Amcor ALTL12000EH Handleiding
Amcor
Airconditioner
ALTL12000EH
Lees hieronder de 📖 handleiding in het Nederlandse voor Amcor ALTL12000EH (8 pagina's) in de categorie Airconditioner. Deze handleiding was nuttig voor 41 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/8
It is important that you read
these instructions before
using your new purchase and
we strongly recommend that
you keep them in a safe place
for future reference.
Owner’s Manual
Dear Customer: Please keep this warranty for your record.
DO NOT
return it.
9131
24000
One Year Limited Warranty
Amcor, Inc. (“Amcor”) warrants the original retail purchaser (“Purchaser”) purchasing in the
United States that the Amcor product with which this warranty is enclosed is free from defects
in materials and workmanship.
Amcor’s sole obligation under this warranty is to replace, or at Amcor’s discretion, to repair,
free of charge, all defective parts, for a period of one (1) year from date of original purchase.
ANY IMPLIED WARRANTY OF MERCHANTABILITY IS SIMILARLY LIMITED TO ONE (1)
YEAR FROM DATE OF ORIGINAL PURCHASE AND NO ACTION BASED UPON ANY
IMPLIED WARRANTY OF MERCHANTABILITY OR OTHERWISE MAY BE COMMENCED
AFTER EXPIRATION OF ONE (1) YEAR FROM DATE OF ORIGINAL RETAIL PURCHASE.
Some states do not allow limitations on how long an implied warranty lasts, so the above limitation
may not apply to you.
The provisions of this warranty shall not apply to any product which in Amcor’s judgment has
been (1) subject to misuse or neglect. (2) damaged in an accident. (3) used for a purpose for
which it was not designed, or (4) repaired or altered in any way that adversely affected its
performance or reliability.
To obtain warranty service, the defective product or part must be shipped or delivered to:
Amcor’s authorized service center. All postage, insurance and shipping charges are the responsibility
of the Purchaser and are not included in this warranty.
AMCOR NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO ASSUME FOR IT ANY
OTHER ( LIABILITY IN CONNECTION WITH ITS PRODUCTS, THERE ARE NO WARRANTIES
WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. NO RESPONSIBILITY
IS ASSUMED FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES THAT MAY RESULT FROM
THE USE OF AN AMCOR PRODUCT, NOR FOR THE DAMAGES DUE TO ACCIDENT, ABUSE,
LACK OF RESPONSIBLE CARE, THE AFFIXING OF ANY UNAUTHORIZED ATTACHMENT,
LOSS OF PARTS, OR USE AT A VOLTAGE OTHER THAN SPECIFIED. Some states do not allow
the exclusion of limitation
of incidental or consequential damages, so these limitations may not
apply to you.
Amcor disclaims all liabilities for defects or damages caused by use of replacement parts obtained
from or by service at any service center other than Amcor’s authorized service center.
This warranty gives you specific legal rights, and you may also have other rights which vary from
state to state.
