990-91538 10/2021
© 2021 Schneider Electric. All rights reserved.
Worldwide Customer Support
Customer support and warranty information is available at
www.se.com
Air Containment Adapter Kits
(300mm) Installation
ACCS2004 - ACCS2005 - ACCS2006 - ACCS2007
ACCS2004 and ACCS2005 compatible with ACRD101, ACRD301
ACCS2006 and ACCS2007 compatible with ERC301CW
IMPORTANT SAFETY INSTRUCTIONS
Receiving
Inspect the Equipment
Carefully inspect the shipment for visible signs of damage. If you detect shipping
damage, contact your shipping company immediately and Schneider Electric Customer
Support at www.se.com.
Storage
These components should be stored indoors and out of the weather. Do not allow the
panels to be exposed to the elements.
CAUTION
HEAVY EQUIPMENT HAZARD
• The kit components are heavy. Use caution when lifting.
• Wear appropriate personal protective equipment (PPE) and follow safe work
practices.
Failure to follow these instructions can result in injury or equipment damage.
NOTICE
• Leaving the kit components uncovered and exposed to the elements will cause
damage and void the factory warranty.
• Wipe the panels with a damp cloth to clean. Do not use solvents or abrasive
cleaners.
Inventory
Item Description Qty
Adapter side frame with door hinges 1
Grounding Wire
1 inside adapter door, 1 on inside rear of hinge side adapter frame.
2
Adapter door handle side frame 42U 1
ACCS2004 Door 1
Door Handle (installed on doors) 2
ACCS2006 Door 1
Door (Rear adapter kits) 1
Adapter top 1
Adapter bottom 1
EVA foam seal 2.0 x 20 x 2000 (mm) 1
Display RJ45 connector adapter (for use with ACRD101 only) 1
Display interface connector cable (for use with ACRD101 only) 2
M6 flanged hex nut 8
Washer M6 serrated 2
Washer Nylon ID 6 PD 12 6
M5 flanged hex nut 1
Screw M6 x 12 Pan head T30 Nylok 6
Screw M8 x 12 Flat head Nylok T30 4
Screw M5 x 10 Pan head T25 3
Screw M6 x 12 Pan head T30 1
Recycle or dispose of the packaging materials appropriately.
ns3367a
Tools Required (not provided)
Prepare the Cooling Unit
Each kit contains the parts for one (front or
rear) installation.
Refer to your cooling unit’s manual for in-
structions for the below tasks.
1. Disconnect the cable from the
display interface.
2. Remove the front and rear doors from the
cooling unit.
3. Remove the hinges from the
cooling unit, if applicable.
NOTE: 1. In existing rows of racks, the
joining brackets securing the racks and
cooling units together on the front side are
not removed.
2. All racks in the row must be level and
secured together with the joining brackets (at
the front) prior to installing the air
containment adapters.
T25 and T30 Torx
head screwdrivers
8-mm, 10-mm, 13-mm
wrenches
Scissors Level
ns3371a
Cooling Unit Display
Install Air Containment Kit Mounting Screws
Install six (6) M6 x 12 Pan head T30 screws and six (6) nylon
washers (provided) to the front and rear of the cooling unit in the
holes corresponding to the mounting holes in the Air Containment
frame. The screws are installed only halfway to leave room to
place the Air Containment frame over the screw heads.
Assemble the Air Containment Kit
Frame
Insert the four (4) threaded posts on top and
bottom parts through the holes at the top and
bottom of the left and right frame pieces.
Once the top and bottom are set into the side
frames, secure them with eight (8) M6 flanged
hex nuts using a 10-mm wrench.
NOTICE
Remove the Display Interface from the Cooling Unit Door. Save the Display Interface
and its mounting hardware for installation to the adapter door.
CAUTION
HEAVY EQUIPMENT HAZARD
Some of the components of the Air Containment Kit are heavy. It is recommended
that two (2) people lift and move the larger parts.
Failure to follow these instructions can result in injury or equipment damage.
Display from ACRD301
Save 2 screws
Save
3 screws
Save
2 screws
Display from ACRD101
ns3372a
ns3366a
Apply the Gasket Material
1. Cut the gasket material to size.
2. Peel the backing paper from the
gasket, exposing the glue.
3. Apply the gasket material to the top
and bottom of the frame, pressing to
secure the gasket in position.
Install the Air Containment Frame
1. Hang the Air Containment frame on the
screws leaving the washers between the
frame and the Cooling Unit.
2. Tighten the six (6) M6 x 12 Pan head T30
screws to secure the air containment frame to
the rack. Use a level (not provided) to make
sure the frame and Cooling Unit are level.
3. Lower and adjust the leveling feet of the
adapter using a 13-mm wrench (not provided)
while still using the level.
Attach the ground wire on the rear of the Air Containment frame to the rack in the row
next to the cooling unit using one (1) M6 serrated washer and one (1) M6 x 12 pan head
T30 screw (provided).
NOTE: There is a ground wire on all Air Containment frames.
Backing
ns3376a
ns3377a
ns3379a
Ground wire on
adapter frame
Attached to
rack frame
Install the Door
1. Install the door to the Air Containment frame by lifting the door until the receivers on
the door are positioned above the hinge pins on the frame and then lowering the door
until the receivers engage the hinge pins.
2. Attach the ground wire on the Air Containment frame to the threaded stud on the
door using one (1) M6 serrated washer and one (1) M5 flanged nut provided in the
hardware bag.
.
Install the Cooling Unit Display Interface
to the Adapter Door
Use the hardware saved when the display was
removed from the cooling unit to install the display
interface in the door of the adapter.
Install the cover (ACCS2004) to the door using four
(4) flanged hex nuts provided.
NOTE: For ACRD101 Cooling Units, the cable
extension and connector will be required. Install the
cable and connector to the display cable.
Join the Air Containment Adapters
When multiple Air Containment Kits are installed in a row of
racks, the adapter side frames are secured to the next side
frame in the row using three (3) M5 x 10 Pan head screws
provided in the hardware bag with your kit.
ns3381a
ns3387a


Product specificaties

Merk: Apc
Categorie: Niet gecategoriseerd
Model: ACCS2006
Kleur van het product: Zwart
Breedte: 300 mm
Rackcapaciteit: 42U
Code geharmoniseerd systeem (HS): 85389099

Heb je hulp nodig?

Als je hulp nodig hebt met Apc ACCS2006 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Apc

Apc

Apc SYNX-3573406 Handleiding

11 December 2024
Apc

Apc SYNX-980214 Handleiding

11 December 2024
Apc

Apc SBP3000RMHW Handleiding

4 December 2024
Apc

Apc C2C Handleiding

17 September 2024
Apc

Apc AP7868 Handleiding

17 September 2024
Apc

Apc P8VNTG Handleiding

17 September 2024
Apc

Apc P62 Handleiding

17 September 2024
Apc

Apc AP7898 Handleiding

17 September 2024

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd