Argoclima Ayri Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Argoclima Ayri (38 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 49 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/38
MOVABLE AIR CONDITIONER
C
LIMATIZZATORE PORTATILE
C
LIMATI
S
EUR M
O
BILE
MOBILES KLIMAGER
ÄT
ACO
NDI
C
I
O
NAD
O
R P
O
RTATIL
A
R CONDICIONADO PORTÁTIL
OPERATING INSTRUCTIONS
ISTRUZIONI D'USO
NOTICE D’UTILISATION
BEDIEN
N
ANLEIT
N
IN
S
TR
UCC
I
O
NE
S
DE
USO
INSTRUC
Ç
ÕES DE FUNCIONAMENTO
E
G
I
F
D
E
Save these instructions / Conservate
q
ueste istruzioni / Conserver cette notice d’utilisation
ewahren Sie bitte diese Bedienungsanleitungen auf / Guardeis estas instrucciones / Guarde estas instru
ç
ões
P
03/2013
2
3. Handle
7 Connection for Hot air exhaust hose.
EG
PRODUCT IDENTIFICATION................................................................................. 2
CONTROL PANEL ................................................................................................. 3
BEFORE USING THE APPLIANCE ....................................................................... 3
OPERATION ........................................................................................................... 4
EXHAUST HOSE KIT INSTALLATION .................................................................. 6
OPERATION with remote control ............................................................................ 5
CARE AND CLEANING .......................................................................................... 6
USEFUL ADVICE .............. .- CONTINUOUS DRAINAGE- .................................. . 7
DECLARATION OF CONFORMITY
This product is marked as it
satisfies Directives:
Low voltage no. 2006/95/CE.
Electromagnetic compatibility no.
no. 89/336 EEC, 92/31 EEC
and 93/68 EEC.
This declaration will become void in
case of of misusage and/or non
observance though partial of
manufacturer's installation and/or
operating instructions.
Operating limits:
Room Temperature:
ooling: MIN: 16°C D.B. / 12°C W.B.Co
M
AX:
3
C
D.B.
/
24°
C
W.B.
e
humidification: MIN: 10°C D.B / 80
%
R.H.
De
M
AX: 32°C D.B. / 80% R.H.
INF
O
RMATI
O
N F
O
R
CO
RRE
C
T DI
S
P
OS
AL
O
F THE PR
O
DU
C
T IN A
CCO
RDAN
C
E WITH THE EUR
O
PEAN
DIRE
C
TIVE 2002
/
96
/
E
C
A
t the end o
f
its working li
f
e this equipment must not be disposed o
f
as an household waste.
I
t must
b
e ta
k
en to spec
i
a
l
l
oca
l
commun
i
ty waste co
ll
ect
i
on centres or to a
d
ea
l
er prov
idi
ng t
hi
s serv
i
ce.
Disposing o
f
an electrical and electronic equipment separately avoids possible negative e
ff
ects on the environment and
human health deriving
f
rom an inappropriate disposal and enables its components to be recovered and recycled to obtain
significant savings in energy and resources.
In order to underline the duty to dispose o
f
this equipment separately, the product is marked with a crossed-out dustbin
.
C
O
NTENT
S
NOTE: OPEN the AIR OUTLET GRILLE
BEFORE USING THE UNIT
5 Air filter.
6 .-8 Return air grilles
9 Powe supply cord.
4 Wheels.
10 Water outlet drain (for continuous drainage in coooling mode).
11 Water outlet drain (for continuous drainage in dehumidify only mode).
PRODUCT IDENTIFICATION
1. Control panel and remote control place
2. Air outlet grille to be opened before using the unit
11
9
WARNING! Do not stick anything into the air outlet of the air conditioner. This is very dangerous because the fan is rotating at high speed.
WARNING! The air conditioner is provided with a time-guard system, which does not allow re-starting of compressor until after 3 minutes
from a previous stop.
Make sure that there are no obstacles around the unit affecting the free circulation of air. Do not block the air intake and outlet of the unit
with curtains or other. Never put objects on the top of the unit. Make sure that the back of the unit is at least 10 cm from a wall.
The manufacturer assumes no responsibilities if the safety regulations or local codes are not observed.
1. Always unplug the unit from the power socket before moving or cleaning it.
BEFORE USING THE APPLIANCE
EG
Cooling / Dehumidification/ Fan modes symbols
High / Med / Low fan speed symbols
Indicator of room temperature
Lamp for full water tank:
Display timer setting of auto switch on/off
Check that the power supply at the location where the air conditioner is going to be used is
220-240V ~ 50Hz .
Make sure that the electrical installation is suitable to supply continuously current necessary
for the air conditioner in addition to that already used by other electric appliances (white
goods, lighting). See the max electric input indicated on the name plate positioned on the air
conditioner.
The unit has to be connected according to the local electrical rules.
Make sure that circuit breakers, fuses, etc, are of sufficient capacity to handle a start-up cur-
rent of 20 A (generally less then 1 second).
Do not install the air conditioner where it could be wetted by drops of water (i.e. in laundries).
Make sure that the ON - OFF button switch on the control panel of the air conditioner is
in OFF position.
Before connecting the air conditioner to a power socket, make sure that the socket is provid-
ed with an earth connection in compliance with local codes.
Never use the power plug as a mean to start or stop the air conditioner: always use the
ON/OFF button switch on the air conditioner control panel.
Do not move the air conditioner during operation, turn it off and disconnect the plug from the
power supply. Verify and eventually discharge the condensate water, through the discharge
tube located on the rear of the unit.
WARNING
CONTROL
O
L PANE
L
Indication symbols on LCD and panel buttons functions
2 If the power cord is damaged, it must be replaced by the manufacturer, its service agent or other qualified person to avoid a hazard..
3. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety.
Mode selection button
3
Power control button
Fan speed slection button
WARNING: ALWAYS OPEN the AIR OUTLET GRILLE BEFORE USING THE APPLIANCE


Product specificaties

Merk: Argoclima
Categorie: Airco
Model: Ayri
Ingebouwd display: Ja
Gewicht: 29000 g
Koelend medium: R410A
Air conditioner functies: Koeling
Energie-efficiëntieklasse (koeling): A
Ontvochtiging capaciteit: 1 L/u
Luchtstroom (hoge snelheid): 270 m³/uur
Luchtstroom (medium snelheid): 260 m³/uur
Luchtstroom (lage snelheid): 240 m³/uur
Koelcapaciteit (max): 8000 BTU/h
Koel capaciteit in watt (max): 2300 W
Koeling energie efficientie: 2.7

Heb je hulp nodig?

Als je hulp nodig hebt met Argoclima Ayri stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco Argoclima

Handleiding Airco

Nieuwste handleidingen voor Airco