Argoclima TWIN 14A Handleiding

Argoclima Airco TWIN 14A

Lees hieronder de đź“– handleiding in het Nederlandse voor Argoclima TWIN 14A (16 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 27 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/16
37.4256.018.0 01/2012
Room air conditioner with remote condenser
Condizionatore d’ambiente con condensatore remoto
Climatiseur avec condenseur a air exterieur •
Klimagerät mit außenkondensator
Acondicionador de ambiente con condensador a distancia
Ar Condicionado com condensador remoto
K
K
K
K
Kl
l
l
l
li
i
i
i
im
m
m
m
ma
a
a
a
at
t
t
t
ti
i
i
i
is
s
s
s
st
t
t
t
ti
i
i
i
ik
k
k
k
ko
o
o
o
o
k
k
k
k
kl
l
l
l
le
e
e
e
ei
i
i
i
is
s
s
s
st
t
t
t
tw
w
w
w
wn
n
n
n
n
c
c
c
c
cw
w
w
w
wr
r
r
r
rw
w
w
w
wn
n
n
n
n
m
m
m
m
me
e
e
e
e
s
s
s
s
su
u
u
u
um
m
m
m
mp
p
p
p
pu
u
u
u
uk
k
k
k
kn
n
n
n
nw
w
w
w
wt
t
t
t
th
h
h
h
h
EG
I
F
D
E
P
COOL / DRY / FAN
COOL / DRY / HEAT / FAN GR
OPERATING INSTRUCTIONS â—Ź ISTRUZIONI D'USO
NOTICE D’UTILISATION ●BEDIENUNGSANLEITUNG
INSTRUCCIONES DE USO ●INSTRUCÇÕES DE FUNCIONAMENTO
O
O
O
O
OD
D
D
D
DH
H
H
H
HL
L
L
L
LI
I
I
I
IE
E
E
E
ES
S
S
S
S
C
C
C
C
CR
R
R
R
RH
H
H
H
HS
S
S
S
SE
E
E
E
EW
W
W
W
WS
S
S
S
S
COOL / DRY / FAN
MOVABLE AIR CONDITIONER
This air conditioner is equipped with cooling, drying and fan functions , cooling, drying, heating and fan
functions . Details on these functions are provided here following; refer on these descriptions
when using the air conditioner.
PRODUCT IDENTIFICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
MONITOR PANEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
INSTALLATION LOCATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
ELECTRICAL REQUIREMENTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
SAFETY INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
IMPORTANT ADVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
AIR CONDITIONER INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
USING THE REMOTE CONTROL UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
• How to install batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
• Temperature sensor selector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
• Operation with the remote control unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
REMOTE CONTROL UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
HOW TO SET THE PRESENT TIME. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
COOLING - HEATING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
AUTOMATIC OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
DEHUMIDIFYING (DRY) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
FAN ONLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
ADJUSTING THE FAN SPEED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
SLEEP MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
SETTING THE TIMER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
SETTING 1 HR TIMER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
ADJUSTING THE AIR FLOW DIRECTION . . . . . . . . . . . . . . . . . . . . . . . . . 10
OPERATION WITHOUT THE REMOTE CONTROL UNIT . . . . . . . . . . . . . . 10
CARE AND CLEANING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
ACCESSORIES (SUPPLIED ON REQUEST). . . . . . . . . . . . . . . . . . . . . . . . 12
TIPS FOR ENERGY SAVING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
TROUBLESHOOTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
ELECTRIC WIRING DIAGRAMS’ SYMBOLS . . . . . . . . . . . . . . . . . . . . . . . . 14
CONTENTS
NOTE
PRODUCT INFORMATION
If you have problems or questions concerning your Air
Conditioner, you will need the following information. Model
and serial numbers are on the nameplate on the bottom of
the air conditioner.
Model No. ..........................................................................
Serial No............................................................................
Date of purchase ...............................................................
Dealer’s address ...............................................................
Phone number ....................................
ALERT SYMBOLS
The following symbols used in this manual, alert you to
potentially dangerous conditions to users, service personnel
or the appliance:
This symbol refers to a hazard or unsafe practice which
can result in severe personal injury or death.
This symbol refers to a hazard or unsafe practice which
can result in personal injury or product or property damage.
WARNING
CAUTION
EG
COOL /DRY/FAN
COOL /DRY/HEAT/FAN
COOLING
OUTDOOR TEMPERATURE 46°C D.B.
ROOM TEMPERATURE 32°C D.B./23°C W.B.
OUTDOOR TEMPERATURE 19°C D.B.
ROOM TEMPERATURE 19°C D.B./14°C W.B.
OPERATING LIMITS
HEATING
OUTDOOR TEMPERATURE 24°C D.B./18°C W.B.
ROOM TEMPERATURE 27°C D.B.
OUTDOOR TEMPERATURE -8°C D.B./-9°C W.B.
MAXIMUM CONDITIONS
MINIMUM CONDITIONS
MAXIMUM CONDITIONS
MINIMUM CONDITIONS
DECLARATION OF CONFORMITY
This product is marked as it
satisfies Directives:
– Low voltage no. 2006/95/CE.
– Electromagnetic compatibility no.
2004/108/CE, 92/31 EEC and 93/68
EEC.
This declaration will become void in case
of misuse and/or non observance though
partial of manufacturer's installation
and/or operating instructions.
INFORMATION FOR
CORRECT DISPOSAL OF
THE PRODUCT IN
ACCORDANCE WITH THE
EUROPEAN DIRECTIVE
2002/96/EC
At the end of its working life this
equipment must not be disposed
of as an household waste.
It must be taken to special local
community waste collection centres
or to a dealer providing this service.
Disposing of an electrical and
electronic equipment and its
batteries separately avoids
possible negative effects on the
environment and human health
deriving from an inappropriate
disposal and enables its
components to be recovered and
recycled to obtain significant
savings in energy and resources.
In order to underline the duty to
dispose of this equipment and
batteries separately, the product is
marked with a crossed-out dustbin.
01. Infrared rays remote control unit
02. Monitor panel
03. Supply air deflector
, 4. Return air grille
, 5. Outdoor unit
06. Flexible tube
07. Air filter
08. Electric cable with plug
09. Service tube for condensate evacuation
10. Outdoor unit basket or support
11. Quick coupling cover
12. Transportation handle (both sides)
13. Transportation wheels
14. Outdoor unit hanger
MONITOR PANEL
1. TIMER lamp: This lamp lights up when the system is
being controlled by the timer.
2. OPERATION lamp: This lamp lights up during operation.It
blinks once to announce that the remote control signal
has been received and stored.
This lamp flashes and the air conditioner simultaneously
stops during exceeding condensate drainage or because
of malfunctioning of the condensate drainage system.
EG
The OFF position does not disconnect the power. Use the
main power switch to turn off power completely.
WARNING
WATER-LEVEL ALARM
3
5. Operation button (without remote control): Push the
button to walk through the OFF, COOL and HEAT
operation modes.
PRODUCT IDENTIFICATION
10
2
7
11
5
6
1
8
3
4
9
13
4
3
7
5
12
2
6
11 14
8
1
9
1
5
24
3 1
5
24
3 1 23 4
5
3. STANDBY lamp: this lamp lights up when the air
conditioner is connected to the power and ready to receive
the remote control command.
4. Receiver : receives signals transmitted from the remote
control.
NOTE
The blinking of OPERATION, TIMER and STANDBY lamps,
indicates that the operating mode selected ( ) is not
compatible with the unit. If this happen the air conditioner
does not operate until the correct mode is selected.
10


Product specificaties

Merk: Argoclima
Categorie: Airco
Model: TWIN 14A
Energie-efficiëntieklasse: A
Jaarlijks energieverbruik: 625 kWu
Soort: Splitssysteem
Geluidsniveau (lage snelheid): 39 dB
Geluidsniveau (hoge snelheid: 40 dB
Geluidsniveau (medium snelheid): 39 dB
Air conditioner functies: Cooling, Dehumidifying
Extern geluidsniveau: 41 dB
Luchtstroom: 460 mÂł/uur
Ontvochtiging capaciteit: 1.6 L/u
Koelcapaciteit (max): 13670 BTU/h
Koel capaciteit in watt (max): 4010 W
Koeling energie efficientie: 3.21
Indoor unit type: Staande
Indoor eenheid dimensies (BxDxH): 470 x 310 x 800 mm
Indoor eenheid gewicht: 41000 g
Outdoor eenheid dimensies (BxDxH): 525 x 250 x 509 mm
Outdoor eenheid gewicht: 10500 g
Indoor units hoeveelheid: 1
Outdoor units hoeveelheid: 1
Slanglengte (max): - m
Energieverbruik (koelen) (max): 1250 W

Heb je hulp nodig?

Als je hulp nodig hebt met Argoclima TWIN 14A stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco Argoclima

Handleiding Airco

Nieuwste handleidingen voor Airco