Product:
AMCOR Portable Air Conditioner
Date Purchased:_____________________________________ Production Code:________
QUESTIONS? Call 866-361-2233 · www.amcorgroupusa.com
14
3/2006
PORTABLE
PORTABLE
Air Conditioner
Air Conditioner
For models ALTL -12
For models ALTL -12
,
000E and ALTL -12
,
000EH
Model: ALTL -12
,
000E/EH
1
Table of Contents
THANK YOU...............................................................................................................................2
Energy Saving Tips .......................................................................................................................................................2
SPECIFICATIONS........................................................................................................................3
BEFORE USE.................................................................................................................................4
PARTS ............................................................................................................................................5
Accessories.....................................................................................................................................................................5
INSTALLATION ..........................................................................................................................6
Window Kit Installation..............................................................................................................................................6
Wall Connection ...........................................................................................................................................................6
Mounting the Exhaust Pipe.......................................................................................................................................7
Cleaning the Filter........................................................................................................................................................7
OPERATION................................................................................................................................8
Control Panel.................................................................................................................................................................8
Setting On/Off...............................................................................................................................................................8
Setting the Temperature.............................................................................................................................................8
Mode Switch .................................................................................................................................................................8
Setting Fan Speed ........................................................................................................................................................8
Setting the Timer..........................................................................................................................................................8
Programmimg the Timer.............................................................................................................................................9
Repeat Function ...........................................................................................................................................................9
Canceling the Timer Function....................................................................................................................................9
Regulating the Airflow Direcrion .............................................................................................................................10
DRAINAGE..................................................................................................................................11
How to Drain the Unit ..............................................................................................................................................11
MAINTENANCE ........................................................................................................................12
Cleaning the Housing ................................................................................................................................................12
End of Season Storage ..............................................................................................................................................12
Storing the Power Cord............................................................................................................................................12
TROUBLESHOOTING .............................................................................................................13
WARRANTY ...............................................................................................................................14
12
Maintenance
Always unplug the unit from the wall outlet before beginning
the cleaning.
Cleaning the Housing
Use a soft, damp cloth to wipe the body clean.
Never use strong chemicals, oil-based products, detergents, chemically treated cloths or other
cleaning solutions. These could possibly damage the cabinet.
Cleaning the Filter
Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters and then
rinse them thoroughly under running water (no hotter than 104
°
F).
Dry thoroughly before replacing.
Do not wet the activated carbon filter, remove from frame before rinsing.
IMPORTANT! Never operate the unit without the filters.
End of Season Storage
Unplug the unit.
Drain the condensed water COMPLETELY (please refer to page 1
1
).
Clean or change the filter.
On a warm day, turn the unit to fan mode for a couple of hours so that the
inside can dry out completely.
It is recommended that the unit be put back into its original carton for storage.
Do not stack heavy objects on top of the unit.
Storing The Power Cord
When the unit is not in use, please store the power cord away as shown in Figure 3.
Fig. 3
Cleaning the Filter ......................................................................................................................................................12
10
3
Specifications
Model Number
ALTL-12,000E
ALTL-12,000EH
Cooling Capacity
12,000 BTU/hr
12,000 BTU/hr
Heating Capacity
N/A
12,000 BTU/hr
Power Consumption
950W / 8.4A
950W / 8.4A
Humidity Removal Capacity 65 Pts. / Day
65 Pts. / Day
Recommended room size* Up to 400 sq. ft.
Up to 400 sq. ft.
Power Supply
115V / 60Hz / 1 Phase 115V / 60Hz / 1 Phase
Compressor
Rotary
Rotary
Refrigerant
R-22
R-22
Fan Speed
2
2
Timer
1-2
4
hours
1
-2
4
hours
Temperature Set Range
62
°
F - 90
°
F 6
2
°
F - 90
°
F
Unit Weight
65 lbs.
68 lbs.
Dimensions
16"W x 17"D x 30"H 16"W x 17"D x 30"H
Working Temperature
Cooling: 62
°
F to 110
°
F Cooling: 62
°
F to 110
°
F
Heating: 41
°
F to 81
°
F
REMARKS:
The cooling capacity of the unit may be affected by the height of the ceiling,
quality of insulation, number of windows, etc.
Operation
Turn the roller on the air vent to control
the airflow direction from the vertical louvers.
Move the air vent directly to adjust the
airflow direction from the horizontal louvers.
IMPORTANT!
• The compressor will start approximately 3 minutes after the unit is turned on (this will
help prolong the life of the compressor). After switching the unit off, please wait at least
3 minutes before turning the unit back on.
• The cooling system will switch off if the room temperature is lower than set. The fan, however, keeps
working at the set level. If the ambient temperature rises above the chosen temperature +/
-
5
°
F,
the cooling will resume.
• In heating mode, the compressor will switch off if the room temperature is HIGHER than the one set
(the fan keeps working at the set level). When the room temperature drops 5
°
F below the chosen
temperature, heating will resume.
