Dear Customer: Please keep this warranty for your record.
DO NOT
return it.
It is important that you read
these instructions before
using your new purchase and
we strongly recommend that
you keep them in a safe place
for future reference.
Owner’s Manual
ALD-12,000E and ALD-12,000EH
For models A
9131
24000
One Year Limited Warranty
Amcor, Inc. (“Amcor”) warrants the original retail purchaser (“Purchaser”) purchasing in the
United States that the Amcor product with which this warranty is enclosed is free from defect
in materials and workmanship
Amcor’s sole obligation under this warranty is to replace, or at Amcor’s discretion, to repair
free of charge, all defective parts, for a period of one (1) year from date of original purchase
ANY IMPLIED WARRANTY OF MERCHANTABILITY IS SIMILARLY LIMITED TO ONE (1
YEAR FROM DATE OF ORIGINAL PURCHASE AND NO ACTION BASED UPON ANY
IMPLIED WARRANTY OF MERCHANTABILITY OR OTHERWISE MAY BE COMMENCED
AFTER EXPIRATION OF ONE (1) YEAR FROM DATE OF ORIGINAL RETAIL PURCHASE
Some states do not allow limitations on how long an implied warranty lasts, so the above limitatio
may not apply to you
The provisions of this warranty shall not apply to any product which in Amcor’s judgment ha
been (1) subject to misuse or neglect. (2) damaged in an accident. (3) used for a purpose fo
which it was not designed, or (4) repaired or altered in any way that adversely affected its
performance or reliability.
To obtain warranty service, the defective product or part must be shipped or delivered to
Amcor’s authorized service center. All postage, insurance and shipping charges are the responsibility
of the Purchaser and are not included in this warranty
AMCOR NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO ASSUME FOR IT ANY
OTHER ( LIABILITY IN CONNECTION WITH ITS PRODUCTS, THERE ARE NO WARRANTIE
WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. NO RESPONSIBILITY
IS ASSUMED FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES THAT MAY RESULT FROM
THE USE OF AN AMCOR PRODUCT, NOR FOR THE DAMAGES DUE TO ACCIDENT, ABUSE
LACK OF RESPONSIBLE CARE, THE AFFIXING OF ANY UNAUTHORIZED ATTACHMENT
LOSS OF PARTS, OR USE AT A VOLTAGE OTHER THAN SPECIFIED. Some states do not allow
the exclusion of limitation
of incidental or consequential damages, so these limitations may not
apply to you.
Amcor disclaims all liabilities for defects or damages caused by use of replacement parts obtained
from or by service at any service center other than Amcor’s authorized service center
This warranty gives you specific legal rights, and you may also have other rights which vary from
state to state.
Product:
AMCOR Portable Air Conditioner
Model: ALD-12,000E/EH
Date Purchased:_____________________________________ Production Code:_______
QUESTIONS? Call 866-361-2233 · www.amcorgroupusa.com
14
1/2006
R T A B L E
P O
Conditioner
Air C
1
12
Table of Contents
THANK YOU.....................................................................................................................
..........2
Energy Saving Tips .............................................................................................................
..........................................2
SPECIFICATIONS .................................................................................................................
......3
BEFORE USE.....................................................................................................................
............4
PARTS ..........................................................................................................................
..................5
Front, Back ....................................................................................................................
.................................................5
Accessories....................................................................................................................
.................................................5
INSTALLATION ...................................................................................................................
.......6
Window Kit Installation........................................................................................................
......................................6
Wall Connection ................................................................................................................
...........................................6
Mounting the Exhaust Pipe......................................................................................................
.................................7
Cleaning the Filter............................................................................................................
............................................7
OPERATION......................................................................................................................
..........8
Control Panel..................................................................................................................
...............................................8
Setting Mode / Function........................................................................................................
.....................................8
Auto Mode......................................................................................................................
...............................................8
Setting the Temperature........................................................................................................
.....................................8
Setting Fan Speed..............................................................................................................
..........................................9
Setting the Timer ..............................................................................................................
............................................9
Regulating Airflow Direction ...................................................................................................
...................................9
DRAINAGE.......................................................................................................................
...........10
How to Drain the Unit ..........................................................................................................
....................................10
MAINTENANCE ....................................................................................................................
....11
Cleaning the Housing ...........................................................................................................
.....................................11
Cleaning the Filter ............................................................................................................
..........................................11
End of Season Storage..........................................................................................................
....................................11
Storing the Power Cord........................................................................................................
....................................11
TROUBLESHOOTING..............................................................................................................12
WARRANTY .......................................................................................................................
........14
Troubleshooting
REPLACEMENT FILTERS:
To purchase Replacement Filters for this unit, contact AMCOR at
1-866-361-2233 and request model number ALD-12,000F
If this product is defective or not working properly,
please DO NOT return to your retail store.
Please contact us directly for any Service or Technical Assistance at:
1-866-361-2233
Amcor Inc.
www.amcorgroupusa.com
Windows or doors Close doors and windows
are open.
The filter is dirty Clean or replace filter.
Air inlet or air Remove blockage.
outlet is blocked.
Room temperature lower Lower temperature selected.
than the selected value.
The overheat protection Wait 3 minutes until temperature
is activated. has decreased, then turn on again
No power supply Make sure outlet works
Be sure Green Light is on (L.C.D.I. Plug)
Press Re-start button
Water container is full. Drain the Unit.
Timer Function Set Deactivate the Timer Function
Unit is not standing Place on an even surface
on a level surface.
Distance too great. Make sure the remote is aimed
at the control panel.
Remote control signal not Control is aimed at the
detected by control panel. control panel.
