PORTABLE AIR CONDITIONER (LOCAL)
OPERATING INSTRUCTIONS
Read the instructions carefully before operating the appliance or carrying out maintenance work.
Observe all the safety instructions; failure to do so may lead to accidents and/or damage. Store these
instructions in a safe place for future reference.
EN
15
V 11/17
This appliance is a portable air conditioner designed for domestic
use.
Only use this air conditioner as described in this manual.
Ensure that the required voltage and frequency (220 240 V / 50 Hz) -
match the available power source.
Fuse style 50F 250V, the electricity passing through the FSD or
fuse cannot be above 3.15A.
This appliance can be used by children older than 8 years and by
people with reduced physical, sensory or mental abilities, or who
lack sufficient experience or the necessary knowledge, provided
that they are supervised or have been instructed on how to use the
appliance safely and understand the hazards related to its use.
Children must not be allowed to play with the appliance.
Cleaning and maintenance operations normally carried out by the
user must not be performed by unsupervised children.
Ensure that the electrical system is able to deliver the operating
current required by the air conditioner, in addition to that normally
absorbed by other appliances (electrical appliances, lighting system,
etc.). Please refer to the maximum power input data shown on the
air conditioner's data plate.
Connection to the electricity grid must take place in accordance with
current installation standards.
Ensure that the automatic switches and system protection valves
are able to withstand a start current of 6A (normally for less than -up
1 second).
The power socket must always include an efficient earth connection.
Make sure that the plug is properly inserted into the socket. Do not
use multiple adapters. Do not touch the plug with wet hands. Make
sure that the plug is clean.
Do not use the plug for starting/stopping the air conditioner: use the
ON/OFF button on the remote control or control panel instead.
16
V 11/17
Do not install the air conditioner in rooms potentially subject to water
sprays (e.g. laundries).
This air conditioner can be used by children of 8 years or older and
by persons with reduced physical, sensory and mental abilities, or
lacking the necessary experience and knowledge, provided they are
supervised or instructed on its use by a person responsible for their
safety, so that they are fully aware of the attendant risks.
Before moving or cleaning the appliance, ensure that it is unplugged
from the socket.
Do not move the air conditioner while it is operating; rst turn the
appliance off, then check and remove any condensate which may
have formed.
To turn the appliance off, set the remote control to OFF and remove
the plug from the socket. Pull on the plug only. Do not pull the cord.
Do not use the appliance if the cord or plug are damaged.
Contact a service centre to replace a damaged power cord, so as to
avoid any safety risks.
PRECAUTION!
Do not insert any objects into the air conditioner: this is very
dangerous as the fan turns at high speed.
Ensure that air circulates freely around the unit. Do not cover
the air intake and delivery grilles with drapes or any other
means.
WARNING!
The air conditioner must be positioned from the wall at least 50 cm
or any other obstacles, on a flat and stable surface so as to avoid
water leaks.
The air conditioner is fitted with a system for protecting the
compressor from overload. This means that the compressor
only starts 3 minutes after its previous stoppage.


Product specificaties

Merk: Argo
Categorie: Airco
Model: Kenny
Kleur van het product: Wit
Ingebouwd display: Ja
Timer: Ja
Gewicht: 21000 g
Breedte: 328 mm
Diepte: 305 mm
Hoogte: 678 mm
Geluidsniveau: 65 dB
Soort: Mobiele airconditioner uit één stuk
Aantal snelheden: 2
LED-indicatoren: Ja
Stroom: 1 A
Koelend medium: R410A
Automatisch uitschakelen: Ja
Type timer: Digitaal
Ingebouwde ventilator: Ja
Certificering: CE
Air conditioner functies: Cooling,Dehumidifying,Fan
Jaarlijks energieverbruik (koelen): - kWu
Energie-efficiëntieklasse (koeling): A
Luchtfilter: Ja
Op afstand bedienbaar: Ja
Slang diameter: 150 mm
Lengte van slang: 1.5 m
Handvat(en): Ja
Koelcapaciteit in watt (opgegeven): 2050 W
Energieverbruik per uur (koeling): 0.8 kWu
Energieverbruik per uur (verwarming): - kWu
Ontvochtiging capaciteit: 0.875 L/u
Luchtstroom (hoge snelheid): 300 m³/uur
Luchtstroom (lage snelheid): 260 m³/uur
Koelcapaciteit (max): 8000 BTU/h
Koel capaciteit in watt (max): - W
Verwarmingscapaciteit in watt (max): - W
Koeling energie efficientie: 2.6
Verwarmingscapaciteit in watt (opgegeven): - W
Afstandsbediening inbegrepen: Ja
AC-ingangsspanning: 230 V
AC-ingangsfrequentie: 50 Hz
Koelkast medium gewicht: 300 g
Type beeldscherm: LED
Zwenkwieltjes: Ja
Timerduur (maximum): 24 uur
Comfort-slaapstand: Ja
Vermogens consumptie (koeling): 760 W

Heb je hulp nodig?

Als je hulp nodig hebt met Argo Kenny stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco Argo

Handleiding Airco

Nieuwste handleidingen voor Airco