Apc ACRD200 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Apc ACRD200 (46 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 37 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/46
InRow® DX — Fluid-Cooled Air Conditioner
ACRD200, ACRD201
Installation Manual
990–3213E-001
Release Date: November 2021
www.se.com
Legal Information
The Schneider Electric brand and any trademarks of Schneider Electric SE and its
subsidiaries referred to in this guide are the property of Schneider Electric SE or its
subsidiaries. All other brands may be trademarks of their respective owners.
This guide and its content are protected under applicable copyright laws and
furnished for informational use only. No part of this guide may be reproduced or
transmitted in any form or by any means (electronic, mechanical, photocopying,
recording, or otherwise), for any purpose, without the prior written permission of
Schneider Electric.
Schneider Electric does not grant any right or license for commercial use of the guide
or its content, except for a non-exclusive and personal license to consult it on an "as
is" basis. Schneider Electric products and equipment should be installed, operated,
serviced, and maintained only by qualified personnel.
As standards, specifications, and designs change from time to time, information
contained in this guide may be subject to change without notice.
To the extent permitted by applicable law, no responsibility or liability is assumed by
Schneider Electric and its subsidiaries for any errors or omissions in the informational
content of this material or consequences arising out of or resulting from the use of the
information contained herein.
This manual contains general information, safety instructions, and guidance. Updates
may be published from time to time and are available upon request. This manual is
not a substitute for the user conducting a detailed operational and site-specific
development plan.
This product is for industrial use only. It should only be used for the functions for
which it has been designed as set out in this manual. User must evaluate and take
adequate precautions to address risks associated with use of this product in
environments and/or processes not specifically addressed in this manual (e.g. heavy
industry, medical, marine environments, railway, etc.).
This product should be installed, configured, used, serviced, maintained, replaced or
have similar work carried out on it only by suitably qualified, trained, experienced and
competent personnel who hold any necessary authorizations (e.g. licenses, permits
or certifications) to perform such work.User must ensure that all work is carried out in
compliance with the manufacturer’s instructions (including the product labels/
markings, technical specification manual, installation manual, and operation and
maintenance manual) and with all applicable laws, regulations, standards and
guidance (including standards and guidance applicable to the installation location).
All work must be carried out in a way that does not give rise to danger and using
appropriate personal protective equipment (PPE).
Schneider Electric shall not be responsible for any works carried out by anyone other
than Schneider Electric; or for integration or use of the product with other products
(including spare parts and software) that are neither approved nor provided by
Schneider Electric for such purposes; or for any non-Schneider Electric software,
firmware, information or memory data contained in, stored on, or integrated with this
product.
To the maximum extent permitted by applicable law, neither Schneider Electric nor
any of its affiliates shall be liable for any claims, costs, losses, damages, death or
injuries arising out of the improper use of this product or any failure to comply with
any of the above requirements.Schneider Electric’s quality management system is
ISO 9001 certified and the products are marked
ACRD200, ACRD201
Table of Contents
Safety............................................................................................................5
Important Safety Instructions — SAVE THESE INSTRUCTIONS....................5
Safety During Installation ............................................................................6
General Information....................................................................................7
Translation Reference.................................................................................7
Save These Instructions..............................................................................7
Manual Updates .........................................................................................7
Cross-Reference Symbol Used in This Manual .............................................7
Receiving and Inspecting the Equipment................................................8
Filing a Claim .............................................................................................8
Environmental Considerations.....................................................................8
Pressurized Equipment...............................................................................8
Radio Frequency Interference .....................................................................9
California Proposition 65—Warning Statement for California
Residents ..................................................................................................9
Storing the Cooling Unit Before Installation ..........................................10
Moving the Unit ......................................................................................... 11
Model Identification...................................................................................12
Component Identification.........................................................................13
Installing Kit .............................................................................................13
External Components (Front) ....................................................................14
Internal Components (Front)......................................................................15
Internal Components (Rear) ......................................................................16
Electrical Panel ........................................................................................17
Top Piping and Power Access Locations .................................................... 18
Bottom Piping and Power Access Locations..........................................18
Piping Diagrams .......................................................................................19
Connections...............................................................................................21
Power connections ................................................................................... 21
Wiring Cross-Section Ratings ..............................................................21
Piping Connections...................................................................................22
Room Preparation.....................................................................................23
Weights and Dimensions...................................................................... 24
Installation..................................................................................................25
Removing Doors and Panels .....................................................................25
Positioning the Equipment .....................................................................26
Service Access ...................................................................................26
Leveling the Equipment .......................................................................27
Stabilizing the Equipment .................................................................27
Joining the Equipment to Enclosures ....................................................28
Mechanical Connections..........................................................................29
Liquid Piping ............................................................................................29
Condensate Pump.................................................................................... 29
Leak Sensor (optional) ..............................................................................31
Electrical Connections..............................................................................33
Control Connections .................................................................................33
990-3213E-001 3


Product specificaties

Merk: Apc
Categorie: Niet gecategoriseerd
Model: ACRD200
Kleur van het product: Zwart
Gewicht: 199090 g
Gewicht verpakking: 237270 g
Soort: Vrijstaande rek
Afmetingen verpakking (BxDxH): 746 x 1137 x 2118 mm
Certificering: cUL Listed, C-tick, CE, UL Listed
Afmetingen (B x D x H): 300 x 1070 x 1991 mm
Rackcapaciteit: 42U
AC-ingangsspanning: 208 - 230 V
AC-ingangsfrequentie: 60 Hz
Luchtcirculatie: 2290 CFM
Koelmiddel: R410A

Heb je hulp nodig?

Als je hulp nodig hebt met Apc ACRD200 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Apc

Apc

Apc C2C Handleiding

17 September 2024
Apc

Apc AP7868 Handleiding

17 September 2024
Apc

Apc P8VNTG Handleiding

17 September 2024
Apc

Apc P62 Handleiding

17 September 2024
Apc

Apc AP7898 Handleiding

17 September 2024

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd

Electrolux

Electrolux STA9 Handleiding

23 November 2024
Electrolux

Electrolux UMP3 Handleiding

23 November 2024
Bosch

Bosch HEZ8TK36UC Handleiding

23 November 2024
Bosch

Bosch HEZ8ZZ36UC Handleiding

23 November 2024
Bosch

Bosch HDZIT301 Handleiding

23 November 2024
Bosch

Bosch HEZBS301 Handleiding

23 November 2024
LG

LG LX-330 Handleiding

23 November 2024
Bosch

Bosch KSZ2AVU00 Handleiding

22 November 2024