03 Description:
R
255 R032
Modify the red lamp bead current (R032-R255) up or down, confirm to save, and th
default is R240.
G
255 G032
Modify the green lamp bead current (G032-G255) up or down, and save it with the
confirm key. The default is G240.
B
255
B032
Modify the blue lamp bead current (B032-B255) up or down, confirm to save, and
the default is B240.
FAN0
FAN1
Fan setting: FAN0 lamp bead lights up to start the fan, FAN1 reaches the se
temperature protection point to start the fan, confirm to save.
T
040 T105
Set the temperature protection point, modify the parameter up or down
(40 ~105 ), press the confirm key to save, the default is T060. ℃ ℃
S
end Send
Send the factory setting parameters of this machine up or down to all other lamp
c
onnected in parallel with the three-core signal line; confirm the sendin
g
p
arameters and press the menu button for 3 seconds
Exit, deny the parameter and press the confirm key to cancel sending.
CH
NO.
Rang
Function & Instruction
1
000-255
Red lamp bead linear dimming
2
000-255
Green lamp bead linear dimming
3
000-255
Blue lamp bead linear dimming
CH
NO.
Rang
Function & Instruction
1
000-255
Total dimming
2
000-255 Red lamp bead linear dimming
3
000-255
Green lamp bead linear dimming
4
000-255
Blue lamp bead linear dimming
5
000-255
Strobe
6
000-255
Mode (see: VI. Mode Effect 1)
7
000-255
Mode (see: VI. Mode Effect 2)
8
000-255
Mode (see: VI. Mode Effect 3)
9
000-255
Speed


Product specificaties

Merk: Audibax
Categorie: Verlichting
Model: Thunder 250

Heb je hulp nodig?

Als je hulp nodig hebt met Audibax Thunder 250 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Verlichting Audibax

Handleiding Verlichting

Nieuwste handleidingen voor Verlichting