Carat 9690SA-8I-KIT Handleiding

Carat Controller 9690SA-8I-KIT

Lees hieronder de šŸ“– handleiding in het Nederlandse voor Carat 9690SA-8I-KIT (138 pagina's) in de categorie Controller. Deze handleiding was nuttig voor 42 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/138
3wareĀ® SATA+SAS
RAID Controller Card
Command Line Interface
Version 10.2 ā€“ Supports the 9750, 9690SA, and
9650SE Models
PN: 45413-00, Rev. A
May 2010
CLI Guide
Document Description
Document 45413-01, Rev. A. May 2010.
This document will remain the official reference source for all revisions and
releases of this product until rescinded by an update.
Disclaimer
It is the policy of LSI Corporation to improve products as new technology,
components, software, and firmware become available. LSI reserves the right
to make changes to any products herein at any time without notice. All
features, functions, and operations described herein may not be marketed by
LSI in all parts of the world. In some instances, photographs and figures are of
equipment prototypes. Therefore, before using this document, consult your
LSI representative for information that is applicable and current. LSI DOES
NOT ASSUME ANY RESPONSIBILITY OR LIABILITY FOR THE USE
OF ANY PRODUCTS DESCRIBED HEREIN EXCEPT AS EXPRESSLY
AGREED TO IN WRITING BY LSI.
LSI products are not intended for use in life-support appliances, devices, or
systems. Use of any LSI product in such applications without written consent
of the appropriate LSI officer is prohibited.
License Restriction
The purchase or use of an LSI Corporation product does not convey a license
under any patent, copyright, trademark, or other intellectual property right of
LSI or third parties.
Copyright Notice
Ā© 2010 LSI Corporation. All rights reserved.
Trademark Acknowledgments
LSIā„¢, the LSI logo design, 3wareĀ®, 3DMĀ®, 3DM2ā„¢, StorSwitchĀ®, and
TwinStorĀ®, StorSaveā„¢, and StreamFusionā„¢ + are trademarks or registered
trademarks of LSI Corporation.
AppleĀ®, the Apple logo, Mac OSĀ®, and MacintoshĀ® are trademarks of Apple
Computer Inc., registered in the United States and/or other countries.
Sun, Solaris and OpenSolaris are trademarks or registered trademarks of Sun
Microsystems, Inc. in the U.S. and other countries. All other brand and
product names may be trademarks of their respective companies.
www.lsi.com/channel/products iii
Table of Contents
About this CLI Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii
Chapter 1. Introduction to the 3ware Command Line Interface. . . . . . . . . . . . . . . . . .1
Features of the CLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Supported Operating Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Installing the 3ware CLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Installing the 3ware CLI on Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Installing the 3ware CLI on Linux, FreeBSD, OpenSolaris, and VMWare . . . . . . . 3
Installing the 3ware CLI on Mac OS X . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Working with 3ware CLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Using the command interface interactively . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Using a single command with output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Using an input ļ¬le to execute a script . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Outputting the CLI to a Text File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Understanding RAID Levels and Concepts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
RAID Concepts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Available RAID Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Determining Which RAID Level to Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Using Drive Capacity Efficiently . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Chapter 2. CLI Syntax Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Common Tasks Mapped to CLI Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Syntax Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Shell Object Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
focus Object . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
commit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
flush . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
rescan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
show . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
show alarms [reverse] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
show events [reverse] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
show AENs [reverse] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
show diag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
show rebuild . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
show selftest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
show ver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
show verify . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
update fw=filename_with_path [force] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Controller Object Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
/cx show . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
/cx show attribute [attribute ...] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
/cx show achip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
/cx show allunitstatus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
/cx show autocarve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
/cx show autorebuild . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
/cx show bios . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35


Product specificaties

Merk: Carat
Categorie: Controller
Model: 9690SA-8I-KIT
Breedte: 69.3 mm
Diepte: 193 mm
LED-indicatoren: HDD, Status
Certificering: Rohs, FCc, WEEE
Intern geheugen: 512 MB
Intern geheugentype: DDR2
Ondersteunt Windows: Ja
Ondersteunt Mac-besturingssysteem: Ja
Ondersteunt Linux: Ja
Spanning: 12/3.3 V
Kloksnelheid geheugen: 533 MHz
Hostinterface: PCI Express x8
Ondersteunde opslagstationinterfaces: SAS, Serial ATA, Serial ATA II
Beheerprotocollen: 3DM2, I2C
Chipset: I/O RISC
Soorten RAID: 0, 1,5, 6,10, 50, 1E, JBOD
Overdrachtssnelheid: 3 Gbit/s
Stroomverbruik (typisch): 18 W
Bedrijfstemperatuur (T-T): 0 - 50 Ā°C
Hot-swap: Ja
S.M.A.R.T. support: Ja
Number of devices supported: 128
Aantal Internal SATA ports: 8
Interne mini-SAS ports: 2
PCI Card form factor: Half-height (low-profile)
RAID Level Migratie: Ja
Online Capaciteit vergroting: Ja

Heb je hulp nodig?

Als je hulp nodig hebt met Carat 9690SA-8I-KIT stel dan hieronder een vraag en andere gebruikers zullen je antwoorden