Exhaust Fan
BFQ, BFQW Series
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN
THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL
INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock and
injury to person, including the following:
WARNING: TO REDUCE THE RISK
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If you have
questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
WARNING: TO REDUCE THE RISK
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment manufacturer’s guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA) and the American Society for Heating,
Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
CAUTION: FOR GENERAL VENTILATING USE ONLY.
DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS AND VAPORS.
d) Ducted fans must always be vented to the outdoors.
e) This unit must be grounded.
f) To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
g) Read all instructions before installing or using exhaust fan.
WARNING: TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, DO NOT USE THIS FAN WITH
ANY SOLID-STATE SPEED CONTROL DEVICE.
a) If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to a
GFCI (Ground Fault Circuit Interrupter) – protected branch circuit.
b) Do not install wall mounted fans inside the shower area.
WARNING: DO NOT USE IN KITCHENS.
WARNING: THE DUCTING FROM THIS FAN TO THE
OUTSIDE OF THE BUILDING HAS A STRONG EFFECT
ON THE AIR FLOW, NOISE AND ENERGY USE OF THE FAN. USE
THE SHORTEST, STRAIGHTEST DUCT ROUTING POSSIBLE FOR
BEST PERFORMANCE, AND AVOID INSTALLING THE FAN WITH
SMALLER DUCTS THAN RECOMMENDED. INSULATION AROUND
THE DUCTS CAN REDUCE ENERGY LOSS AND INHIBIT MOLD
GROWTH. FANS INSTALLED WITH EXISTING DUCTS MAY NOT
ACHIEVE THEIR RATED AIRFLOW.
INSTALLATION INSTRUCTIONS
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE STARTING INSTALLATION.
SECTION 1
Preparing the Exhaust Fan
1. Unpack fan from the carton and confirm that all pieces are present. In addition to the
exhaust fan you should have:
1 - Grill 1 - Hardware Bag
1 - Damper Assembly (attached) 1 - Electrical Connector
1 - Mounting Bracket 3 - Wire Nuts
1 - Instruction/Safety Sheet
2. Remove the wire compartment cover and store in the carton until needed so it does not
get damaged or lost (Figure 1).
3. Choose the location for your fan. To ensure the best
air and sound performance, it is recommended that
the length of ducting and the number of elbows be
kept to a minimum, the radius of each elbow be as
large as possible for the installation, and that insulated
hard ducting be used. Larger duct sizes will reduce
noise and airflow restrictions.
4. Select the most convenient electrical
knockout and remove using a straight-
blade screw driver (Figure 2).
5. No additional vibration deadening materials are
needed for this fan.
SECTION 2
New Construction - BFQ Models
1. Using the gauge on the mounting bracket, line up the bracket on the joist so the bottom
of the fan will be flush with the finished ceiling. Nail or screw the bracket in place
securely (Figure 3).
WARNING: PROPER INSTALLATION REQUIRES A MINIMUM OF 4
SCREWS LOCATED IN HOLES CLOSEST TO DRYWALL.
2. Snap the fan body into the
bracket The fan can (Figure 4).
be snapped into position with the
duct collar facing to the left or the
right depending which is most
convenient.
www.airkinglimited.com
210572021 Rev. U 11-18 2 of 8
New Construction - BFQW Models (Oval Duct)
1. Using the gauge on the bracket, line up the bracket on the side of a wall stud such that
the bottom of the fan will be flush with the finished wall. The bracket should sit one
drywall thickness forward on the stud (Figure 5).
NOTE: For proper damper operation, the duct
adaptor must be facing up towards the ceiling.
NOTE: ½” minimum thickness drywall must be used for
wall mount applications.
2. Nail or screw the bracket in place securely.
3. Snap the fan body into the bracket, making
sure the duct collar is pointing upwards
towards the ceiling (Figure 6).
SECTION 3
Existing Construction - BFQ Models
1. Position housing against the joist
or stud and trace an outline of
the housing onto the ceiling/wall
material. Set housing aside and cut
opening, being careful not to cut
or damage any electrical or other
hidden utilities (Figure 7).
2. Line up the bracket on the joist so
the bottom of the fan will be flush
with the finished ceiling. Nail or
screw the snap-in bracket in place
securely (Figure 3).
3. Snap the fan body into the bracket The fan can be snapped into position (Figure 4).
with the duct collar facing to the left or the right depending which is most convenient.
Existing Construction - BFQW Models (Oval Duct)
1. Remove a section of the wall material large enough for you to fit the fan housing into as
well as gain access to the top plate, and have enough space to connect the ducting. This
will typically be across two studs and approximately 24" starting at the top of the wall.
2. Follow the instructions in - to Section 2 New Constructions - BFQW Models (Oval Duct)
complete the installation.
NOTE: Wall installation into existing construction will require you to patch the wall material
around the unit.
SECTION 4
Ducting
NOTE: 4" OR LARGER RIGID DUCT IS RECOMMENDED FOR BEST PERFORMANCE.
CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL
BUILDING CODES.
1. Connect the ducting to the fan’s duct
collar Secure in place (Figure 8).
using tape or screw clamp. Always
duct the fan to the outside through a
wall or roof cap. It is recommended
that low restriction termination
fittings be used.
NOTE: For oval duct connection, squeeze
standard 4" round rigid ducting to form
an oval shape then follow instructions in
Step 1.
Figure 2
Figure 4
Figure 1
Figure 6
Figure 3
Figure 5
Drywall Wall Stud
Figure 7
Round duct
collar shown
Figure 8
2. Ensure duct joints and exterior penetrations are sealed with caulk or other similar
material to create an air-tight path to minimize building heat loss or gain and to reduce
the potential for condensation. Place/wrap insulation around duct and/or fan to in order
to minimize possible condensation buildup within the duct, as well as building heat loss
or gain (Figure 9).
SECTION 5
Wiring
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE STARTING INSTALLATION.
CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE
MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR
NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING
ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.
1. Run wiring from an approved wall switch carrying the appropriate rating. One neutral
(white), one ground (green or bare copper), and one hot (black lead connected to
the switch). Secure the electrical wires to the housing with an approved electrical
connector. Make sure you leave enough wiring in the box to make the connection to the
fan’s receptacle.
2. From where you have access to inside the fan’s junction box, connect the White wire
from the house to the White wire from the fan’s receptacle. Connect the Black wire from
the wall switch to the Black wire from the fan’s receptacle. Connect the ground wire
from the house to the Green wire from the fan’s receptacle . Use approved (Figure 10)
methods for all connections.
www.airkinglimited.com
210572021 Rev. U 11-18 3 of 8
SECTION 6
Completing the Installation
1. Use a sealant appropriate for contact with the building materials present and for the
temperature requirements of the installation to prevent air leakage from unconditioned
spaces is recommended. If gaps between unit housing and ceiling are great, additional
material (backing rod, ceiling material) may be required.
NOTE: This fan is rated for direct insulation contact (Type IC) and it is recommended that this fan
be completely covered by insulation in order to reduce heat loss or gain to unconditioned space.
2. Reinstall the fan’s wire compartment cover. Rotate the blower wheel by hand to
ensure it spins freely. Plug the fan’s quick connect motor cord into the receptacle.
This cord will only fit one way into the receptacle (Figure 11).
NOTE: If using this fan to meet ASHRAE 62.2 requirements, locate the label inside the fan
housing and fill in the appropriate information.
3. Install the grill by squeezing the two ends of the springs together and installing them up
into the slots of the fan’s housing. Push the grill up into position (Figure 12).
4. Restore power and test your installation.
SECTION 7
Use and Care
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE SERVICING THE UNIT.
1. Cleaning the Grill: Remove grill and use a mild detergent, such as dishwashing liquid,
and dry with a soft cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS.
Completely dry grill before reinstalling. Refer to instructions in Section 6 Finishing the
Installation, to reinstall grill.
2. Cleaning the Fan Assembly: Unplug the motor cord from receptacle. Wipe all parts
with a dry cloth or gently vacuum the fan. NEVER IMMERSE ELECTRICAL PARTS IN
WATER. Plug the motor cord back in and restore power.
Figure 9
Insulation*
(place around and
over Fan Housing
Fan Housing
Power Cable*
Seal gaps
around Housing
Round
Duct*
Seal duct joints
with tape
Round
Elbows*
Wall Cap*
Roof Cap*
(with built-in
damper)
Keep duct
runs short
*Purchase separately
or
Figure 10
Supply from house
Black
Neutral (White)
Ground (Green or Bare)
Fan
Neutral (White)
Green
Black
By others
Figure 11
Figure 12
Troubleshooting Guide
Trouble Probable Cause Suggested Remedy
1. Fan does not operate when the switch is on. 1a. A fuse may be blown or a circuit tripped. 1a. Replace fuse or reset circuit breaker.
1b. Connector plug from motor is not plugged in. 1b. Turn off power to unit. Remove Grill and plug motor into receptacle
in housing. Restore power to unit.
1c. Wiring is not connected properly. 1c. Turn off power to unit. Check that all wires are connected.
1d Motor has stopped operating. 1d. Replace motor.
2. Fan is operating, but air moves slower than normal. 2. Obstruction in the exhaust ducting. 2. Check for any obstructions in the ducting. The most common are bird
nests in the roof cap or wall cap where the fan exhausts to the outside.
3. Fan is operating louder than normal 3a. Motor is loose. 3a. Turn off power to unit. Remove grill and check that all screws are fully
tightened. Restore power to unit.
3b. Fan blade is hitting housing of unit. 3b. Call your dealer for service.


Product specificaties

Merk: Air King
Categorie: Afzuigkap
Model: BFQ140

Heb je hulp nodig?

Als je hulp nodig hebt met Air King BFQ140 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Afzuigkap Air King

Handleiding Afzuigkap

Nieuwste handleidingen voor Afzuigkap

Miele

Miele DA 6520 D Handleiding

21 November 2024
Miele

Miele DA 420-4 Handleiding

21 November 2024
Miele

Miele DA 2660 Handleiding

21 November 2024
XO

XO R230W Handleiding

21 November 2024
Ilve

Ilve AGK90 Handleiding

20 November 2024
Ilve

Ilve AGQ90 Handleiding

20 November 2024
Ilve

Ilve AGQ60 Handleiding

20 November 2024
Ilve

Ilve AGQ120 Handleiding

20 November 2024
Ilve

Ilve AGK120 Handleiding

20 November 2024