Batteries are dead. Replace the batteries
If you have any questions regarding the operation of the ALD-12,000
please contact AMCOR at 1-866-361-2233
The Unit is Noisy
The Air Conditioner
Does Not Function
Properly
The Remote
Control Does
Not Function
Problem Cause Solution
Never try to repair or dismantle the air conditioner yourself. Tampering with the unit
may result in the loss of warranty and can endanger the user and property
The Unit
Does Nothing
10
3
Specifications
Model Number ALD-12,000E ALD-12,000EH
Cooling Capacity 12,000 BTU/hr 12,000 BTU/hr
Heating Capacity N/A 12,000 BTU/hr
Power Consumption 950W / 8.4A 950W / 8.4A
Humidity Removal Capacity 65 Pts. / Day 65 Pts. / Day
Recommended room size* Up to 400 sq. ft. Up to 400 sq. ft.
Power Supply 115V / 60Hz / 1 Phase 115V / 60Hz / 1 Phase
Compressor Rotary Rotary
Refrigerant R-22 R-22
Fan Speed 2 2
Timer 1-12 hours 1-12 hours
Temperature Set Range 62
°
F - 90
°
F 62
°
F - 90
°
F
Unit Weight 65 lbs. 68 lbs
Dimensions 16"W x 17"D x 30"H 16"W x 17"D x 30"H
Working Temperature Cooling: 62
°
F to 110
°
F Cooling: 62
°
F to 110
°
F
Heating: 41
°
F to 81
°
F
REMARKS:
The cooling capacity of the unit may be affected by the height of the ceiling,
quality of insulation, number of windows, etc.
Drainage
During the process of cooling, some water will be extracted from the air into the unit. Most of this water
is used to cool the unit and make it run more efficiently. This is a feature not found in most Portable Air
Conditioners. If the unit is operated in VERY HUMID air, water will collect in the container inside the unit.
If the Internal Water Container is full, the backlight on the LCD display will flash, the unit will shut off, and
it must be drained before it will re-start.
How to Drain the Unit
Use a Shallow Container or Dish
1. Turn off the unit.
2. Position a flat container or dish under the drain hole.
Do not allow the water to drip continuously into
the container, as it might easily overflow.
3. Remove the drain knob & rubber plug from
the drain hole.
The condensed water will drain out automatically.
4. When the container is almost full, replace the
rubber plug into the drain hole to stop the water.
Empty the container.
5. Repeat steps 2, 3 & 4 until all the condensed water
is emptied.
6. Once all the condensed water has been removed,
replace the rubber plug into the drain hole firmly.
The Full Water indicator should be off now.
7. Replace the drain knob.
8. Turn unit on, the unit will resume working.
Product specificaties
Merk: | Amcor |
Categorie: | Airconditioner |
Model: | ALD12000EH |
Heb je hulp nodig?
Als je hulp nodig hebt met Amcor ALD12000EH stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Airconditioner Amcor
8 September 2022
8 September 2022
8 September 2022
8 September 2022
8 September 2022
8 September 2022
8 September 2022
8 September 2022
8 September 2022
8 September 2022
Handleiding Airconditioner
- Airconditioner Electrolux
- Airconditioner Bosch
- Airconditioner Samsung
- Airconditioner Panasonic
- Airconditioner LG
- Airconditioner AEG
- Airconditioner Bauknecht
- Airconditioner BEKO
- Airconditioner Daewoo
- Airconditioner Honeywell
- Airconditioner Inventum
- Airconditioner Toshiba
- Airconditioner Vaillant
- Airconditioner Whirlpool
- Airconditioner Zanker
- Airconditioner Zibro
- Airconditioner Acson
- Airconditioner Aermec
- Airconditioner Aertesi
- Airconditioner Aircool
- Airconditioner Aircooler
- Airconditioner Airlux
- Airconditioner Airview
- Airconditioner Airwell
- Airconditioner Akai
- Airconditioner Akira
- Airconditioner Alaska
- Airconditioner Alberello
- Airconditioner Andrews
- Airconditioner Argo
- Airconditioner Ariston
- Airconditioner Bryant
- Airconditioner D-Let
- Airconditioner Daikin
- Airconditioner Dimplex
- Airconditioner Domair
- Airconditioner Dometic
- Airconditioner Duux
- Airconditioner Edgestar
- Airconditioner Einhell
- Airconditioner Emerio
- Airconditioner Emmeti
- Airconditioner Eurom
- Airconditioner Fakir
- Airconditioner Frigor
- Airconditioner Fujitsu
- Airconditioner Galanz
- Airconditioner Gutfels
- Airconditioner H.Koenig
- Airconditioner Haier
- Airconditioner Handson
- Airconditioner Heiko
- Airconditioner Innova
- Airconditioner Kenmore
- Airconditioner Klarbach
- Airconditioner Klima1stKlaas
- Airconditioner Koenig
- Airconditioner Maiko
- Airconditioner MDV
- Airconditioner Mizushi
- Airconditioner Mobile Airco
- Airconditioner MPM
- Airconditioner MundoClima
- Airconditioner Qlima
- Airconditioner Qlima - Zibro
- Airconditioner Rowenta
- Airconditioner Shinco
- Airconditioner Sinclair
- Airconditioner SMD
- Airconditioner TechnoLife
- Airconditioner Telair
- Airconditioner Termozeta
- Airconditioner Thermo Comfort
- Airconditioner Tosot
- Airconditioner Trotec
- Airconditioner Ufesa
- Airconditioner Olimpia Splendid
- Airconditioner OneConcept
- Airconditioner Inventor
- Airconditioner Day
- Airconditioner Zymbo
Nieuwste handleidingen voor Airconditioner
18 Maart 2023
5 Februari 2023
5 Februari 2023
5 Februari 2023
2 Januari 2023
5 Februari 2023
4 Januari 2023
2 Januari 2023
8 Maart 2023