Accucold ARG31PVBIADA-CRT Handleiding

Accucold Koelkast ARG31PVBIADA-CRT

Lees hieronder de 📖 handleiding in het Nederlandse voor Accucold ARG31PVBIADA-CRT (44 pagina's) in de categorie Koelkast. Deze handleiding was nuttig voor 6 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/44
Model:
Serial No.:
Write Model and Serial Numbers
here:
Pharmacy-Medical Controlled Room
Temperature Cabinet
Models
ARS1PV-CRT
ARG1PV- CRT
ARS3PV-CRT
ARG3PV- CRT
ARG31PVBIADA- CRT
ARS32PVBIADA- CRT
ARS6PV-CRT
ARG6PV- CRT
ARG61PVBIADA- CRT
ARS62PVBIADA- CRT
ARS8PV-CRT
ARG8PV- CRT
ARS12PV- CRT
ARG12PV- CRT
ARS15PV- CRT
ARG15PV- CRT
ARS18PV- CRT
ARG18PV- CRT
User Manual
BEFORE USE, PLEASE READ FOLLOW ALL SAFETY RULES OPERATING AND AND
INSTRUCTIONS
Accucold Division of Felix Storch, Inc.
An ISO 9001:2015 registered company
770 Garrison Avenue
Bronx, NY 10474
www.accucold.com
2
EQUIPMENT SAFETY
Your safety and safety others are very important. the of
We have provided many important safety messages this manual and your unit. Always read and in on
obey all safety messages.
This the Safety Alert Symbol. The symbol alerts you to potential hazards is that
can kill injure you and others. All safety messages will follow the Safety or
Alert Symbol and either the words "DANGER" "WARNING". or
DANGER means that failure to heed this safety
statement result severe personal injury may in or
death.
WARNING means that failure heed this safety to
statement may result in extensive product
damage, serious personal injury, death. or
All safety messages will alert you about the potential hazard, tell you how reduce the chance of injury, to
and let you know what can happen if the instructions are followed. not
EQUIPMENT SAFETY
Before the equipment is used, it must be properly positioned and installed as
described in this manual, so read the manual carefully. reduce the risk re, To of
electrical shock or injury when using this equipment, follow basic precautions,
including the following:
Plug into a grounded 3-prong outlet, do not remove grounding prong, do not use an adapter, and do
not use extension cord. an
Replace all panels before operating.
It recommended that a separate circuit serving only your unit provided. Use receptacles that is be
cannot turned by a switch pull chain. be off or
Never clean the equipment parts with ammable uids. These fumes can create a re hazard or
explosion. And store or use gasoline ammable vapors liquids the vicinity do not or other and in of
this any other pieces of equipment. The fumes can create a re hazard explosion. or or
Before proceeding with cleaning and maintenance operations, make sure the power line the unit of is
disconnected.
Do not connect or disconnect electric plug when your hands are wet. the
Unplug the unit disconnect power before cleaning or servicing. Failure or to do so can result in
electrical shock death. or
Do attempt not to repair or replace any part your unit unless specifically recommended this of it is in
manual. All other servicing should referred to a qualied technician. be
These units are CFC- and HFC-free and contains a small quantity of Isobutane (R600a), and the
ARS18PV and ARG18PV are CFC- and HFC-free and contain a small quantity of propane (R290).
Both are environmentally friendly, but ammable. They do not damage the ozone layer, nor do they
increase the greenhouse eect. Care must be taken during transportation and setting up of a unit that
no parts of the cooling system are damaged. Leaking coolant can ignite and damage the eyes. may
In the event of a damage: ny
-
Avoid open ames and anything that creates a spark,
-
Disconnect from the electrical power line,
-
Air the room in which the unit isolated several minutes, for and
3
-
Contact the Service Department for advice.
The more coolant there is in a unit, the larger the room it should be installed in. In the event of a
leakage, the unit a small room, there the danger combustible gases building For every if is in is of up.
ounce of coolant, at least 325 cubic feet of room space is required. The amount of coolant in the unit
is stated on the data plate inside the unit. It is hazardous for anyone other than an Authorized Service
Person carry servicing repairs to this piece equipment. to out or of
Take serious care when handling, moving, and using the unit to avoid either damaging the refrigerant
tubing or increasing risk of a leak. the
Replacing component parts and servicing shall done factory authorized service personnel be by so as
to to minimize the risk possible ignition of due incorrect parts or improper service.
FOLLOW WARNING CALLOUTS BELOW ONLY WHEN APPLICABLE YOUR MODEL TO
Use two or more people move and install . Failure can result in back injury. to unit to do so or other
To ensure proper ventilation for your , the front of the unit must be completely unobstructed. unit
Choose a well-ventilated area with temperatures above 60°F (16°C) and below 90°F (32°C). [For
optimal performance, install the unit where the ambient temperature is between72º and 78ºF (23º-
26ºC).] This unit must installed in area protected from the elements, such wind, rain, water be an as
spray or drips.
The unit should not located next to ovens, grills other sources of high heat. be or
The unit must installed with all electrical, water and drain connections accordance with state be in and
local codes. A standard electrical supply (115 V AC only, 60 Hz), properly grounded in accordance
with the National Electrical Code and local codes and ordinances, required. is
Do kink or pinch power supply cord the unit. not the of
The size of the fuse (or circuit breaker) should be 15 amperes.
It important that the equipment leveled order work properly. You need make several is be in to may to
adjustments level it. to
All installations must accordance with local plumbing code requirements. be in
Make certain that the pipes are pinched, kinked damaged during installation. not or
Check leaks after connection. for
Never allow children operate, play with crawl inside unit. to or the
Do use solvent-based cleaning agents or abrasives the interior. These cleaners damage not on may
or discolor interior. the
Use this equipment only for its intended purpose described this . as in Instruction Manual
Keepngers the areas. Clearances between the door cabinet are necessarily out of pinch point” and
small. careful closing the door when children are in area. Be the
Risk child entrapment! of
Child entrapment suocation are not problems the past. Junked abandoned appliances are and of or
still dangerous, even if will sit the garage a they “just in few days”.
Before discarding your old refrigerator:
Take the doors off
Leave the shelves place children may easily climb inside. in so that not
-SAVE THESE INSTRUCTIONS-


Product specificaties

Merk: Accucold
Categorie: Koelkast
Model: ARG31PVBIADA-CRT

Heb je hulp nodig?

Als je hulp nodig hebt met Accucold ARG31PVBIADA-CRT stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Koelkast Accucold

Handleiding Koelkast

Nieuwste handleidingen voor Koelkast

Hisense

Hisense HRTF206 Handleiding

18 September 2024
Hisense

Hisense HRTF206S Handleiding

18 September 2024
Hisense

Hisense HRTF325 Handleiding

18 September 2024
BEKO

BEKO B5EUNA406HXB Handleiding

18 September 2024
BEKO

BEKO B5RCNA406HXB2 Handleiding

18 September 2024
BEKO

BEKO B5RCNA405HG Handleiding

18 September 2024
Vintec

Vintec V40BVCS3 Handleiding

18 September 2024
Vintec

Vintec V40SG2ES3 Handleiding

18 September 2024
Vintec

Vintec V40SGEBK Handleiding

18 September 2024
Chiq

Chiq CBC094BG Handleiding

18 September 2024