Autel PowerScan PS100 Handleiding

Autel Niet gecategoriseerd PowerScan PS100

Lees hieronder de 📖 handleiding in het Nederlandse voor Autel PowerScan PS100 (23 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 221 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/23
Table of Contents
1. SAFETY PRECAUTIONS AND WARNINGS ............................................ 1
2. USING THE TEST TOOL ........................................................................... 2
2.1 T D OOL ESCRIPTION .................................................................................. 2
2.2 S PECIFICATIONS 3.......................................................................................
2.3 A I CCESSORIES NCLUDED ........................................................................... 3
2.4 G D ENERAL ESCRIPTION ............................................................................ 4
2.5 P OWER ..................................................................................................... 4
2.6 Q S -T UICK ELF EST 4....................................................................................
2.7 C IRCUIT REAKERB .................................................................................... 6
2.8 W ORK MODE............................................................................................. 6
3. TEST APPLICATIONS ............................................................................... 9
3.1 V & P T OLTAGE OLARITY ESTING ............................................................... 9
3.2 C T ONTINUITY ESTING ............................................................................... 9
3.3 S C IGNAL IRCUIT ESTINGT ....................................................................... 11
3.4 A C Y H CTIVATING OMPONENTS IN OUR AND ............................................. 12
3.5 T T L C ESTING RAILER IGHTS AND ONNECTIONS ........................................ 13
3.6 A C T V CTIVATING OMPONENTS IN HE EHICLE ........................................... 14
3.7 A C CTIVATING OMPONENTS W/GROUND ................................................... 15
3.8 C HECKING FOR AD ROUND ONTACTSB G C ................................................ 16
3.9 F OLLOWING OCATING HORT IRCUITS& L S C ............................................ 17
3.10 R P ED/GREEN OLARITY LED ................................................................... 18
4. TEST TOOL SPECIFICATIONS .............................................................. 19
5. TEST TOOL KNOW- HOW ...................................................................... 20
6. WARRANTY AND SERVICE 22 ...................................................................
6.1 L IMITED NE EAR ARRANTYO Y W ............................................................. 22
6.2 S P ERVICE ROCEDURES ............................................................................ 22
1
1. Safety Precautions and Warnings
To prevent personal injury or damage to vehicles and/or the test
tool, read this instruction manual rst and observe the following
safety precautions at a minimum whenever working on a vehicle:
Always perform automotive testing in a safe environment.
Wear safety eye protection that meets ANSI standards.
Keep clothing, hair, hands, tools, test equipment, etc. away from
all moving or hot engine parts.
Operate the vehicle in a well ventilated work area: Exhaust gases
are poisonous.
Put blocks in front of the drive wheels and never leave the vehicle
unattended while running tests.
Use extreme caution when working around the ignition coil,
distributor cap, ignition wires and spark plugs. These
components create hazardous voltages when the engine is
running.
Put the transmission in PARK (for automatic transmission) or
NEUTRAL (for manual transmission) and make sure the parking
brake is engaged.
Keep a re extinguisher suitable for gasoline/chemical/ electrical
res nearby.
Don’t connect or disconnect any test equipment while the
ignition is on or the engine is running.
Keep the tool dry, clean, free from oil/water or grease. Use a mild
detergent on a clean cloth to clean the outside of the test tool,
when necessary.
When the power switch in the tool is depressed battery
current/voltage is conducted directly to the tip which may cause
sparks when contacting ground or certain circuits. Therefore the
tool should NOT be used around ammables such as gasoline or
its vapors. The spark of an energized tool could ignite these
vapors. Use the same caution as you would when using an arc
welder.
2
2. Using the Test Tool
2.1 ol Description To
Probe Tip Contacts the circuit or component to be tested.
Head Lights Illuminates dark work areas or work areas at
night. .
Red/Green Polarity Indicator Identies positive, negative or
open circuits. The RED Indicator lights when the Probe Tip is


Product specificaties

Merk: Autel
Categorie: Niet gecategoriseerd
Model: PowerScan PS100

Heb je hulp nodig?

Als je hulp nodig hebt met Autel PowerScan PS100 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Autel

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd