READ CAREFULLY THE
PRODUCT INSTALLATION,
OPERATING AND MAINTENANCE MANUAL.
FAILURE TO FOLLOW THE INSTRUCTIONS AND
WARNINGS IN THE MANUAL MAY RESULT IN
SERIOUS OR FATAL INJURY AND/OR PROPERTY
DAMAGE, AND WILL VOID THE PRODUCT
WARRANTY. THIS PRODUCT MUST BE
INSTALLED BY A LICENSED PROFESSIONAL.
FOLLOW ALL APPLICABLE LOCAL AND STATE
CODES AND REGULATIONS, IN THE ABSENCE
OF SUCH CODES, FOLLOW THE CURRENT
EDITIONS OF THE NATIONAL PLUMBING CODE
AND NATIONAL ELECTRIC CODE,
AS APPLICABLE.
This Product, like most
Products under pressure,
may over time corrode, weaken and burst or explode,
causing serious or fatal injury, leaking or flooding and/
or property damage. To minimize risk, a licensed
professional must install and periodically inspect and
service the product. A drip pan connected to an
adequate drain must be installed if leaking or flooding
could cause property damage. Do not locate in an
area where leaking could cause property damage to
the area adjacent to the appliance or to lower floors
of the structure.
The recurrence of pressure
buildup may indicate that this
unit is in need of replacement. Operating a plumbing
system in this condition presents the risk of damage
and leaks.
RUPTURE OR EXPLOSION
HAZARD. Do not expose
Product to freezing temperatures or water
temperatures in excess of . Failure to properly 140°F
size the product or follow these instructions may
result in excessive strain on the system and may lead
to product failure, serious or fatal personal injury,
leakage and/or property damage. USE ONLY WITH
RESIDENTIAL POTABLE WATER SYSTEMS.
A relief valve must be
installed to prevent pressure
in excess of local code requirement or maximum
working pressure of 150 psig, whichever is less. At
least once every 3 years or if discharge is present, a
licensed professional should inspect the temperature
and pressure relief valve and replace if corrosion is
evident or the valve does not function. FAILURE TO
INSPECT THIS VALVE AS DIRECTED COULD
RESULT IN UNSAFE TEMPERATURE OR
PRESSURE BUILD-UP WHICH CAN RESULT IN
PRODUCT FAILURE, SERIOUS INJURY OR
DEATH AND/OR SEVERE PROPERTY DAMAGE
AND VOID THE PRODUCT WARRANTY.
Chlorine & Aggressive
Water: The water quality can
significantly influence the life of this product. You
should test for corrosive elements, acidity, total solids
and other relevant contaminants, including chlorine
and treat your water appropriately to insure
satisfactory performance and prevent premature
failure.
NOTE: Inspect for shipping damage. Notify freight carrier or store where purchased immediately if damage is
present. To avoid risk of personal injury and property damage, if the product appears to be malfunctioning or shows
signs of corrosion, call a qualified professional immediately. Current copies of the product manual can be viewed at
www.amtrol.com. Use proper safety equipment when installing.
THIS IS THE SAFETY ALERT SYMBOL. IT IS USED TO ALERT YOU TO POTENTIAL PERSONAL
INJURY AND OTHER HAZARDS. OBEY ALL SAFETY MESSAGES THAT FOLLOW THIS SYMBOL
TO REDUCE THE RISK OF PERSONAL INJURY AS WELL AS PROPERTY DAMAGE.
Model ST-1
THERMAL EXPANSION TANK
FOR POTABLE WATER
INSTALLATION & OPERATION INSTRUCTIONS
Application
The ST-1 expansion tank is for use on tankless,
residential on-demand water heaters with a total
water content of 2 gallons or less and a maximum
set point of 140°F. Do not use with larger storage-
type water heaters, as these will exceed the
capacity of the ST-1.
Installation
1. Install the expansion tank on the cold water
supply line to the water heater at a point
between the water heater and backflow
preventer or other one-way device (Figure 1).
2. Once the expansion tank is installed, check
the cold water supply line for any leakage.
