Installation Manual
HyperPod System
990-5862-001
Publication Date: May 2017
Schneider Electric IT Corporation Legal Disclaimer
The information presented in this manual is not warranted by the Schneider Electric IT Corporation to be
authoritative, error free, or complete. This publication is not meant to be a substitute for a detailed operational
and site specific development plan. Therefore, Schneider Electric IT Corporation assumes no liability for
damages, violations of codes, improper installation, system failures, or any other problems that could arise
based on the use of this Publication.
The information contained in this Publication is provided as is and has been prepared solely for the purpose of
evaluating data center design and construction. This Publication has been compiled in good faith by Schneider
Electric IT Corporation. However, no representation is made or warranty given, either express or implied, as to
the completeness or accuracy of the information this Publication contains.
IN NO EVENT SHALL SCHNEIDER ELECTRIC IT CORPORATION, OR ANY PARENT, AFFILIATE OR
SUBSIDIARY COMPANY OF SCHNEIDER ELECTRIC IT CORPORATION OR THEIR RESPECTIVE
OFFICERS, DIRECTORS, OR EMPLOYEES BE LIABLE FOR ANY DIRECT, INDIRECT, CONSEQUENTIAL,
PUNITIVE, SPECIAL, OR INCIDENTAL DAMAGES (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR
LOSS OF BUSINESS, CONTRACT, REVENUE, DATA, INFORMATION, OR BUSINESS INTERRUPTION)
RESULTING FROM, ARISING OUT, OR IN CONNECTION WITH THE USE OF, OR INABILITY TO USE THIS
PUBLICATION OR THE CONTENT, EVEN IF SCHNEIDER ELECTRIC IT CORPORATION HAS BEEN
EXPRESSLY ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SCHNEIDER ELECTRIC IT
CORPORATION RESERVES THE RIGHT TO MAKE CHANGES OR UPDATES WITH RESPECT TO OR IN
THE CONTENT OF THE PUBLICATION OR THE FORMAT THEREOF AT ANY TIME WITHOUT NOTICE.
Copyright, intellectual, and all other proprietary rights in the content (including but not limited to software, audio,
video, text, and photographs) rests with Schneider Electric IT Corporation or its licensors. All rights in the
content not expressly granted herein are reserved. No rights of any kind are licensed or assigned or shall
otherwise pass to persons accessing this information.
This Publication shall not be for resale in whole or in part.
Table of Contents
HyperPod System Installation i
General Information ...............................................................................................1
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Loading Capacities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
HyperPod SKU List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Documentation Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Manual updates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Unpacking and Inspecting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Safety.....................................................................................................................4
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Safety Recommendations for the HyperPod System . . . . . . . . . . . . . . . . . . . . . . 5
Planning the Installation.........................................................................................6
General guidelines for installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Enclosures and Power Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Layout and Positioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
List of Recommended Tools. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Systems Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Basic configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Component Identification .....................................................................................10
HyperPod System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Vertical Posts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
FS-FM-1001-B - Vertical Post Assembly, 2750mm (Short) . . . . . . . . . . . . . . . .11
FS-FM-1002-B - Vertical Post Assembly, 3200mm (Tall) . . . . . . . . . . . . . . . . . .11
Width Beams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
FS-FM-2001-B - Width Beam Assembly, 1200mm . . . . . . . . . . . . . . . . . . . . . . .11
Telescoping Beams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
FS-FM-3001-B - Telescoping Beam . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
End Cap Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
FS-FM-4001-B - End Cap Assembly (Short)
FS-FM-4002-B - End Cap Assembly (Tall) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Door Frame Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
FS-DR-2001-B - Standard Door Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Door and Rail Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
FS-DR-1001-B - Door and rail assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Windows, Rails, and Side Brushes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
FS-WI-1001-U - Window Assembly (270 x 600) . . . . . . . . . . . . . . . . . . . . . . . . .16
FS-WI-1002-B - Window Rail Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
FS-WI-1003-B - Window Brush Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Row length brushes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
FS-AC-2001-U . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
1HyperPod System Installation
General Information
Features
The HyperPodâ„¢ is a free standing air containment system. Fully configured racks can be deployed or
removed from the HyperPod as necessary. Schneider Electric racks or other EIA-310-D racks can be
used in a HyperPod system.
The HyperPod includes the following features:
• Two heights available for vertical posts: Tall = 3200mm and Short = 2750mm
• Telescoping side beams can extend the HyperPod length from 8 to 12 ft.
• Additional telescoping beams can be added to the vertical posts to extend the Pod up to another
12 feet.
The basic HyperPod can be customized with the following accessories:
• Power Raceways
• Overhead ducts
• Rack space blanking panels
• Cantilever support arms
• Overhead support frame
• Door assemblies
• Height adapters accommodate multiple rack heights
• Lighting assembly
• End Row Power Transition Cabinets
• Drop roof
• Crossover tray
The HyperPod system provides a barrier between the hot exhaust and cold intake air streams in the IT
environment. The separation of the hot and cold air streams in the environment increases the efficiency
and effectiveness of the cooling system that supports the critical IT equipment. The separation will also
allow for an elevated supply-air temperature to be provided by the cooling system since the mixing of hot
and cold air is eliminated. The HyperPod System can be built using new or existing Schneider Electric
equipment. This containment system is compatible with row, room, or external cooling solutions and
available for cold or hot aisle containment.
This manual is a guide for the basic installation procedures for creating a HyperPod System
Loading Capacities
• End Frames (each): 550 lbs.
• Upper Telescoping Beams (each): 250 lbs.
• Large Cantilever (one side, system quantity is 2): 1500 lbs.
For balance, the load should be applied to both sides of the HyperPod. If Large Cantilevers are
installed on only one side, the max loading rating is 974 lbs.
• Mini Cantilever (one side, system quantity is 6): 200 lbs.
• Total System: 4000 lbs.
5HyperPod System Installation
Safety Recommendations for the HyperPod System
To reduce the possibility of injury or equipment damage, read and follow the safety recommendations.
Follow all local and agency safety requirements.
WARNING
TOOL USAGE HAZARD
Follow safety standards for all hand tools and power tools used. Read and follow the tool
manufacturer’s instructions. Follow the tool manufacturer’s recommendations and recognized
safety requirements for use of Personal Protection Equipment (PPE).
Failure to follow these instructions can result in death, serious injury, or equipment
damage.
CAUTION
WORKING HEIGHT HAZARD
The working height for the assembly process can exceed 2.3 meters (7.5 feet). The use of
stepladders or scaffolding will be required during assembly.
Failure to follow these instructions can result in serious injury or equipment damage.
CAUTION
LIFTING HAZARD
At least two people are required to install this equipment. Some parts may be heavy and/or
excessive in size. For items weighing more than 25 lbs (12 kg), use more than one person.
Failure to follow these instructions can result in serious injury or equipment damage.
CAUTION
NO STEP HAZARD
Ceiling panels are not designed to support weight. Never lean or walk on the ceiling panels.
DO NOT use ceiling panels to support power or data cables.
Failure to follow these instructions can result serious injury or equipment damage.
HyperPod System Installation8
List of Recommended Tools
Screwdriver
P1 and
P2 Phillips
Screwdriver
T-30, T-20, T-15
TORX
Standard
screwdriver Hex wrench
3 mm, 6 mm
Wrench
6, 7, 8, 10, 11,
13,14, 18, and
19mm
Tape measure Chalk line
Hex socket
6.3 mm, 7 mm,
10 mm, 15 mm Level
Drill with
standard, Phillips,
TORX bits
Rotary tool
(e.g. Dremel®)
T-square
120 cm (48 in.)
minimum Self-retracting knife Miter saw Metal files
T-square Scissors Lift Ladder Drill and concrete
bits


Product specificaties

Merk: Apc
Categorie: Niet gecategoriseerd
Model: FS-AC-4004-B
Gewicht: 480 g
Breedte: 148 mm
Diepte: 145 mm
Hoogte: 9 mm
Gewicht verpakking: 750 g
Breedte verpakking: 348 mm
Diepte verpakking: 226 mm
Hoogte verpakking: 78 mm
Compatibiliteit: APC HyperPod

Heb je hulp nodig?

Als je hulp nodig hebt met Apc FS-AC-4004-B stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Apc

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd