Argoclima Madison Handleiding

Argoclima Airco Madison

Lees hieronder de 📖 handleiding in het Nederlandse voor Argoclima Madison (19 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 79 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/19
V 01/22 20
PORTABLE AIR CONDITIONER (LOCAL)
MADISON
OPERATING INSTRUCTIONS
Read the instructions carefully before operating the appliance or carrying out maintenance work.
Observe all the safety instructions; failure to observe the instructions may lead to accidents and/or
damage. Store these instructions in a safe place for future reference.
EN
V 01/22 21
The Refrigerant R290
ï‚· To realize the function of the air conditioner unit, a special refrigerant circulates in the
system. The refrigerant is the fluoride R290 = 3 GWP (Global warming potential). This
refrigerant is flammable and inodorous. It can lead to explosions under certain conditions,
however the flammability of this refrigerant is very low and it can be ignited only by fire.
ï‚· Compared to other common refrigerants, R290 is a non-polluting refrigerant with no harm
to the ozonosphere and a no effect upon the greenhouse effect. R290 has very good
thermodynamic features which lead to a really high energy efficiency. The units therefore
need less filling.
Warning:
Do not try to accelerate the defrosting process or to clean the appliance in different ways other
than those recommended by the manufacturer. Should repair be necessary, contact your
nearest authorized Service Centre. Any repairs carried out by unqualified personnel may be
dangerous. The appliance has to be stored in a room that doesn’t have any continuously
operating ignition sources. (for example: open flames, an operating gas appliance or an
operating electric heater.) Do not pierce or burn.
Appliance has to be installed, used and stored in a room with a floor area larger than 12 m 2.
For repairs, strictly follow manufacturer’s instructions only for appliances filled with R290
flammable gas. Be aware that refrigerants do not have any odour.
Appliance is filled with flammable gas R290.
Before installing and using the appliance, read the
owner manual.
Before installing the appliance, read the installation
manual.
Any repairs you need, contact the nearest authorized
Service Centre and strictly follow manufacturer’s
Service Manual.
V 01/22 22
GENERAL OPERATING AND SAFETY INSTRUCTIONS
ï‚· This appliance is a local air conditioner designed for domestic use.
ï‚· Only use this air-conditioner as described in this manual.
ï‚· Ensure that the required voltage and frequency (220-240V/50 Hz)
match the available power source.
ï‚· Fuse style 5ET o SMT the electricity passing through the fuse cannot
be above 3.15A.
ï‚· This appliance can be used by children aged from 8 years and above
and people with reduced physical, sensory or mental capabilities or
lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe
way and understand the hazards involved.
ï‚· Children shall not play with the appliance.
ï‚· Cleaning and user maintenance shall not be made by children
without supervision.
ï‚· Ensure that the electricity system is able to deliver the operating
current required by the air conditioner, in addition to that normally
absorbed by other appliances (household appliances, lighting
system, etc.). Please refer to the maximum power input data
indicated on the air conditioner's data plate.
ï‚· Connection to the electricity grid must take place in accordance with
current installation standards.
ï‚· Ensure that the automatic switches and system protection valves are
able to withstand a start-up current of 6A (normally for less than 1
second).
ï‚· The system socket must always be fitted with an efficient earth
connection.
ï‚· Make sure that the plug is fully inserted. Do not use multiple
adapters. Do not touch the plug with wet hands. Make sure that the
plug is clean.
ï‚· Do not use the plug as a means by which to start/stop the air
conditioner: use the ON/OFF button on the remote control or on the
control panel.


Product specificaties

Merk: Argoclima
Categorie: Airco
Model: Madison
Soort bediening: Touch
Kleur van het product: Wit
Ingebouwd display: Ja
Timer: Ja
Gewicht: 23000 g
Breedte: 420 mm
Diepte: 360 mm
Hoogte: 720 mm
Netbelasting: 1010 W
Geluidsniveau: 65 dB
Soort: Mobiele airconditioner uit één stuk
Gebruikershandleiding: Ja
Aantal snelheden: 3
Aan/uitschakelaar: Ja
Koelend medium: R290
Type timer: Digitaal
Ingebouwde ventilator: Ja
Land van herkomst: China
Automatische temperatuurcontrole: Ja
Technologie: Lucht - lucht
Instelbare thermostaat: Ja
Air conditioner functies: Cooling, Dehumidifying, Ventilating
Jaarlijks energieverbruik (koelen): - kWu
Energie-efficiëntieklasse (koeling): A
Luchtfilter: Ja
Op afstand bedienbaar: Ja
Slang diameter: 150 mm
Lengte van slang: 1.5 m
Handvat(en): Ja
Koelcapaciteit in watt (opgegeven): 2630 W
Energieverbruik per uur (koeling): 1 kWu
Energieverbruik per uur (verwarming): - kWu
Auto-herstart: Ja
Ontvochtiging capaciteit: 1 L/u
Luchtstroom (hoge snelheid): 400 m³/uur
Koelcapaciteit (max): 10000 BTU/h
Koel capaciteit in watt (max): - W
Verwarmingscapaciteit in watt (max): - W
Koeling energie efficientie: 2.6
Verwarmingscapaciteit in watt (opgegeven): - W
Energie-efficiëntieklasse (verwarming): Nee
Afstandsbediening inbegrepen: Ja
AC-ingangsspanning: 220 - 240 V
AC-ingangsfrequentie: 50 Hz
Koelkast medium gewicht: 230 g
Type beeldscherm: LED
Energie-efficiëntieschaal: A+++ tot D
Zwenkwieltjes: Ja
Dehumidifier function: Ja
Timerduur (maximum): 24 uur
Comfort-slaapstand: Ja

Heb je hulp nodig?