Make repairs if necessary.
3. Before the initial firing of the water heater,
open a hot water fixture and draw for one
minute to purge air. Next, close and open the
fixture in 30 second intervals, repeating three
thimes to flush the tank and piping.Finally,
turn the water heater temperature control to
desired ending temperature (see water heater
instructions). Do not set temperature higher
than the expansion tank maximum.
4. To relieve initial thermal expansion, slightly
open a hot water faucet. Continue until water
heater temperature is satisfied. Once heater is
at its operating range, no further bleeding of
expanded water is required.
5. The water heater and expansion tank will
now be operational. The expansion tank
will control pressure increases caused by
thermal expansion to a level below the water
heater relief valve setting. FOR USE ON
TANKLESS RESIDENTIAL ON DEMAND
WATER HEATERS WITH A TOTAL WATER
CONTENT OF 2 GALLONS OR LESS AND
A MAXIMUM SET POINT OF 140° F. NON-
ADJUSTABLE PRECHARGE.
PSI Volume (cu.in.) Weight (lb.)
.00 0.00 .87
20.00 3.92 1.01
40.00 5.77 1.07
60.00 7.43 1.13
80.00 8.17 1.16
100.00 8.63 1.18
120.00 9.00 1.19
140.00 9.27 1.20
150.00 9.27 1.20
Maintenance
A licensed professional should check the
complete system, including the expansion tank,
yearly and more frequently as the system ages.
Warranty
ST-1 Model: Seven (7) Year Limited Warranty
Visit www.amtrol.com for complete warranty
details.
PLEASE READ THE FOLLOWING INSTRUCTIONS CAREFULLY
IMPORTANT GENERAL SAFETY INFORMATION -
ADDITIONAL SPECIFIC SAFETY ALERTS APPEAR IN THE FOLLOWING INSTRUCTIONS.
1400 Division Road, West Warwick, RI 02893 USA
T: 800.426.8765 www.amtrol.com
© 2020 Worthington Industries Inc. Part #: 9013-017 (01/21)
One or more features of this product are covered by U.S. patents, visit www.amtrol.com/patents for more information.
Figure 1. Typical Installation
ST-1
Thermal
Expansion Tank
Hot Water
T & P
Relief
Valve
Cold
Water
Supply
Backflow Preventor
Check Valve or
Pressure Reducing Valve
Water
Heater
Product specificaties
Merk: | Amtrol |
Categorie: | Ketel & boiler |
Model: | Therm-X-Trol ST-1 |
Heb je hulp nodig?
Als je hulp nodig hebt met Amtrol Therm-X-Trol ST-1 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Ketel & boiler Amtrol
29 Juli 2023
28 Juli 2023
28 Juli 2023
28 Juli 2023
28 Juli 2023
28 Juli 2023
28 Juli 2023
28 Juli 2023
28 Juli 2023
28 Juli 2023
Handleiding Ketel & boiler
- Ketel & boiler Electrolux
- Ketel & boiler Bosch
- Ketel & boiler Philips
- Ketel & boiler Panasonic
- Ketel & boiler AEG
- Ketel & boiler ATAG
- Ketel & boiler BEKO
- Ketel & boiler Inventum
- Ketel & boiler Junkers
- Ketel & boiler Nefit
- Ketel & boiler Remeha
- Ketel & boiler Siemens
- Ketel & boiler Vaillant
- Ketel & boiler Whirlpool
- Ketel & boiler A.O. Smith
- Ketel & boiler ACV
- Ketel & boiler Adler
- Ketel & boiler Arcelik
- Ketel & boiler Atlantic
- Ketel & boiler AWB
- Ketel & boiler Buderus
- Ketel & boiler Buffalo
- Ketel & boiler Bulex