• This machine is equipped with an ANTI-FROST function. Sometimes, while using the heating function
during low temperatures, the heating will stop for a while to melt the internal frost. When this occurs,
wait for heating to resume.
• As you switch on the heating, the fan will stop for 15-20 seconds prior to the unit starting.
Regulating the Airflow Direction
Mode
Temp. Up
Temp. Down
Speed
Timer
On/Off
18:00
18:00
12:00
00:00
ON
OFF
COMP
��������� :
0
0
06:00���
06:00���
24
Mode Temp. Up Temp. Down Speed
Timer On/Off
18:00
18:00
12:00
00:00
ON
OFF
COMP
��������� :
0
0
06:00���
06:00���
24
Product specificaties
Merk: | Amcor |
Categorie: | Airconditioner |
Model: | ALTL12000EH |
Heb je hulp nodig?
Als je hulp nodig hebt met Amcor ALTL12000EH stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Airconditioner Amcor
8 September 2022
8 September 2022
8 September 2022
8 September 2022
8 September 2022
8 September 2022
8 September 2022
8 September 2022
8 September 2022
8 September 2022
Handleiding Airconditioner
- Airconditioner Electrolux
- Airconditioner Bosch
- Airconditioner Samsung
- Airconditioner Panasonic
- Airconditioner LG
- Airconditioner AEG
- Airconditioner Bauknecht
- Airconditioner BEKO
- Airconditioner Daewoo
- Airconditioner Honeywell
- Airconditioner Inventum
- Airconditioner Toshiba
- Airconditioner Vaillant
- Airconditioner Whirlpool
- Airconditioner Zanker
- Airconditioner Zibro
- Airconditioner Acson
- Airconditioner Aermec
- Airconditioner Aertesi
- Airconditioner Aircool
- Airconditioner Aircooler
- Airconditioner Airlux
- Airconditioner Airview
- Airconditioner Airwell
- Airconditioner Akai
- Airconditioner Akira
- Airconditioner Alaska
- Airconditioner Alberello
- Airconditioner Andrews
- Airconditioner Argo
- Airconditioner Ariston
- Airconditioner Bryant
- Airconditioner D-Let
- Airconditioner Daikin
- Airconditioner Dimplex
- Airconditioner Domair
- Airconditioner Dometic
- Airconditioner Duux
- Airconditioner Edgestar
- Airconditioner Einhell
- Airconditioner Emerio
- Airconditioner Emmeti
- Airconditioner Eurom
- Airconditioner Fakir
- Airconditioner Frigor
- Airconditioner Fujitsu
- Airconditioner Galanz
- Airconditioner Gutfels
- Airconditioner H.Koenig
- Airconditioner Haier
- Airconditioner Handson
- Airconditioner Heiko
- Airconditioner Innova
- Airconditioner Kenmore
- Airconditioner Klarbach
- Airconditioner Klima1stKlaas
- Airconditioner Koenig
- Airconditioner Maiko
- Airconditioner MDV
- Airconditioner Mizushi
- Airconditioner Mobile Airco
- Airconditioner MPM
- Airconditioner MundoClima
- Airconditioner Qlima
- Airconditioner Qlima - Zibro
- Airconditioner Rowenta
- Airconditioner Shinco
- Airconditioner Sinclair
- Airconditioner SMD
- Airconditioner TechnoLife
- Airconditioner Telair
- Airconditioner Termozeta
- Airconditioner Thermo Comfort
- Airconditioner Tosot
- Airconditioner Trotec
- Airconditioner Ufesa
- Airconditioner Olimpia Splendid
- Airconditioner OneConcept
- Airconditioner Inventor
- Airconditioner Day
- Airconditioner Zymbo
Nieuwste handleidingen voor Airconditioner
18 Maart 2023
5 Februari 2023
5 Februari 2023
5 Februari 2023
2 Januari 2023
5 Februari 2023
4 Januari 2023
2 Januari 2023
8 Maart 2023