- Ketel & boiler Burco
- Ketel & boiler Daalderop
- Ketel & boiler Daikin
- Ketel & boiler De Dietrich
- Ketel & boiler Dimplex
- Ketel & boiler Dometic
- Ketel & boiler Easypix
- Ketel & boiler Eccotemp
- Ketel & boiler Edilkamin
- Ketel & boiler Elco
- Ketel & boiler ETA
- Ketel & boiler Fagor
- Ketel & boiler Fakir
- Ketel & boiler Ferroli
- Ketel & boiler Franke
- Ketel & boiler GE
- Ketel & boiler Gorenje
- Ketel & boiler Haier
- Ketel & boiler Hisense
- Ketel & boiler Hitachi
- Ketel & boiler Hotpoint
- Ketel & boiler Intergas
- Ketel & boiler Kelvinator
- Ketel & boiler La Nordica
- Ketel & boiler LEMET
- Ketel & boiler Midea
- Ketel & boiler Morco
- Ketel & boiler Nibe
- Ketel & boiler Plieger
- Ketel & boiler Qlima
- Ketel & boiler Quantum
- Ketel & boiler Quooker
- Ketel & boiler Rommelsbacher
- Ketel & boiler Sencor
- Ketel & boiler Sentry
- Ketel & boiler Solac
- Ketel & boiler Stiebel Eltron
- Ketel & boiler Taurus
- Ketel & boiler Technika
- Ketel & boiler Teka
- Ketel & boiler Thermor
- Ketel & boiler Truma
- Ketel & boiler Viessmann
- Ketel & boiler Waeco
- Ketel & boiler Wahlbach
- Ketel & boiler Wesen
- Ketel & boiler Wijas
- Ketel & boiler Ygnis
- Ketel & boiler Jocel
- Ketel & boiler Camry
- Ketel & boiler Concept
- Ketel & boiler Elba
- Ketel & boiler Guzzanti
- Ketel & boiler Khind
- Ketel & boiler Orbegozo
- Ketel & boiler Vox
- Ketel & boiler Kunft
- Ketel & boiler Aspes
- Ketel & boiler Corberó
- Ketel & boiler Infiniton
- Ketel & boiler Respekta
- Ketel & boiler Svan
- Ketel & boiler Eldom
- Ketel & boiler HTW
- Ketel & boiler Mora
- Ketel & boiler Cata
- Ketel & boiler Tesy
- Ketel & boiler Rommer
- Ketel & boiler Baxi
- Ketel & boiler Worcester
- Ketel & boiler Rinnai
- Ketel & boiler Clage
- Ketel & boiler Cointra
- Ketel & boiler IQE
- Ketel & boiler Keston
- Ketel & boiler Sime
- Ketel & boiler Biasi
- Ketel & boiler Duwaco
- Ketel & boiler Masterwatt
- Ketel & boiler OSO
- Ketel & boiler Ariston Thermo
- Ketel & boiler Cola
- Ketel & boiler TTulpe
- Ketel & boiler Noveen
- Ketel & boiler Joven
- Ketel & boiler Country Comfort
- Ketel & boiler Rheinstrom
- Ketel & boiler Thermoflow
- Ketel & boiler Wagaparts
- Ketel & boiler SolarEdge
- Ketel & boiler LERAN
- Ketel & boiler Dux
- Ketel & boiler Intellihot
- Ketel & boiler Airthereal
- Ketel & boiler IStore
- Ketel & boiler Apricus
- Ketel & boiler Aquamarin
- Ketel & boiler Hydrotherm
- Ketel & boiler Kospel
- Ketel & boiler Neopower
- Ketel & boiler Gleamous
- Ketel & boiler AquaMAX
- Ketel & boiler My-PV
- Ketel & boiler EvoHeat
- Ketel & boiler Rheem
- Ketel & boiler Mission Air
- Ketel & boiler Solahart
- Ketel & boiler ENEFT
- Ketel & boiler AquaTech
- Ketel & boiler Imarflex
- Ketel & boiler MicroHeat
- Ketel & boiler Noritz
Nieuwste handleidingen voor Ketel & boiler
14 December 2024
11 December 2024
11 December 2024
10 December 2024
10 December 2024
10 December 2024
10 December 2024
10 December 2024
10 December 2024
10 December 2024